- 869-389
WAGO 869-389 end plate for DIN rail terminal blocks, green-yellow, with M3 fixing flange. Dimensions: width 2.5 mm (0.098 inches), height 27.6 mm (1.087 inches), depth 33.4 mm (1.315 inches). Main housing insulation material is polyamide (PA66), material group I, flammability class V0 per UL94, fire load 0.053 MJ, weight 1.8 g. Product Group 16 (Rail Mounted Terminal Blocks with CCC). Classification: eCl@ss 10.0 and 9.0 27-14-11-33, ETIM 9.0 and 8.0 EC000886. Packaging: box, PU (SPU) 100 (25) pcs. RoHS status: compliant, no exemption. Country of origin DE; customs tariff number 8538906000.
- 869-395
WAGO 869-395 is a gray end plate for rail-mounted terminal blocks, with an M4 fixing flange and 2.5 mm thickness. Dimensions are 2.5 mm width, 27.6 mm height, and 33.4 mm depth. The main housing insulation material is polyamide (PA66), material group I, with a flammability class of V0 per UL94. Fire load is 0.052 MJ and weight is 1.7 g. It belongs to product group 16 (rail mounted terminal blocks with CCC). Classification codes are eCl@ss 10.0 and 9.0: 27-14-11-33; ETIM 9.0 and 8.0: EC000886. RoHS status is compliant, no exemption. Packaging is a box, PU (SPU) 100 (25) pcs.
- 869-398
WAGO 869-398 end plate with M4 fixing flange, blue, for rail chassis terminal blocks. Dimensions: 2.5 mm width, 27.6 mm height, 33.4 mm depth. Main housing insulation material is polyamide (PA66), material group I, flammability class V0 per UL94, fire load 0.047 MJ, weight 1.6 g. Product Group 16 (Rail Mounted Terminal Blocks with CCC). Classification: eCl@ss 10.0 and 9.0 27-14-11-33; ETIM 9.0 and 8.0 EC000886. RoHS compliance status: Compliant, No Exemption. Packaging type: box; PU (SPU) 100 (25) pcs. Country of origin: DE.
- 869-399
WAGO 869-399 end plate for rail chassis terminal blocks, green-yellow, with an M4 fixing flange. Dimensions are 2.5 mm width, 27.6 mm height, and 33.4 mm depth. The main housing insulation material is Polyamide (PA66), material group I, with a flammability class of V0 per UL94 and a fire load of 0.047 MJ. Weight is 1.6 g. The product group is 16 (Rail Mounted Terminal Blocks with CCC). Classification codes are eCl@ss 10.0 and 9.0: 27-14-11-33, and ETIM 9.0 and 8.0: EC000886. RoHS status is compliant, no exemption. Packaging is a box, with PU (SPU) 100 (25) pcs.
- 870-102
WAGO 870-102 is a gray, horizontal double-deck rail chassis terminal block for DIN-35 rail mounting. It has two levels, two clamping units, and two potentials, with N/L side marking. Connection uses CAGE CLAMP® technology with front-entry wiring and an operating tool. Solid conductors accept 0.08 to 2.5 mm² (28 to 12 AWG); fine-stranded conductors accept the same range. Maximum insulation diameter is 4.4 mm, strip length is 6 to 7 mm, and 2-conductor female plugs cannot be used. Rated voltage is 500 V and rated current 16 A at overvoltage category III / pollution degree 3. Dimensions are 5 mm wide, 70 mm high, and 40 mm deep from the DIN-rail upper edge. Housing material is polyamide PA66, flammability class V0 per UL94.
- 870-103
WAGO 870-103 rail chassis terminal block, gray, horizontal design for DIN-35 rail mounting. Two clamping units, two potentials, two levels, with L/N potential marking and side marking level. CAGE CLAMP connection with operating tool actuation; front-entry wiring for copper conductors. Solid conductor range 0.08 to 2.5 mm2 (28 to 12 AWG); fine-stranded 0.08 to 4 mm2 (28 to 12 AWG); fine-stranded with insulated ferrule 0.08 to 1.5 mm2 (28 to 14 AWG). Strip length 6 to 7 mm (0.24 to 0.28 inches). Maximum insulation diameter 4.4 mm; 2-conductor female plugs cannot be used. Rated voltage (III/3) 500 V, rated impulse voltage (III/3) 6 kV, rated current 16 A. Dimensions: 5 mm width, 70 mm height, 40 mm depth from upper DIN-rail edge. Polyamide PA66 housing, UL94 V0, 9.3 g.
- 870-104
WAGO 870-104 is a blue double-deck rail chassis terminal block with two levels, two clamping units, and two potentials, marked N/N. It mounts on DIN-35 rail in a horizontal design and uses CAGE CLAMP® connection with operating-tool actuation and front-entry wiring. Solid and fine-stranded copper conductors from 0.08 to 2.5 mm² (28–12 AWG) are accepted; strip length is 6–7 mm (0.24–0.28 inches). Maximum insulation diameter is 4.4 mm, and 2-conductor female plugs cannot be used. Rated voltage is 500 V (III/3), rated impulse voltage 6 kV (III/3), and rated current 16 A. Dimensions are 5 mm wide, 70 mm high, and 40 mm deep from the upper DIN-rail edge. Housing material is polyamide PA66, UL94 V0.
- 870-107
WAGO 870-107 rail chassis terminal block, green-yellow, horizontal design for DIN-35 rail mounting. It has two levels, two clamping units, one potential, and PE potential marking with side marking. Connection uses CAGE CLAMP® technology actuated by an operating tool, with front-entry wiring and copper conductors. Solid conductor range is 0.08 … 2.5 mm² (28 … 12 AWG); fine-stranded 0.08 … 2.5 mm² (28 … 12 AWG); with insulated ferrule 0.08 … 1.5 mm² (28 … 14 AWG). Strip length is 6 … 7 mm. Dimensions: width 5 mm, height 70 mm, depth from upper DIN-rail edge 40 mm. Maximum insulation diameter is 4.4 mm. Two-conductor female plugs cannot be used. Housing is polyamide (PA66), UL94 V0, weight 11 g.