- VSC-H12-6A8LS
CKD VSC-H12-6A8LS ejector system. Nozzle diameter 1.2 mm; ultimate vacuum 93 kPa; suction flow 38 l/min; air consumption 70 l/min. Port R is R1/8. Dimensions: A 8 mm, D1 8 mm, L1 45.7 mm, L2 41.7 mm, L3 16 mm, P1 14.5 mm, P2 16 mm, E1 58.3 mm, E2 20.3 mm, C 18.1 mm, F 16 mm, opposite side 14 mm. Weight 34 g. Parameters listed as "-" are not specified. The legacy text describes a VSC series with nozzle diameters 0.5 to 2.0 mm and intake flow rates 7 to 180 L/min (ANR); those series-wide figures are not confirmed for this model.
- VSC-H12-6A8S
CKD VSC-H12-6A8S ejector system. Structured parameters: nozzle diameter 1.2 mm; ultimate vacuum 93 kPa; suction flow 38 l/min; air consumption 70 l/min; weight 31.5 g. Port A 8 mm, port D 8 mm, port R R1/8. Dimensions: L1 28 mm, L2 24 mm, L3 16 mm, P 16 mm, B 65.2 mm, E 27.2 mm, C 18.2 mm, F 16 mm. Parameters M, D1, D2, P1, P2, E1, E2, C1, C2, and opposite side are listed as not applicable. The legacy description states a 6 mm nozzle diameter and an 8 mm vacuum port; the 6 mm nozzle value conflicts with the structured nozzle diameter of 1.2 mm and is omitted. No order code or manufacturer part number is supplied.
- VSC-H15-10A10J
The CKD VSC-H15-10A10J is an ejector system with a 1.5mm nozzle diameter. It achieves an ultimate vacuum of 93kPa, a suction flow of 63l/min, and an air consumption of 100l/min. Its port is R3/8. Dimensional data include A 12mm, D1 10mm, D2 12mm, L1 38mm, L2 31.7mm, L3 20.7mm, P 22mm, B 95.7mm, E 30.9mm, C1 20.7mm, C2 23.3mm, and F 22mm. Weight is 100.5g. Values shown as "-mm" are not specified. The product is an ejector system for vacuum generation; no application, certification, or accessory information is supplied.
- VSC-H15-10A10LJ
CKD VSC-H15-10A10LJ ejector system. Dimensions: A 12 mm, D1 10 mm, D2 12 mm, R R3/8 mm, L1 56.5 mm, L2 50.2 mm, L3 20.7 mm, P1 17.5 mm. The unit uses a controlled air supply through a defined nozzle diameter.
- VSC-H15-10A10LS
CKD VSC-H15-10A10LS ejector system. The nozzle diameter is 1.5 mm. Ultimate vacuum is 93 kPa; suction flow is 63 l/min; air consumption is 100 l/min. The air supply port is R3/8. Dimensions include A 12 mm, D1 10 mm, L1 56.5 mm, L2 50.2 mm, L3 20.7 mm, P1 17.5 mm, P2 24 mm, E1 100.8 mm, E2 25.8 mm, C 20.2 mm, opposite side 19 mm, and F 22 mm. Weight is 91.5 g. Values shown as "-mm" are not supplied. The legacy description's 1.5-inch nozzle and 10-inch air supply port conflict with the structured parameters and are omitted.
- VSC-H15-10A10S
The CKD VSC-H15-10A10S is a vacuum ejector system with a 1.5mm nozzle diameter. It produces an ultimate vacuum of 93kPa, a suction flow of 63l/min, and consumes 100l/min of air. The unit weighs 89g. Dimensional data include A 12mm, D 10mm, L1 39mm, L2 32.7mm, L3 20.7mm, P 24mm, B 105.9mm, E 30.9mm, C 20.7mm, and F 22mm. The port is R3/8. The model number is VSC-H15-10A10S. No electrical rating, operating temperature range, standard, certification, or application is specified in the supplied data.
- VSC-H15-10A8J
CKD VSC-H15-10A8J ejector system. Dimensions: A 12 mm, D1 8 mm, D2 12 mm, L1 38 mm, L2 31.7 mm, L3 20.7 mm, P 22 mm, B 94 mm, E 29.2 mm, C1 18.2 mm, C2 23.3 mm, F 22 mm. Connection R is R3/8. Nozzle diameter is 1.5 mm. Ultimate vacuum is 93 kPa. Suction flow is 63 l/min. Air consumption is 100 l/min. Weight is 99.5 g. M, D, P1, P2, E1, E2, C, and opposite side are not specified. The legacy description's claims of high-performance construction, precise control, and energy efficiency are not supported by the supplied parameters and are omitted.
- VSC-H15-10A8LJ
CKD VSC-H15-10A8LJ ejector system. Structured parameters: nozzle diameter 1.5 mm; R dimension R3/8 mm; ultimate vacuum 93 kPa; suction flow 63 l/min; air consumption 100 l/min; weight 98.5 g. Dimensions include A 12 mm, D1 8 mm, D2 12 mm, L1 52.7 mm, L2 46.4 mm, L3 20.7 mm, P1 14.5 mm, P2 22 mm, E1 88.1 mm, E2 23.3 mm, C1 18.2 mm, C2 23.3 mm, F 22 mm, and opposite side 19 mm. Parameters M, D, P, B, E, and C are listed as "-mm" and are not stated. The legacy description's "high vacuum/medium flow" wording and application claims are not repeated.