Industrial Automation Parts. Prompt replies from real people.

WAGO 281-623 /281-541 2-Conductor Fuse Terminal Block

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 281-623?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 281-623 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
281-623
Material Number
—
Manufacturer
WAGO
Product ID
48909

Get a Free Quote

Request pricing and availability for 281-623.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
19.5g
Continuous operating temperature
-60 … +105 °C
Rated voltage (III / 3)
800V
Rated impulse voltage (III / 3)
8kV
Rated current
10A
Power loss Pl max. overload and short-circuit protection (individual arrangement)
2.5W
See all specifications

Product Highlights

  1. Fuse Holder: Pivoting fuse receptacle for cylindrical fuses, 1/4 x 1-1/4 in
  2. Fuse Monitoring: No operation status indicator
  3. Connection Technology: CAGE CLAMP connection with operating tool actuation, front-entry wiring, 9 to 10 mm strip length
  4. Conductor Compatibility: Solid and fine-stranded copper conductors from 0.08 to 4 mm² (28 to 12 AWG), aluminum conductors up to 4 mm² (12 AWG) only with Alu-Plus Contact Paste 249-130
  5. Mounting: DIN-35 rail mounting, angled design, 10 mm wide, 60 mm high and 60 mm deep from the upper DIN-rail edge
  6. Electrical Ratings: 800 V rated voltage, 8 kV rated impulse voltage, 10 A rated current per IEC/EN 60947-7-3, with electrical ratings determined by the fuse
  7. Thermal and Material Data: Polyamide (PA66) housing, UL94 V0 flammability class, continuous operating temperature -60 to +105 °C, processing temperature -35 to +85 °C
281-623

Product Information

Technical Specifications

Specifications for 281-623

ParameterValue
Clamping units2
Total number of potentials2
Number of levels1
Width10 mm / 0.394 inches
Height60 mm / 2.362 inches
Depth from upper-edge of DIN-rail60 mm / 2.362 inches
Designangled
Mounting typeDIN-35 rail
Marking levelCenter marking
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.376MJ
Weight19.5g
Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C
Product Group1 (Rail Mounted Terminal Blocks)
eCl@ss 10.027-14-11-16
eCl@ss 9.027-14-11-16
ETIM 9.0EC000899
ETIM 8.0EC000899
ECCNNO US CLASSIFICATION
PU (SPU)50 pcs
Packaging typebox
Country of originCN
GTIN4045454620684
Customs tariff number8536904000
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60947-7-3
Rated voltage (III / 3)800V
Rated impulse voltage (III / 3)8kV
Rated current10A
Operation status indicatorNone
Legend (ratings)(III3) ≙ Overvoltage category IIIPollution degree 3
ParameterValue
Ratings (note)Electrical ratings are given by the fuse.
Power loss (max.) Pl (max.) (note)When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN?60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
Power loss Pl max. overload and short-circuit protection (individual arrangement)2.5W
Power loss Pl max. overload and short-circuit protection (group arrangement)1.6W
Power loss Pl max. short-circuit protection (individual arrangement)4W
Power loss Pl max. short-circuit protection (group arrangement)2.5W
Fuse receptaclepivoting
Fuse typeCylindrical fuse; ?" x 1?"
Connection technologyCAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Connectable conductor materials (note)Terminating Aluminum ConductorsWAGO Spring-Clamp Terminal Blocks are suitable for solid aluminum conductors up to 4 mm2/12 AWG if WAGO 鈥淎lu-PlusContact Paste249-130is used for termination.鈥淎lu-PlusContact Paste Advantages:Automatically destroys the oxide film during clamping.Prevents fresh oxidation at the clamping point.Prevents electrolytic corrosion between aluminum and copper conductors (in the same terminal block).Provides long-term protection against corrosion.Using terminal blocks with CAGE CLAMP®Spring Pressure Connection Technology,aluminum conductors must first be cleaned with a bladeand then immediately inserted into the clamping units filled with 鈥淎lu-Pluscontact paste.It is also possible to apply WAGO 鈥淎lu-Plus鈥漚dditionallyon the whole surface of the aluminum conductor before termination.Please note that the nominal currents must be adapted to the reduced conductivity of the aluminum conductors::2.5 mm2 = 16 A4 mm2 = 22 A
Solid conductor0.08 4 m㎡/ 28 12 AWG
Fine-stranded conductor0.08 4 m㎡/ 28 12 AWG
Strip length9 10 mm / 0.35 0.39 inches
Wiring directionFront-entry wiring

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp