- SHD3100-G04-20-E1-AC100V
CKD air dryer, model SHD3100-G04-20-E1-AC100V. Flow rate classification 100: 10 m3/min (ANR). Equipped with a temperature and humidity sensor (G). Inlet air pressure 04: 0.4 MPa. Outlet pressure dew point 20: -20°C. Filter option E1: without accessory filter. Voltage AC100V: 100 VAC. Port size Rc1 1/2. Dimensions: A 845 mm, B 1559 mm, C 360 mm, D 20 mm, E 1163 mm, F 585 mm, G 320 mm, H φ12 mm, I 213 mm, J 266.5 mm, K 153.5 mm, L 683 mm, M 100 mm. Voltage specification, English text, and bolt nut options are blank (none).
- SHD3125-G04-20-E1-AC100V
The CKD SHD3 series air dryer, model SHD3125-G04-20-E1-AC100V, has a flow rate classification of 12.5 m3/min (ANR) and an inlet air pressure of 0.4 MPa. It achieves an outlet pressure dew point of -20°C. The unit includes a temperature and humidity sensor and is configured without an accessory filter. It operates on 100 VAC and has an RC2 port size.
- SHD3150-G04-20-E1-AC100V
CKD air dryer, model SHD3150-G04-20-E1-AC100V. Flow rate classification 150: 15 m3/min (ANR). Temperature and humidity sensor. Inlet air pressure 0.4 MPa. Outlet pressure dew point -20°C. Without accessory filter. Voltage 100 VAC. Port size RC2. Dimensions: A 1145 mm, B 1589 mm, C 360 mm, D 20 mm, E 1193 mm, F 700 mm, G 330 mm, H φ15 mm, I 213 mm, J 296.5 mm, K 153.5 mm, L 683 mm, M 100 mm. The legacy description identifies this item as a power supply unit, which conflicts with the authoritative category of air dryers; that description and its efficiency, voltage-stability, and standards claims are omitted.
- SHD3200-G04-20-E1-AC100V
CKD SHD3200-G04-20-E1-AC100V air dryer. Flow rate classification 200: 20 m3/min (ANR). Inlet air pressure 04: 0.4 MPa. Outlet pressure dew point 20: -20°C. Equipped with G: temperature and humidity sensor. Filter option E1: without accessory filter. Voltage AC100V: 100 VAC. Port size Rc2 1/2. Dimensions: A 1445mm, B 1589mm, C 360mm, D 20mm, E 1193mm, F 780mm, G 330mm, H φ15mm, I 213mm, J 296.5mm, K 153.5mm, L 810mm, M 120mm. Voltage specification, English text, and bolt nut options are blank (none).
- SHD3240-G04-20-E1-AC100V
CKD air dryer, display model SHD3240-G04-20-E1-AC100V. Flow rate classification 240 corresponds to 24 m3/min (ANR). Inlet air pressure 0.4 MPa; outlet pressure dew point -20°C. Equipped with a temperature and humidity sensor (G). Filter option E1 indicates without accessory filter. Voltage AC100V, 100 VAC. Port size Rc2 1/2. Dimensions: A 1745 mm, B 1589 mm, C 360 mm, D 20 mm, E 1193 mm, F 780 mm, G 330 mm, H φ15 mm, I 213 mm, J 296.5 mm, K 153.5 mm, L 810 mm, M 120 mm. Voltage specification, English text, and bolt nut options are blank (none). The model no. field lists SHD3.
- SU3015-A05-W
CKD SU3015-A05-W air dryer. The model designation SU3015 specifies an outlet air atmospheric dew point of -20°C (code A) and an inlet air pressure of 0.5 MPa (code 05). The W suffix is not defined by the supplied data. The unit uses a high polymer membrane for non-electric operation without F-gas. Dimensions: A 337 mm, B 193 mm, C 308 mm, D 63 mm, E 211 mm, F 45 mm, G 85 mm. No common exhaust or reversed inlet and outlet options are indicated. No flow capacity, operating temperature range, connection size, or certification is supplied.
- SU301D-05-W-C1
The CKD SU301D-05-W-C1 is an air dryer with a 0.5 MPa inlet air pressure rating. It measures 63 x 63 x 175 mm and has a dew point of -20°C. The unit uses a maintenance design with replaceable components. Dimensions A through F are 143 mm, 171 mm, 226 mm, 80 mm, 55 mm, and 97 mm respectively.
- SU301E-05-W-C1
CKD SU301E-05-W-C1 air dryer. The model number indicates an inlet air pressure of 0.5 MPa, and the unit type is C1. Dimensions are A 126 mm, B 153 mm, C 208 mm, D 63 mm, E 45 mm, F 79.0 mm, and G 0.0 mm. No common exhaust or reversed inlet and outlet options are specified. The supplied reference text describes a high polymer membrane dryer with a -60°C dew point and a 10% purge rate, but this information is not confirmed by the structured parameters and should be verified against the manufacturer's data before use.