- 756-5312/060-015
WAGO accessory cable 756-5312/060-015 is a 1.5 m, 5-pole sensor/actuator cable with an M12 A-coded plug and free end, angled 90° to the mating direction. Operating voltage is 250 VAC/DC, operating current 4 A, rated surge voltage 1.5 kV, contact resistance 10 mΩ, and conductor resistance ≤ 60 Ω/km. Protection type is IP67; pollution degree 3 per VDE 0110. Static operating temperature is -50 … +90 °C, dynamic -25 … +90 °C. The PUR sheath is halogen-free per DIN VDE 0472 Part 815 and flame resistant per IEC 332-2. Bending radius is 10 x cable diameter minimum, with 2Mio. bending cycles.
- 756-5312/090-015
WAGO 756-5312/090-015 is an 8-pole sensor/actuator cable, 1.5 m long, with an M12 plug to free end and 90° cable connection direction to mating direction. The connector interface is A-coded. Operating voltage is 250 VAC/DC, operating current 4 A, rated surge voltage 1.5 kV, contact resistance 10 mΩ, and conductor resistance ≤ 60 Ω/km. Protection type is IP67, with pollution degree 3 per VDE 0110. Static operating temperature range is -50 … +90 °C; dynamic range is -25 … +90 °C. The PUR sheath is halogen-free per DIN VDE 0472 Part 815 and flame resistant per IEC 332-2. Bending radius is 10 x cable diameter minimum, with 2Mio. bending cycles.
- 756-5312/090-050
WAGO 756-5312/090-050 is an 8-pole sensor/actuator cable with a 90° angled M12 A-coded plug and a free end, 5 m long. Operating voltage is 250 VAC/DC, operating current 4 A, rated surge voltage 1.5 kV, contact resistance 10 mΩ, and conductor resistance ≤ 60 Ω/km. Protection type is IP67; pollution degree 3 per VDE 0110. Static operating temperature range is -50 … +90 °C, dynamic -25 … +90 °C. Minimum bending radius is 10 x cable diameter, with 2Mio. bending cycles. The PUR sheath is halogen-free per DIN VDE 0472 Part 815 and flame resistant per IEC 332-2. RoHS status is compliant with exemption 6(c).
- 756-5401/030-020
WAGO 756-5401/030-020 is a 3-pole sensor/actuator cable with an M12 socket to M12 plug connection, both A-coded, and a 2 m cable length. It is rated for 250 VAC/DC and 4 A, with a rated surge voltage of 2.5 kV, contact resistance of 10 mΩ, and conductor resistance of ≤ 60 Ω/km. Protection type is IP67, and operating temperature ranges are -50 … +90 °C static and -25 … +90 °C dynamic. The cable uses fine-stranded bare copper conductors (42 x 0.1 mm), halogen-free PP9Y insulation, and a black halogen-free PUR sheath. Tightening torque is 1 Nm.
- 756-5402/030-010
WAGO sensor/actuator cable 756-5402/030-010, 1 m long, with a straight M12A socket and a 90° angled M12A plug. Both interfaces are 3-pole, A-coded, with a rated operating voltage of 250 VAC/DC and operating current of 4 A. Rated surge voltage is 2.5 kV; contact resistance is 10 mΩ and conductor resistance is ≤ 60 Ω/km. The cable uses fine-stranded bare copper conductors (42 x 0.1 mm), halogen-free PP9Y insulation, and a black halogen-free PUR sheath. Protection type is IP67, with an operating temperature range of -50 to +90 °C static and -25 to +90 °C dynamic. Minimum bending radius is 10 x cable diameter, with 2 million bending cycles. Tightening torque is 1 Nm.
- 756-5403/030-010
WAGO 756-5403/030-010 is a 3-pole M12 socket to M12 plug cable assembly with a 1 m cable length. The cable connection direction to the mating direction is 90° at one end and 0° at the other, with A-coding at both connector interfaces. Electrical ratings are 250 VAC/DC operating voltage, 4 A operating current, and 2.5 kV rated surge voltage. Contact resistance is 10 mΩ and insulation resistance is greater than 109 Ω. The cable uses fine-stranded bare copper conductors (42 x 0.1 mm), PP9Y halogen-free conductor insulation, and a black polyurethane sheath that is halogen-free per DIN VDE 0472 Part 815 and flame resistant per IEC 332-2. Protection type is IP67. Operating temperature is -50 to +90 °C static and -25 to +90 °C dynamic.
- 756-5404/030-010
WAGO sensor/actuator cable, model 756-5404/030-010, with M12 socket to M12 plug connectors, 3-pole, A-coded, both angled at 90°. Cable length 1 m, black PUR sheath, halogen-free per DIN VDE 0472 Part 815, flame resistant per IEC 332-2 and self-extinguishing. Conductors are fine-stranded bare copper, 42 x 0.1 mm, with halogen-free PP9Y insulation. Operating voltage 250 VAC/DC, operating current 4 A, rated surge voltage 2.5 kV, contact resistance 10 mOhm, conductor resistance at most 60 Ohm/km. Protection type IP67; pollution degree 3 per VDE 0110. Ambient operating temperature is -50 to +90 °C static and -25 to +90 °C dynamic. Tightening torque 1 Nm.
- 756-5404/030-020
WAGO sensor/actuator cable, model 756-5404/030-020, with an M12 socket to M12 plug connection, both A-coded and 3-pole, angled 90° at both ends. Cable length is 2 m. Operating voltage is 250 VAC/DC, operating current 4 A, rated surge voltage 2.5 kV, contact resistance 10 mΩ, and conductor resistance ≤ 60 Ω/km. Protection type is IP67. Static operating temperature range is -50 to +90 °C; dynamic range is -25 to +90 °C. The cable is rated for 2 Mio. bending cycles. Conductors are fine-stranded bare copper (42 x 0.1 mm) with halogen-free PP9Y insulation and a black halogen-free PUR sheath, flame resistant per IEC 332-2. Contacts are CuSn; tightening torque is 1 Nm.