- 756-1301/060-050
WAGO shielded circular cable assembly, model 756-1301/060-050, with an M12 socket to free end connection, 5 poles, B-coded, 0° cable-to-mating direction, and 5 m cable length. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. Contact resistance is 10 mΩ; conductor resistance is ≤ 145 Ω/km. The cable uses type KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid, optical coverage approx. 65 %. Housing is TPU/TPU, black (~ RAL 9005); contacts are CuZn with CuNi/Au plating. Protection type is IP67, ambient operating temperature is -25 … +60 °C, maximum mating cycles are 100, and tightening torque is 1 Nm. Weight is 215 g.
- 756-1301/060-200
WAGO 756-1301/060-200 is a shielded system bus cable with an M12 socket to free end connection, 5-pole, B-coded, 0° cable-to-mating direction, and 20 m length. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. Contact resistance is 10 mΩ and conductor resistance is ≤ 145 Ω/km. The cable uses a KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω shielded type code with aluminum-laminated foil and tinned copper braid, approximately 65 % optical coverage. Housing is TPU/TPU, black (~ RAL 9005). Protection type is IP67, ambient operating temperature is -25 … +60 °C, and maximum mating cycles are 100.
- 756-1302/060-020
WAGO 756-1302/060-020 is a shielded system bus cable, 2 m long, with a 5-pole B-coded M12 socket at 90° to the mating direction and a free end. It is rated 60 V and 4 A, with 1.5 kV rated surge voltage per IEC 61076-2-101, contact resistance 10 mΩ, and conductor resistance ≤ 145 Ω/km. The cable uses KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω construction with bare copper conductors and aluminum-laminated foil plus tinned copper braid shielding at approximately 65 % optical coverage. The housing is black TPU/TPU; contacts are CuZn with CuNi/Au plating. Protection type is IP67, operating ambient temperature -25 to +60 °C, maximum 100 mating cycles, tightening torque 1 Nm, weight 98 g.
- 756-1302/060-050
WAGO 756-1302/060-050 is a shielded system bus cable with an M12 socket, B-coded, 5-pole, to a free end. The cable connection is angled 90° to the mating direction, with a 5 m length. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. The cable type is KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid at approximately 65 % optical coverage. Contacts are CuZn with CuNi/Au plating. Protection type is IP67; ambient operating temperature is -25 to +60 °C. Maximum mating cycles are 100 at 1 Nm tightening torque. Weight is 197 g.
- 756-1302/060-100
WAGO 756-1302/060-100 is a shielded system bus cable with a 5-pole, B-coded M12 socket at a 90° angle to the mating direction and a free end. Cable length is 10 m. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. The cable type is KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid at approximately 65 % optical coverage. Conductors are bare copper (26/7 AWG). Housing is TPU/TPU, black (~ RAL 9005); contacts are CuZn with CuNi/Au plating. Protection type is IP67; ambient operating temperature is -25 to +60 °C. Maximum mating cycles are 100; tightening torque is 1 Nm. Weight is 401 g.
- 756-1303/060-050
WAGO 756-1303/060-050 system bus cable, 5 m, with 5-pole B-coded M12 plug to free end, straight (0°) connection direction. Operating voltage 60 V, operating current 4 A, rated surge voltage 1.5 kV per IEC 61076-2-101, contact resistance 10 mΩ, conductor resistance ≤ 145 Ω/km. Shielded cable type KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω with aluminum-laminated foil and tinned copper braid, approx. 65 % optical coverage. TPU housing, black; CuZn contacts with CuNi/Au plating; FPM sealing ring. IP67, ambient temperature -25 to +60 °C, max. 100 mating cycles, tightening torque 1 Nm, weight 212 g. RoHS compliant with exemption 6(c). End of sale 2024-05-01.
- 756-1304/060-020
WAGO 756-1304/060-020 is a shielded system bus cable accessory with an M12 B-coded 5-pole plug at one end and a free end. The plug exits at 90° to the mating direction. Cable length is 2 m; the cable is yellow and uses the type code KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid shielding at approximately 65 % optical coverage. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. Contacts are CuZn with CuNi/Au plating. Housing is TPU/TPU, black (~ RAL 9005). Protection type is IP67. Ambient operating temperature is -25 … +60 °CK. Maximum mating cycles are 100; tightening torque is 1 Nm. Weight is 102 g. Pollution degree is 3/2 per IEC 60664-1.
- 756-1304/060-050
WAGO 756-1304/060-050 system bus cable with M12 plug to free end, 5-pole, B-coded, 90° cable connection direction to mating direction, 5 m length. Operating voltage 60 V, operating current 4 A, rated surge voltage 1.5 kV per IEC 61076-2-101, contact resistance 10 mΩ, conductor resistance ≤ 145 Ω/km. Shielded construction: aluminum-laminated foil and tinned copper braid, optical coverage approx. 65 %. Housing TPU/TPU, black (~ RAL 9005); contacts CuZn with CuNi/Au plating. Ambient operating temperature -25 … +60 °C, protection type IP67, pollution degree 3/2 per IEC 60664-1. Maximum mating cycles 100, tightening torque 1 Nm, weight 219 g. RoHS compliant with exemption 6(c). End of sale 2024-05-01; end of production 2024-05-15; end of delivery 2024-06-01.