Industrial Automation Parts. Prompt replies from real people.

WAGO 750-325 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the WAGO 750-325?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-325 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-325
Material Number
—
Manufacturer
WAGO
Product ID
49121

Get a Free Quote

Request pricing and availability for 750-325.

More parts to source? Send your whole list in one enquiry

Key specifications

Communications
CC-Link
Supply voltage (system)
24 VDC (-25 +30 %); via pluggable connector (CAGE CLAMP®connection)
Supply voltage (field)
24 VDC (-25 +30 %); via power jumper contacts
Weight
148.5g
Ambient temperature (operation)
0 … +55 °C
Protection type
IP20
See all specifications

Product Highlights

  1. CC-Link Support: Operates in CC-Link V2.0 (default) or V1.1 mode with selectable advanced cycle settings of 1, 2, 4 (default), or 8 cycles
  2. Network Capacity: Supports up to 64 fieldbus nodes on the master and up to 64 modules per node without bus extension, with a maximum bus segment length of 1200 m
  3. Transmission: 156/10 MBd transmission rate over shielded Cu cable 2 / 3 x 0.5 mm2, station addresses 1 to 4 (default 4)
  4. Process Image: Digital inputs/outputs from 16 to 880 bits and analog inputs/outputs from 4 to 128 words depending on mode and cycle setting, plus 16 bits per system area
  5. Power Supply: 24 VDC (-25 to +30%) system and field supply via CAGE CLAMP and power jumper contacts, 200 mA at 5 V system supply, 1800 mA total system current, 600 mA typical input current at 24 V nominal load, 90% efficiency, 500 V system/field isolation, and 3 outgoing power jumper contacts rated 10 A
  6. Connection and Mounting: CC-Link and device configuration via 4-pole male connectors, field supply via 6 x CAGE CLAMP and system supply via 2 x CAGE CLAMP for 0.08 to 2.5 mm2 (28 to 14 AWG) conductors with 8 to 9 mm strip length, DIN-35 rail mounting, 61.5 x 100 x 71.9 mm dimensions, 64.7 mm depth from DIN-rail upper edge, 148.5 g weight, polycarbonate and polyamide 6.6 housing
  7. Environmental and Compliance: 0 to +55 °C operating and -25 to +85 °C storage temperature, IP20, pollution degree 2 per IEC 61131-2, 0 to 2000 m operating altitude, 95% relative humidity without condensation, vibration per IEC 60068-2-6, 15 g shock per IEC 60068-2-27, EMC immunity per EN 61000-6-2 and emission per EN 61000-6-4, CE marking, RoHS compliant with exemption 6(c)
750-325

Product Information

Technical Specifications

Specifications for 750-325

ParameterValue
CommunicationsCC-Link
Device-specificOperating mode: CC-Link V2.0 (default setting)/V1.1; Advanced cycle setting: 1, 2, 4 (default setting), 8 cycles
Number of fieldbus nodes on master (max.)64
Transmission rate156/10 MBd
Bus segment length (max.)1200 m
Transmission medium (communication/fieldbus)Shielded Cu cable 2 / 3 x 0.5 mm2
Station addresses1 4 / 4 (default setting)
Number of modules per node (max.)64
Number of modules without a bus extension (max.)64
Input process image (note)RX (digital inputs): V1.1: 16, 48, 80, 112 bits; V2.0: 16, 48, 80, 112 bits (1 cycle); V2.0: 16, 80, 144, 208 bits (2 cycles); V2.0: 48, 176, 304, 432 bits (4 cycles); V2.0: 112, 368, 624, 880 bits (8 cycles) and 16 bits per system area; RWr (analog inputs): V1.1: 4, 8, 12, 16 words (16 bits); V2.0: 4, 8, 12, 16 words (1 cycle); V2.0: 8, 16, 24, 32 words (2 cycles); V2.0: 16, 32, 48, 64 words (4 cycles); V2.0: 32, 64, 96, 128 words (8 cycles)
Output process image (note)RY (digital outputs): V1.1: 16, 48, 80, 112 bits; V2.0: 16, 48, 80, 112 bits (1 cycle); V2.0: 16, 80, 144, 208 bits (2 cycles); V2.0: 48, 176, 304, 432 bits (4 cycles); V2.0: 112, 368, 624, 880 bits (8 cycles) and 16 bits per system area; RWw (analog outputs): V1.1: 4, 8, 12, 16 words (16 bits); V2.0: 4, 8, 12, 16 words (1 cycle); V2.0: 8, 16, 24, 32 words (2 cycles); V2.0: 16, 32, 48, 64 words (4 cycles); V2.0: 32, 64, 96, 128 words (8 cycles)
Supply voltage (system)24 VDC (-25 +30 %); via pluggable connector (CAGE CLAMP®connection)
Current consumption (5 V system supply)200mA
Total current (system supply)1,800mA
Supply voltage (field)24 VDC (-25 +30 %); via power jumper contacts
Input current (typ.) at nominal load (24 V)600mA
Power supply efficiency (typ.) at nominal load (24 V)90%
Isolation500 V system/field
Number of outgoing power jumper contacts3
Current carrying capacity (power jumper contacts)10A
Connection technology: communication/fieldbusCC-Link: 1 x Male connector; 4-pole
Connection technology: field supply6 x CAGE CLAMP®
Connection technology: system supply2 x CAGE CLAMP®
Connection type 1System/field supply
Solid conductor0.08 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Connection technology: device configuration1 x Male connector; 4-pole
Width61.5 mm / 2.421 inches
Height100 mm / 3.937 inches
Depth71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail64.7 mm / 2.547 inches
Mounting typeDIN-35 rail
ParameterValue
Housing materialPolycarbonate; polyamide 6.6
Fire load2.586MJ
Weight148.5g
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 2000 m / 0 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95%
Vibration resistanceper IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-4
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity < 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%25ppm
eCl@ss 10.027-24-26-07
eCl@ss 9.027-24-26-07
ETIM 9.0EC001603
ETIM 8.0EC001603
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
Customs tariff number8517620090
CAS-No.1303-86-2
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)b72ae42b-6d26-42c7-bbff-c71c15bcf27c
SCIP notification number (Belgium)7e8d85b0-dec6-4d47-8a1d-b4a890d14264
SCIP notification number (Bulgaria)ca7cf964-5a30-4608-adbc-f4870b7b7cd0
SCIP notification number (Czech Republic)fc6bb315-da69-4841-931e-d5e541f98ead
SCIP notification number (Denmark)1081514b-8d27-433d-9b77-039036d02acd
SCIP notification number (Finland)df2d9e9e-9e3f-4e37-913b-de80b3b8b08c
SCIP notification number (France)9dc24a20-f78a-466b-9d7d-2a9753c511b3
SCIP notification number (Germany)cb8f348d-9c8c-443d-b168-c0c698e05ffb
SCIP notification number (Hungary)d8c1ecbf-42b6-48e2-8e71-7278dc922e60
SCIP notification number (Italy)0c93aa3b-d946-4f68-a69a-33dad2dfe3f0
SCIP notification number (Netherlands)f1122e45-401e-423b-90a3-41dc871b2757
SCIP notification number (Poland)f11c1f18-8098-4419-b3a1-0263f800e0b5
SCIP notification number (Romania)5da268e2-f35a-4cbc-88be-71d4cd060d5a
SCIP notification number (Sweden)74758c2a-a6f8-493d-93c1-9a89aabd2180

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.