- C6060-20-W
CKD C6060-20-W is a modular F.R.L. combination with a 3/4 port size and Rc thread. The unit has a 5 μm filter element and a polycarbonate bowl with manual drain cock. Flow direction is standard, left to right. It has no differential pressure detection port. The displayed unit is MPa for Rc thread. A pipe adaptor set is not included, and no adaptor thread is specified. The model number is C6060-20-W. This description is limited to the supplied configuration data.
- C6070-20-W
The CKD C6070-20-W is an F.R.L. combination with a 3/4 port size and Rc thread. It accepts an F6000 air filter rated at 5 μm or 0.3 μm, or an M6000 oil mist filter. The unit has a polycarbonate bowl and a manual drain cock. It has no differential pressure detection port and no piping adaptor set attached. Flow direction is standard, left to right. The displayed unit is MPa for Rc thread. The model number is C6070; the suffix 20 denotes the 3/4 port size.
- C6500-20-W
CKD C6500-20-W F.R.L. combination. Configured with air filter F6000, regulator R6000, and lubricator L8000. Port size 20 corresponds to 3/4, with Rc thread. Pressure range 0.05 to 0.85 MPa. The regulator has a relief mechanism. Filtration element rating is 5 μm. Bowl material is polycarbonate. Drainage is via manual drain cock; the lubricator has no drain cock. A standard pressure gauge (G401-W) is fitted. Flow direction is standard, left to right. No differential pressure detection port, distributor, pressure switch, shut-off or lockout valve, piping adaptor set, or additional attachment is included. Displayed unit is MPa for Rc thread.
- C6500-20-W-TP6
The CKD C6500-20-W-TP6 is an F.R.L. combination consisting of an F6000 air filter, R6000 regulator, and L8000 lubricator. It has a 3/4 port size with Rc thread. The lubricator has no drain cock, and the bowl is polycarbonate. Filtration is 5 μm. The pressure range is 0.05 to 0.85 MPa, with a relief mechanism. No differential pressure detection port is provided.
- C8000-20-W
CKD C8000-20-W F.R.L. combination for compressed air, comprising air filter F8000, regulator R8000, and lubricator L8000. Port size 20 corresponds to 3/4 with Rc thread. The filter element is 5μm. The regulator pressure range is 0.05 to 0.85 MPa, with relief mechanism. The unit has a polycarbonate bowl, manual drain cock, and the lubricator has no drain cock. A standard pressure gauge G401-W is fitted, and the displayed unit is MPa for Rc thread. Standard flow direction is left to right. No differential pressure detection port, distributor, pressure switch, shut-off or lockout valve, piping adaptor set, or other attachments are included.
- C8000-20-W-TP6
The CKD C8000-20-W-TP6 is a modular F.R.L. combination for compressed air, comprising the F8000 air filter, R8000 regulator, and L8000 lubricator. It has a 3/4 port size with Rc thread, a polycarbonate bowl, and a 5 µm filter element. The lubricator has no drain cock. Operating pressure range is 0.05 to 0.85 MPa, and the unit includes a relief mechanism. No pressure gauge is fitted; the gauge port (Rc1/4) is assembled sealed. Flow direction is standard, left to right. The displayed unit is MPa. No piping adaptor set or other attachment is included. No differential pressure detection port is provided.
- C8000-J800-W
CKD C8000-J800-W is listed in the F.R.L. combinations category. Key specifications include Model No.: C8000-J800-W, Applicable model: 6000 / 8000 Series, A: 26mm, and B: 65mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- C8010-20-W
The CKD C8010-20-W is an F.R.L. combination comprising a W8000 filter/regulator and an L8000 lubricator. It has a 3/4 port size with Rc thread, a polycarbonate bowl, and a 5μm element. The pressure range is 0.05 to 0.85 MPa, and the unit includes a relief mechanism. A standard pressure gauge (G401-W) is fitted, and the displayed unit is MPa for Rc thread. The filter/regulator has a manual drain cock; the lubricator has no drain cock. Flow direction is standard, left to right. No pressure switch, shut-off or lockout valve, piping adaptor set, or attachment gauge is included.