- CA37RT
ABB CA37RT is an industrial catalog item. Key specifications include Standards: DIN EN 61439-3, Rated Operational Voltage: Maximum 400 V, Operational Voltage: 400 V, and Rated Current (I n ): 125 A. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- CA37VML
ABB CA37VML compact distribution board, manufacturer ID 2CPX052218R9999. Surface-mounting steel enclosure with powder-coated traffic white (RAL 9016) finish, closed single door with turn-handle closure. Rated operational voltage 400 V maximum; rated current 125 A. Seven rows provide 168 DIN place units. Configuration: assembled with distribution module and multimedia module. Quick-Terminal terminals. Degree of protection IP30. Power loss: 80.6 W at Δt = 20 K, 106.4 W at Δt = 25 K, 125.7 W at Δt = 30 K. Standards: DIN EN 61439-3.
- CA38B
ABB CA38B compact distribution board, manufacturer ID 2CPX052177R9999. This surface-mounting enclosure is pre-assembled for installation of modules and CombiLine Modules, with 8 rows and 288 DIN place units. It is rated 125 A at a maximum rated operational voltage of 400 V, to DIN EN 61439-3. Power loss is 93.8 W at Δt = 20K, 123.9 W at Δt = 25K, and 146.3 W at Δt = 30K. The steel housing is powder-coated in traffic white (RAL 9016), closed, without door, with optional cover plate and no terminals. Degree of protection IP30; protection class isolated (Class II).
- CA38R
ABB CA38R compact distribution board, manufacturer ID 2CPX052244R9999. Rated operational voltage maximum 400 V; rated current 125 A. Standards: DIN EN 61439-3. Power loss: 93.8 W at Δt = 20K, 123.9 W at Δt = 25K, 146.3 W at Δt = 30K. Seven rows, 252 DIN place units. Steel housing, powder-coated traffic white (RAL 9016), closed door with double-leaf cover plate and turn-handle closure. Surface mounting, IP44 degree of protection, quick-terminal connections. Supplied assembled with distribution module.
- CA38RT
ABB CA38RT is an industrial catalog item. Key specifications include Standards: DIN EN 61439-3, Rated Operational Voltage: Maximum 400 V, Operational Voltage: 400 V, and Rated Current (I n ): 125 A. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- CA38V
ABB CA38V compact distribution board, manufacturer ID 2CPX052194R9999. Surface-mount steel enclosure with powder-coated traffic white (RAL 9016) finish, closed double door, and turn-handle closure. Rated operational voltage 400 V maximum; rated current (In) 125 A. Eight rows provide 288 DIN place units. Supplied assembled with a distribution module and quick terminals. Power loss: 93.8 W at Δt = 20 K, 123.9 W at Δt = 25 K, 146.3 W at Δt = 30 K. Degree of protection IP44. Standards: DIN EN 61439-3.
- CA4-01
ABB CA4-01 auxiliary contact block, manufacturer ID 1SBN010110R1001. It is a front-mounted, 1-pole auxiliary contact block with one NC instantaneous contact and no NO contacts. Screw terminals accept flexible conductors with ferrule from 0.75 to 2.5 mm² and rigid conductors; wire stripping length is 10 mm. Dimensions are 9.9 mm wide, 39.5 mm deep, and 43 mm high; net weight is 0.014 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with conventional free-air thermal current 16 A at 40 °C per IEC 60947-5-1. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-01-T
ABB CA4-01-T auxiliary contact block, front mounted, with one normally closed (NC) auxiliary contact and screw terminals. Dimensions are 9.9 mm wide, 39.5 mm deep, and 43 mm high; net weight is 0.014 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and rated impulse withstand voltage 6 kV. It is declared suitable for AF09 through AF96, AFC09 through AFC96, corresponding B variants, and NF22E through NF40E contactors. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.