- HVL12-6-5-DC24V
CKD HVL12-6-5-DC24V solenoid valve for vacuum service. Port A connection is Rc1/8, and the coil operates at 24 VDC. Dimensions: A 78 mm, B 11.5 mm, C 28 mm, D 76 mm, E 51 mm, F 14.5 mm. The valve is supplied under model designation HVL.
- HVB612-12F-8B-AC100V
CKD solenoid valve for vacuum service, model HVB612-12F-8B-AC100V. Configuration: size variation 6 (60 mm), flange connection 12F (φ 48), orifice size 8 (φ 8), thermal class B (Class 130), no option, and AC 100 V 50/60 Hz coil. Dimensions: A 60 mm, B 117 mm, C 52.0 mm, D 49 mm, E 40.0 mm, F 4-M4 mm, G 101 mm, H 70 mm, J 48 mm, K 32 mm, L 77 mm. The valve uses a direct acting poppet structure. Leakage rate is 1.0 x 10^-9 Pa·m³/s or less. Five coil sizes and multiple orifice sizes are available. Connection options include VCR fittings and double barbed fittings.
- HVB512-4RM-5-2CR-AC100V
CKD HVB512-4RM-5-2CR-AC100V is a solenoid valve for vacuum service. The model number is HVB512. It has a 1/4" JXR male fitting connection and an orifice size of φ4.5. The 2CR option denotes a grommet lead wire with all wave rectifier. The coil is rated 100 VAC 50/60 Hz and 110 VAC 60 Hz. Dimensions A and B are 37.5 mm and 40 mm respectively. The size variation is listed as 5: 40 mmmm. No leakage rate, pressure range, or application suitability is stated in the supplied data.
- HVB412-4RM-3-2CR-AC100V
The CKD HVB412-4RM-3-2CR-AC100V is a solenoid valve for vacuum service. It has a direct acting poppet structure. The connection is a 1/4" JXR male fitting, and the orifice size is φ 3. The valve seat leakage and external leakage are each 1.0 x 10^-9 Pa·m³/s (He). The coil is rated for 100 VAC 50/60 Hz and 110 VAC 60 Hz, and it is fitted with a grommet lead wire with a full-wave rectifier. Dimensions A and B are 34 mm. The valve is rated for up to 2 million cycles.
- HVB312-4RM-2-2CR-AC100V
CKD solenoid valve HVB312-4RM-2-2CR-AC100V, for vacuum service. Connection is a 1/4" JXR male fitting; orifice size is φ2. The 2CR option denotes a grommet lead wire with all-wave rectifier. Coil rating is 100 VAC 50/60 Hz or 110 VAC 60 Hz. Dimensions A and B are 29.5 mm and 28 mm respectively; dimensions C through L are not specified. The size variation field lists "3 : 28 mmmm" and is not restated here. No operating pressure range, leak rate, body or diaphragm material, fitting compatibility, or service life is supplied in the authoritative parameters, so none is stated.
- HVB212-4RM-Z-2CR-AC100V
CKD HVB212 solenoid valve for vacuum service, model HVB212-4RM-Z-2CR-AC100V. Connection: 1/4" JXR male fitting. Orifice size: φ1. Coil rated 100 VAC 50/60 Hz and 110 VAC 60 Hz, with grommet lead wire and all-wave rectifier. Dimensions A 26.5 mm and B 22 mm. Size variation 2 corresponds to 22 mm.
- HVB112-6N-5-AC100V
The CKD HVB112-6N-5-AC100V is a solenoid valve for vacuum service. It has an NPT1/8 port size and a φ1.6 orifice. The coil operates at 100 VAC, 50/60 Hz. The valve is intended for high vacuum applications.