Industrial Automation Parts. Prompt replies from real people.

WAGO 231-337/108-000 THT Male Header

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 231-337/108-000?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 231-337/108-000 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
231-337/108-000
Material Number
—
Manufacturer
WAGO
Product ID
48882

Get a Free Quote

Request pricing and availability for 231-337/108-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Anti-rotation protection
Yes
Weight
3g
Rated voltage (III / 3)
320V
Rated impulse voltage (III / 3)
4kV
Rated current
12A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Pole Count: 7 poles
  2. Pin Spacing: 5.08 mm / 0.2 inches
  3. Mounting: Threaded flange
  4. PCB Mounting Orientation: 90° mating direction to the PCB
  5. Coding: Variable coding with coding fingers
  6. Anti-Rotation Protection: Yes
  7. Contact Type: Male connector/plug
  8. Connection Type: For PCB
  9. Solder Pin Length: 5 mm
  10. Solder Pin Dimensions: 1 x 1 mm
  11. Drilled Hole Diameter: 1.4 (+0.1) mm
  12. Safety: Connectors without breaking capacity per DIN EN 61984, must not be connected or disconnected when live or under load, and header pins that can be touched must not be live when unmated
231-337/108-000

Product Information

Technical Specifications

Specifications for 231-337/108-000

ParameterValue
Safety informationTheMCS MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:Other pole numbers
Total number of potentials7
Number of connection types1
Number of levels1
Pin spacing5.08 mm / 0.2 inches
Width45.56 mm / 1.794 inches
Height17 mm / 0.669 inches
Height from the surface12 mm / 0.472 inches
Depth8.4 mm / 0.331 inches
Solder pin length5mm
Solder pin dimensions1 x 1 mm
Drilled hole diameter with tolerance1.4(+0.1)mm
Variable codingYes
Anti-rotation protectionYes
Contact type (pluggable connector)Male connector/plug
Connector (connection type)for PCB
Mismating protectionNo
Plugging without loss of pin spacingNo
Mating direction to the PCB90°
Locking of plug-in connectionThreaded flange
PCB contactTHT
Solder pin arrangementover the entire male connector (in-line)
Number of solder pins per potential1
Note (material data)Information on material specifications can be found here
Colororange
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Contact materialElectrolytic copper (ECu)
Contact platingTin
Fire load0.053MJ
Weight3g
Limit temperature range-60 … +100 °C
Processing temperature-35 … +60 °C
Product Group3 (Multi Conn. System)
eCl@ss 10.027-44-04-02
eCl@ss 9.027-44-04-02
ETIM 9.0EC002637
ETIM 8.0EC002637
ECCNNO US CLASSIFICATION
PU (SPU)100 pcs
Packaging typebox
Country of originPL
GTIN4050821868736
Customs tariff number8536694040
CAS-No.7439-92-1
REACH Candidate List SubstanceLead
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)8b40cdae-2b8b-4576-b070-29e2d37f5184
SCIP notification number (Belgium)0da5530b-3cfc-4560-a98a-6d31f811f850
SCIP notification number (Bulgaria)9550bd53-bb07-4719-b66a-ae9a52ba4c41
SCIP notification number (Czech Republic)9fc1b98b-f418-4aa5-a26e-ba9524ddb36f
SCIP notification number (Denmark)fca8439c-3d61-41ff-ba69-9784f630c524
ParameterValue
SCIP notification number (Finland)79f204ce-a2d2-4e2b-944c-05920556a1f2
SCIP notification number (France)69f6da53-725d-4f6a-a009-5f6ba559c4d8
SCIP notification number (Germany)d9167275-65f4-49f1-af9d-b7c10755c14c
SCIP notification number (Hungary)d07eb115-254e-498a-9128-98dcf737f4cb
SCIP notification number (Italy)ebf3fd08-11ea-46d1-a7d2-0815afc38eb3
SCIP notification number (Netherlands)1898cb63-858a-4422-91ee-ae4e4421c948
SCIP notification number (Poland)2c3a48c7-f3dc-45d5-9247-15281623dda5
SCIP notification number (Romania)f56b109d-ad8c-451d-b4c5-f4f56a09e709
SCIP notification number (Sweden)f5371083-c7cb-4aae-8553-e3b09c531e9e
Ratings perIEC/EN 60664-1
Rated voltage (III / 3)320V
Rated impulse voltage (III / 3)4kV
Rated voltage (III/2)320V
Rated surge voltage (III/2)4kV
Nominal voltage (II/2)630V
Rated surge voltage (II/2)4kV
Rated current12A
Legend (ratings)(III2) ≙ Overvoltage category IIIPollution degree 2
Approvals perCSA
Rated voltage UL (Use Group B)300V
Rated current UL (Use Group B)10A
Rated voltage UL (Use Group D)300V
Rated current UL (Use Group D)10A
Rated voltage (UL 1977)600V
Rated current UL 197710A
Rated voltage CSA (Use Group B)300V
Rated current CSA (Use Group B)10A
Rated voltage CSA (Use Group D)300V
Rated current CSA (Use Group D)10A
Number of poles7
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp