- 756-1306/060-020
WAGO 756-1306/060-020 is a shielded system bus cable in yellow, 2 m long, with an M12 socket to M12 plug connection, 5 poles, B-coded at both interfaces, and 90° cable connection direction to mating direction at each end. Electrical ratings are 60 V operating voltage, 4 A operating current, 1.5 kV rated surge voltage per IEC 61076-2-101, 10 mΩ contact resistance, and conductor resistance ≤ 145 Ω/km. The cable is type KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid at approximately 65% optical coverage. Housing is TPU/TPU, black (~ RAL 9005); contacts are CuZn with CuNi/Au plating. Protection type is IP67. Ambient operating temperature is -25 … +60 °C. Maximum mating cycles: 100; tightening torque: 1 Nm; weight: 115 g.
- 756-1306/060-025
WAGO 756-1306/060-025 is a shielded M12 socket to M12 plug cable assembly, 5-pole, B-coded at both connector interfaces, with a 2.5 m cable length and 90° cable connection direction to mating direction at each end. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. Contact resistance is 10 mΩ; conductor resistance is ≤ 145 Ω/km. The cable is type KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid at approximately 65% optical coverage. Housing is TPU/TPU, black (~ RAL 9005). Protection type IP67; ambient operating temperature -25 … +60 °C. Maximum mating cycles 100; tightening torque 1 Nm; weight 138 g.
- 756-1306/060-030
WAGO 756-1306/060-030 is a shielded system bus cable, 3 m long, with a 90° M12 socket to 90° M12 plug, both B-coded and 5-pole. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. The cable is type KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid at approximately 65% optical coverage. Conductors are bare copper (26/7 AWG) with Zell-PE insulation, 1.0 mm maximum core diameter. Contact resistance is 10 mΩ and conductor resistance is ≤ 145 Ω/km. Housing is black TPU/TPU; contacts are CuZn with CuNi/Au plating. Protection type is IP67, ambient operating temperature is -25 to +60 °C, and maximum mating cycles are 100.
- 756-1306/060-050
WAGO 756-1306/060-050 is a shielded M12 connection cable with an M12 socket to M12 plug, 5-pole, B-coded at both interfaces, and a 5 m cable length. Both cable connection directions are 90° to the mating direction. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. The cable is type KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid at approximately 65 % optical coverage. Housing is TPU/TPU, black (~ RAL 9005); contacts are CuZn with CuNi/Au plating. Protection type is IP67, ambient operating temperature -25 … +60 °C, maximum mating cycles 100, tightening torque 1 Nm, weight 221 g.
- 756-1306/060-070
WAGO angled system bus cable, 756-1306/060-070, with M12 socket to M12 plug connections, both B-coded and oriented 90° to the mating direction. It has 5 poles and a 7 m cable length. Electrical ratings are 60 V operating voltage, 4 A operating current, 1.5 kV rated surge voltage per IEC 61076-2-101, 10 mΩ contact resistance, and conductor resistance ≤ 145 Ω/km. The cable is a shielded type KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω with aluminum-laminated foil and tinned copper braid, approx. 65 % optical coverage. Housing is black TPU/TPU; contacts are CuZn with CuNi/Au plating. Ambient operating temperature is -25 to +60 °C, protection type IP67, max. 100 mating cycles, tightening torque 1 Nm, weight 385 g.
- 756-1306/060-100
WAGO 756-1306/060-100 system bus cable, 10 m, with 5-pole B-coded M12 socket and M12 plug. Both cable connections are angled 90° to the mating direction. Operating voltage 60 V, operating current 4 A, rated surge voltage 1.5 kV per IEC 61076-2-101, contact resistance 10 mΩ, conductor resistance ≤ 145 Ω/km. Shielded construction: aluminum-laminated foil and tinned copper braid, optical coverage approx. 65 %. Housing TPU/TPU, black; contacts CuZn with CuNi/Au plating. Protection type IP67, ambient operating temperature -25 … +60 °C, maximum 100 mating cycles, tightening torque 1 Nm, weight 412 g. Pollution degree 3/2 per IEC 60664-1. RoHS compliant, no exemption.
- 756-1306/060-200
WAGO system bus cable, model 756-1306/060-200, with an M12 socket to M12 plug connection, 5-pole, B-coded at both interfaces, and 90° cable connection direction at each end. Cable length is 20 m. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. Protection type is IP67, with an operating ambient temperature range of -25 to +60 °C. The cable uses a shielded type code KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, with aluminum-laminated foil and tinned copper braid shielding at approximately 65 % optical coverage. Maximum mating cycles are 100, tightening torque is 1 Nm, and weight is 940 g.
- 756-1306/060-500
WAGO 756-1306/060-500 is a shielded cable assembly with an M12 socket to M12 plug connection, 5-pole, B-coded at both interfaces, and 90° cable connection direction to mating direction. Cable length is 50 m. Operating voltage is 60 V and operating current is 4 A. Rated surge voltage is 1.5 kV per IEC 61076-2-101. Contact resistance is 10 mΩ; conductor resistance is ≤ 145 Ω/km. The cable type is KS-02YS(ST+C)11Y 4x2xAWG26/7-100 Ω, shielded, with aluminum-laminated foil and tinned copper braid at approximately 65 % optical coverage. Housing is TPU/TPU, black (~ RAL 9005). Protection type is IP67. Ambient operating temperature is -25 … +60 °C. Maximum mating cycles are 100; tightening torque is 1 Nm.