- SC3U-15-10
CKD SC3U-15-10 speed control valve with R1/2 port size and Ø10 mm applicable tube outside diameter. Meter-out configuration. The piping direction is adjustable through 360°. Body dimensions include 59.1 mm knob position, 15.0 mm A, 33.8 mm B, 27.0 mm D, 16 mm E, 17.5 mm F, 23.3 mm G, and 32.1 mm H. Constructed with flame-resistant resin and a coated piping screw.
- SC3U-6-4
CKD SC3U-6-4 is a speed control valve in the SC3U series with a meter-out configuration (blank option). It accepts a Ø4 mm tube and has an R1/8 port size. The knob is positioned at 33.4 mm, and the tube insertion length is 16.0 mm. Dimensional data include A 8.0 mm, B 15.4 mm, D 14.5 mm, E 9 mm, F 10.0 mm, G 14.5 mm, H 19.5 mm, I 39.0 mm, J 13.0 mm, and L 13 mm. The legacy description states a 270 l/min flow rate, 360° piping direction adjustment, flame-retardant PBT resin, 0.05 to 1 MPa operating pressure, and 0 to 60°C temperature range; these values are not confirmed by the structured parameters and are provided for reference only.
- SC3U-8-6
The CKD SC3U-8-6 is a speed control valve in the SC3U series with an R1/4 port size and a Ø6 mm applicable tube outside diameter. The blank option indicates meter-out configuration. Dimensional data include a knob position of 46.1 mm, tube insertion length of 17.5 mm, and dimensions A 11.0 mm, B 24.9 mm, D 19.0 mm, E 12 mm, F 12.5 mm, G 17.3 mm, H 23.6 mm, I 50.5 mm, J 13.8 mm, and L 17 mm. No flow rate, operating pressure range, material, or certification is specified in the supplied parameters.
- SC3U-M3-3
The CKD SC3U-M3-3 is a meter-out speed control valve for compressed air systems. It has an M3 x 0.5 port and accepts tubing with a 3.2 mm outside diameter. The knob is positioned at 26 mm, and the tube insertion length is 12.5 mm. Dimensional references are A 2.4 mm, B 11.4 mm, D 7.4 mm, E 5 mm, F 8.5 mm, G 10.0 mm, H 14.3 mm, I 28.9 mm, J 9.8 mm, and L 7 mm. The valve provides adjustable flow for fine speed adjustment of pneumatic actuators.
- SC3U-M5-3
CKD SC3U-M5-3 speed control valve with meter-out configuration. Port size M5 x 0.8; applicable tube outer diameter Ø3.2 mm; tube insertion length 12.5 mm. Knob position 27.8 mm. Dimensions: A 3.4 mm, B 12.4 mm, D 9.6 mm, E 6 mm, F 8.5 mm, G 11.1 mm, H 15.4 mm, I 30.0 mm, J 9.8 mm, L 8 mm. The body uses flame-resistant PBT and the port threads carry a fluorine-based resin sealant. Piping direction can be set at any angle up to 360°. For compressed air service, working pressure range 0.05 MPa to 1.0 MPa.
- SC3W-10-6
CKD SC3W-10-6 speed control valve, meter-out configuration, for pneumatic flow control. Port size 10 corresponds to R3/8 thread; applicable tube outside diameter is 6 mm (Ø6 mm). Dimensions: A 52.4 mm, B 23.1 mm, C 12 mm, D 11.3 mm, E 28.3 mm, F 14.0 mm, G 12.5 mm, opposite side of hexagon 19 mm. CMAX and CMIN are both 0.0 mm, and tube insertion length is 0.0 mm. The body uses flame-resistant material equivalent to UL94 V-0. The push-in fitting permits adjustment of piping direction.
- SC3W-15-10
CKD SC3W-15-10 speed control valve with meter-out configuration. Port size 15 is R1/2 thread, suitable for Ø10 mm tube outer diameter. Dimensions: A 66.7 mm, B 33.8 mm, C 15 mm, D 13.5 mm, E 34.5 mm, CMAX 0.0 mm, CMIN 0.0 mm. The elbow body permits flexible piping direction and uses a quick-connect fitting.
- SC3W-6-4
The CKD SC3W-6-4 is a one-touch speed controller for compressed air, configured as meter-out. It has an R1/8 port thread and accepts 4 mm outside-diameter tubing. Dimensions include A 38.4 mm, B 16.2 mm, C 8 mm, D 7.3 mm, E 23.1 mm, F 9.0 mm, G 10.0 mm, and a hexagon across flats of 13 mm. The legacy description states a working pressure range of 0.05 MPa to 1.0 MPa, a proof pressure of 1.5 MPa, and an operating temperature range of 5°C to 60°C; these values are not confirmed by the structured parameters.