- vadm-200
The Festo VADM-200 vacuum generator has a 2 mm Laval nozzle nominal width and a 22 mm width dimension. It integrates an electrically operated shut-off valve and a compressed air filter with 40 µm filtration. Operating pressure is 29 psi to 116 psi, with a nominal operating pressure of 87 psi, maximum vacuum of 85%, and air supply time of 0.29 s at nominal operating pressure. The DC operating voltage range is 21.6 V to 26.4 V at 100% duty cycle. Pneumatic connection 1 is G1/4; the vacuum connection is G3/8; a pneumatic muffler is integrated at connection 3. Medium and ambient temperature range is 0°C to 60°C. Protection is IP65, weight 320 g, and c UL us Recognized (OL) certification is listed.
- vadm-200-n
Festo VADM-200-N vacuum generator, manufacturer ID 162521. It uses the Venturi principle with a 2 mm Laval nozzle and reaches a maximum vacuum of 85%. Operating pressure is 29 psi to 116 psi, nominal operating pressure 87 psi, with an air supply time of 0.29 s at nominal operating pressure. The integrated functions are shut-off valve, electric compressed air filter, and vacuum switch. The vacuum switch measures relative pressure piezoresistively over 0 psi to 14.5 psi, with a threshold setting range of -13.05 psi to 0 psi and hysteresis setting range of -7.25 psi to -0.725 psi. Electrical connection is a 4-pin M8x1 plug; DC operating voltage range is 21.6 V to 26.4 V. Pneumatic connection 1 is G1/4, vacuum connection G3/8, filtration grade 40 µm, width 22 mm, weight 330 g, protection IP65.
- vadm-200-p
Festo vacuum generator VADM-200-P, manufacturer ID 162520, with a 2 mm Laval nozzle and 22 mm width. Integrated functions include shut-off valve, electric compressed air filter, and vacuum switch. Operating pressure is 29 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%, and air supply time 0.29 s at nominal operating pressure. The piezoresistive vacuum switch measures relative pressure with a threshold setting range of -0.9 bar to 0 bar and hysteresis setting range of -0.5 bar to -0.05 bar, PNP output, N/O contact, LED display, and potentiometer adjustment. Electrical connection is a 4-pin M8x1 plug; DC operating voltage range is 21.6 V to 26.4 V. Pneumatic connection 1 is G1/4, vacuum connection G3/8, with integrated pneumatic muffler. Medium temperature 0°C to 60°C, ambient temperature 0°C to 50°C, IP65, weight 330 g.
- vadm-300
The Festo VADM-300 vacuum generator has a 3 mm Laval nozzle nominal width and a 22 mm width dimension. It integrates an electric shut-off valve and a compressed air filter with 40 µm filtration. Operating pressure is 29 psi to 116 psi, with nominal operating pressure 87 psi; maximum vacuum is 85%. Air supply time at nominal operating pressure is 0.26 s. The DC operating voltage range is 21.6 V to 26.4 V at 100% duty cycle. Pneumatic connection 1 is G1/4 and the vacuum connection is G3/8; a pneumatic muffler is integrated at connection 3. The unit weighs 340 g, has IP65 protection, and operates from 0°C to 60°C.
- vadm-300-n
The Festo VADM-300-N vacuum generator has a 3 mm Laval nozzle nominal width, a 22 mm width dimension, and a closed muffler construction type. It integrates a shut off valve, electric compressed air filter, and vacuum switch. Operating pressure is 29 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%, and air supply time at nominal operating pressure 0.26 s. The DC operating voltage range is 21.6 V to 26.4 V at 100% duty cycle. Switching output is NPN; measured variable is relative pressure with piezoresistive measuring principle. Pneumatic connection 1 is G1/4, vacuum connection G3/8, and electrical connection is a 4-pin M8x1 plug. Degree of protection is IP65; product weight 350 g.
- vadm-300-p
The Festo vadm-300-p vacuum generator has a Laval nozzle nominal width of 3 mm and a 22 mm width dimension. It integrates a shut-off valve, electric compressed air filter, and vacuum switch. The ejector provides high vacuum, with maximum vacuum of 85% and nominal operating pressure of 87 psi. Operating pressure range is 29 psi to 116 psi, and air supply time at nominal operating pressure is 0.26 s. The vacuum switch uses a piezoresistive measuring principle for relative pressure, with PNP switching output and N/O contact. Electrical connection is a 4-pin M8x1 plug; DC operating voltage range is 21.6 V to 26.4 V. Pneumatic connection 1 is G1/4, vacuum connection is G3/8, filtration grade is 40 um, and protection degree is IP65.
- vadm-45
Festo vacuum generator VADM-45, manufacturer ID 162500, with a 0.45 mm Laval nozzle nominal width and 10 mm width dimension. It uses the Venturi principle with an integrated electric shut-off valve and compressed air filter, closed valve function, and a closed-type muffler. Operating pressure is 21.75 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%, and air supply time 5.9 s at nominal operating pressure. The DC operating voltage range is 21.6 V to 26.4 V at 100% duty cycle. Filtration grade is 40 um. Medium and ambient temperature range is 0 C to 60 C. Protection degree IP65, weight 60 g, M5 pneumatic and vacuum connections, RoHS-compliant.
- vadm-45-n
The Festo VADM-45-N vacuum generator has a Laval nozzle nominal width of 0.45 mm and a 10 mm width dimension. It integrates a shut-off valve, electric compressed air filter, and vacuum switch. The ejector provides high vacuum, with maximum vacuum of 85% and nominal operating pressure of 87 psi; air supply time at nominal operating pressure is 5.9 s. Operating pressure range is 21.75 psi to 116 psi. The vacuum switch uses piezoresistive relative-pressure measurement, NPN switching output, N/O contact, and threshold value comparator, with a threshold setting range of -0.9 bar to 0 bar. Electrical connection is a 4-pin M8x1 plug; DC operating voltage range is 21.6 V to 26.4 V. Protection class is IP65. Product weight is 65 g.