Industrial Automation Parts. Prompt replies from real people.

WAGO 2001-1311/1000-410 Rail Chassis Terminal Blocks

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 2001-1311/1000-410?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 2001-1311/1000-410 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
2001-1311/1000-410
Material Number
—
Manufacturer
WAGO
Product ID
49093

Get a Free Quote

Request pricing and availability for 2001-1311/1000-410.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
5g
Continuous operating temperature
-60 … +105 °C
Rated voltage UL (Use Group B)
600V
Rated current UL (Use Group B)
15A
Rated voltage UL (Use Group C)
600V
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Connection Technology: Push-in CAGE CLAMP with operating tool actuation and front-entry wiring
  2. Conductor Range: Nominal cross-section 1.5 mm2, solid and fine-stranded 0.25 to 2.5 mm2 (22 to 14 AWG), push-in termination from 0.75 mm2 (18 AWG), strip length 9 to 11 mm
  3. Electrical Ratings: Nominal voltage 250 V, reverse voltage 1000 V, maximum continuous current 500 mA, UL 1059 rated 600 V and 15 A for Use Groups B and C
  4. Housing: Gray polyamide (PA66), UL94 V0 flammability class, fire load 0.125 MJ
  5. Operating Temperature: Processing -35 to +85 °C, continuous -60 to +105 °C
  6. Dimensions and Mounting: 4.2 mm wide, 59.2 mm high, 32.9 mm deep from upper DIN-rail edge, DIN-35 rail mounting, 5 g weight
  7. Configuration: 3 clamping units, 1 potential, 1 level, 1 jumper slot, center and side marking
  8. Railway Compliance: Tested to DIN EN 50155 and DIN EN 61373 for shock and vibration, including 5 Hz to 150 Hz at 5 g for 5 h per axis and 30 ms half-sine shocks
  9. Environmental Compliance: RoHS compliant with exemption 7(a), REACH candidate list substance 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol present
2001-1311/1000-410

Product Information

Technical Specifications

Specifications for 2001-1311/1000-410

ParameterValue
Clamping units3
Total number of potentials1
Number of levels1
Number of jumper slots1
Width4.2 mm / 0.165 inches
Height59.2 mm / 2.33 inches
Depth from upper-edge of DIN-rail32.9 mm / 1.295 inches
Mounting typeDIN-35 rail
Marking levelCenter/side marking
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.125MJ
Weight5g
Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C
Product Group22 (TOPJOB S)
eCl@ss 10.027-14-11-27
eCl@ss 9.027-14-11-27
ETIM 9.0EC000903
ETIM 8.0EC000903
ECCNNO US CLASSIFICATION
PU (SPU)100 pcs
Packaging typebox
Country of originCN
GTIN4045454537562
Customs tariff number8536904000
CAS-No.7439-92-1
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption7(a)
SCIP notification number (Austria)df213f70-244b-4bc7-a882-3a8f7f53fb22
SCIP notification number (Belgium)7c99a122-ab14-436f-b882-dc548841f014
SCIP notification number (Bulgaria)6fca59c7-a3dd-4f83-ae2c-43aeae1829aa
SCIP notification number (Czech Republic)1ed3e8a7-93dd-42fd-82b9-efec303fcfaa
SCIP notification number (Denmark)944bad80-6cd2-44f2-a3ba-d2c5dfba9ebb
SCIP notification number (Finland)ebf3fadf-af36-4a4f-a404-469e0965902e
SCIP notification number (France)ce99e58d-1497-4892-b578-b4e3924b0e39
SCIP notification number (Germany)8c9179bf-1c82-4435-b354-ca235b545d8f
SCIP notification number (Hungary)eb102369-f855-41f2-86b2-82513010070d
SCIP notification number (Italy)474d4997-09dd-4dd5-8933-5766d4fe844f
SCIP notification number (Netherlands)5104c5fa-1065-4d38-a4a5-23197616c837
SCIP notification number (Poland)5ea85053-af21-4998-bfc9-11f55146b489
ParameterValue
SCIP notification number (Romania)13777d39-bef8-443e-8ce2-4886868d9b8e
SCIP notification number (Sweden)689b3586-7a43-4e94-9002-058c5a71ab36
Approvals perUL 1059
Rated voltage UL (Use Group B)600V
Rated current UL (Use Group B)15A
Rated voltage UL (Use Group C)600V
Rated current UL (Use Group C)15A
Nominal voltage250V
Reverse voltage1,000V
Continuous current (max.)500 mA
Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section1.5 mm2
Solid conductor0.25 2.5 m㎡/ 22 14 AWG
Solid conductor; push-in termination0.75 2.5 m㎡/ 18 14 AWG
Fine-stranded conductor0.25 2.5 m㎡/ 22 14 AWG
Fine-stranded conductor; with insulated ferrule0.25 1.5 m㎡/ 22 16 AWG
Fine-stranded conductor; with ferrule; push-in termination0.75 1.5 m㎡/ 18 16 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length9 11 mm / 0.35 0.43 inches
Wiring directionFront-entry wiring
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
WAGO TOPJOB S Component Terminal Block 2001-1311/1000-410