- vadm-95-p
The Festo VADM-95-P vacuum generator has a 0.95 mm Laval nozzle nominal width and an 18 mm width dimension. Operating pressure is 29 psi to 116 psi, with nominal operating pressure 87 psi, maximum vacuum 85%, and air supply time 1.18 s at nominal operating pressure. It uses a closed muffler and can be mounted in any position. Integrated functions include a shut off valve, electric compressed air filter, and vacuum switch; filtration grade is 40 μm. The piezoresistive sensor measures relative pressure with a threshold value comparator, N/O contact, PNP switching output, and non-detenting manual override. DC operating voltage range is 21.6 V to 26.4 V at 100% duty cycle. Pneumatic and vacuum connections are G1/8. Weight is 220 g.
- vadmi-140
Festo VADMI-140 vacuum generator, manufacturer ID 162509. Laval nozzle nominal width 1.4 mm, width dimension 22 mm, product weight 320 g. Operating pressure 29 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%. Air supply time at nominal operating pressure with ejector pulse 0.19 s. DC operating voltage range 21.6 V to 26.4 V, duty cycle 100%, degree of protection IP65. Integrated functions: ejector pulse valve, electric flow control shut-off valve, electric compressed air filter, and non-return valve. Filtration grade 40 um. Pneumatic connection 1 G1/8, vacuum connection G1/4, integrated pneumatic muffler. Operating medium: compressed air as per ISO 8573-1:2010 [7:4:4]; oil lubrication not possible. Medium and ambient temperature 0 C to 60 C. Certification: c UL us - Recognized (OL).
- vadmi-140-ls-n
The Festo VADMI-140-LS-N vacuum generator has a 1.4 mm Laval nozzle nominal width and a 22 mm width dimension. Operating pressure is 29 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%, and maximum overload pressure 5 bar. Air supply time at nominal operating pressure with ejector pulse is 0.19 s. Integrated functions include an ejector pulse valve, electric flow control shut-off valve, electric compressed air filter air-saving function, electrical non-return valve, and vacuum switch. The piezoresistive sensor measures relative pressure with an NPN switching output and threshold value comparator. DC operating voltage range is 21.6 V to 26.4 V at 100% duty cycle. Medium temperature is 0°C to 60°C, ambient temperature 0°C to 50°C, degree of protection IP65, and weight 330 g.
- vadmi-140-ls-p
Festo vacuum generator VADMI-140-LS-P, manufacturer ID 171059. Laval nozzle nominal width 1.4 mm, width dimension 22 mm, closed muffler, high vacuum ejector characteristic. Integrated functions include ejector pulse valve, electric flow control shut-off valve, electric compressed air filter with air saving function, electrical non-return valve, and vacuum switch. Operating pressure 29 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%, maximum overload pressure 5 bar. DC operating voltage range 21.6 V to 26.4 V, PNP switching output, 4-pin M8x1 plug, IP65. Filtration grade 40 um. Medium temperature 0°C to 60°C, ambient temperature 0°C to 50°C. Weight 330 g. Pneumatic connection G1/8, vacuum connection G1/4.
- vadmi-140-n
The Festo VADMI-140-N vacuum generator has a 1.4 mm Laval nozzle nominal width, a 22 mm width dimension, and a maximum vacuum of 85%. Operating pressure is 29 psi to 116 psi, with a nominal operating pressure of 87 psi and a maximum overload pressure of 5 bar. It integrates an ejector pulse valve, electric flow control shut-off valve, electric compressed air filter, non-return valve, and vacuum switch. The piezoresistive sensor measures relative pressure with an NPN switching output and N/O contact. DC operating voltage range is 21.6 V to 26.4 V at 100% duty cycle. Compressed air must conform to ISO 8573-1:2010 [7:4:4]; oil lubrication is not possible. Protection is IP65, medium temperature 0°C to 60°C, ambient temperature 0°C to 50°C, weight 330 g.
- vadmi-140-p
Festo VADMI-140-P vacuum generator, manufacturer ID 162530, with a 1.4 mm Laval nozzle and 22 mm width. Operating pressure is 29 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%, and maximum overload pressure 5 bar. It uses compressed air per ISO 8573-1:2010 [7:4:4]; oil lubrication is not possible. Integrated functions include an ejector pulse valve, electric flow control shut-off valve, compressed air filter, non-return valve, and vacuum switch. Filtration grade is 40 µm. The piezoresistive vacuum switch measures relative pressure with a threshold setting range of -0.9 bar to 0 bar, PNP switching output, and 4-pin M8x1 plug. DC operating voltage range is 21.6 V to 26.4 V. Protection rating IP65; weight 330 g.
- vadmi-200
Festo VADMI-200 vacuum ejector, manufacturer ID 162510. Laval nozzle nominal width 2 mm, width dimension 22 mm, closed muffler construction, any mounting position. Operating pressure 29 psi to 116 psi, nominal operating pressure 87 psi, maximum vacuum 85%. Air supply time at nominal operating pressure with ejector pulse is 0.15 s. DC operating voltage range 21.6 V to 26.4 V, 100% duty cycle. Integrated functions: ejector pulse valve, electric flow control shut-off valve, electric compressed air filter, non-return valve. Filtration grade 40 µm, non-detenting manual override. Pneumatic connection 1 G1/4, vacuum connection G3/8, integrated pneumatic muffler. Medium and ambient temperature 0°C to 60°C, IP65, weight 350 g. c UL us Recognized (OL). Compressed air per ISO 8573-1:2010 [7:4:4]; oil lubrication not possible.
- vadmi-200-ls-n
Festo vacuum generator VADMI-200-LS-N, manufacturer ID 171062. Laval nozzle nominal width 2 mm, width dimension 22 mm, closed muffler construction, any mounting position. Integrated functions include ejector pulse valve, electric flow control shut-off valve, electric compressed air filter with air-saving function, electrical non-return valve, and vacuum switch. Operating pressure 29 to 116 psi; nominal operating pressure 87 psi; maximum vacuum 85%; maximum overload pressure 5 bar. DC operating voltage range 21.6 to 26.4 V, 100% duty cycle, NPN switching output. Medium temperature 0 to 60 degrees C, ambient temperature 0 to 50 degrees C, IP65, weight 360 g. Pneumatic connection G1/4, vacuum connection G3/8, 4-pin M8x1 plug. Compressed air per ISO 8573-1:2010 [7:4:4]; oil lubrication not possible.