Industrial Automation Parts. Prompt replies from real people.

WAGO 765-4201/100-000 8-Port IO-Link Master Class A

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/27/2026

Q1Can you supply the WAGO 765-4201/100-000?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 765-4201/100-000 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
765-4201/100-000
Material Number
—
Manufacturer
WAGO
Product ID
50054

Get a Free Quote

Request pricing and availability for 765-4201/100-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
670g
Ambient temperature (operation)
-25 … +70 °C
Protection type
IP67
Overvoltage category
II (EN 60664-1)
Output current (per channel)
2 A (typ.) for DO
Supply voltage
24 VDC (18 … 31.2 V); 1L
See all specifications

Product Highlights

  1. Fieldbus Interface: EtherCAT with 2 x D-coded M12 4-pole ports, 10BASE-T/100BASE-TX, potential-free, autonegotiation and autocrossover
  2. I/O Configuration: 16 digital inputs and 16 digital outputs via 8 x A-coded M12 5-pole connections, 24 VDC, Type 3 input per IEC 61131-2, 2 A typical output current per DO channel
  3. IO-Link Master: Class A, V1.1 specification, minimum cycle time 400 µs, port modes autoconfig, manual and tool-based, pin 4 and pin 2 adjustable as DI or DO per port
  4. Supply: 24 VDC (18 to 31.2 V) via 2 x L-coded M12 5-pole connections, maximum current consumption 16000 mA per supply line, overload and short-circuit protected with reverse voltage protection
  5. Environmental and Mechanical Ratings: IP67, protection class III per EN 61140, IEC 61140 and VDE 0140-1, operating temperature -25 to +70 °C, storage temperature -40 to +80 °C, 95% relative humidity without condensation, operating altitude 0 to 2000 m, pollution degree 3 and overvoltage category II per EN 60664-1
  6. Vibration and Shock Resistance: 5g per IEC 60068-2-6, short-term shock 50g/11 ms half-sine per IEC 60068-2-27 and long-term shock 30g/6 ms half-sine per IEC 60068-2-29
  7. EMC: immunity to interference per EN 61000-6-2 and emission of interference per EN 61000-6-4
  8. Dimensions and Weight: 60 mm width, 30 mm height, 210 mm depth, 670 g
  9. Diagnostics and Device Functions: undervoltage, overcurrent, overload and overtemperature diagnostics, input filter 0.2 to 20 ms, Bluetooth and Android/iOS visualization app
  10. Conformity: CE marking, RoHS compliant without exemption
765-4201/100-000

Product Information

Technical Specifications

Specifications for 765-4201/100-000

ParameterValue
Width60 mm / 2.362 inches
Height30 mm / 1.181 inches
Depth210 mm / 8.268 inches
Weight670g
Conformity markingCE
Ambient temperature (operation)-25 … +70 °C
Ambient temperature (storage)-40 … +80 °C
Protection typeIP67
Protection classIII per EN 61140, IEC 61140, VDE 0140-1
Operating altitude0 2000 m / 0 6562 ft
Pollution degree3 (EN 60664-1)
Overvoltage categoryII (EN 60664-1)
Relative humidity (without condensation)95%
Vibration resistance5g per IEC 60068-2-6
Shock resistanceShort-term: 50g/11 ms/half-sine per IEC 60068-2-27; Long-term: 30g/6 ms/half-sine per IEC 60068-2-29
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-4
ETIM 9.0EC001601
ETIM 8.0EC001601
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
GTIN4066966063134
Customs tariff number8537109170
RoHS Compliance StatusCompliant,No Exemption
CommunicationsEtherCAT®
ParameterValue
Connection technology: communication/fieldbus2 x D-coded M12; 4-pole
Interface standard10BASE-T/100BASE-TX; potential-free
Autonegotiation; autocrossoveryes
ParameterInput filter
DiagnosticsUndervoltage; Overcurrent; Overload; Overtemperature
Device functionsBluetooth®
VisualizationAndroid/iOS app
IO-Link master classificationClass A; V1.1 specification
Port-ModusIO-Link: autoconfig, manual, tool-based
Cycle time400 渭s (min.)
Operating modeIO-Link master, DI or DO (adjustable for pin 4 per port); DI or DO (adjustable for pin 2 per port)
Number of digital inputs16
Number of digital outputs16
Connection technology: inputs / outputs8 x A-coded M12; 5-pole
Signal type (voltage)24 VDC
Input characteristicType 3, per IEC 61131-2
Input filter0.2 20 ms
Output current (per channel)2 A (typ.) for DO
Supply current per port1L: 1 A for IO-Link; 4 A (max.) for DIO
Connection technology: supply2 x L-coded M12; 5-pole
Supply voltage24 VDC (18 … 31.2 V); 1L
Current consumption (max.)16000mA
Current consumption (note)per supply line; overload- and short-circuit-protected
Reverse voltage protectionYes

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
WAGO 765-4201/100-000 - 8-Port IO-Link Master Class A, EtherCAT