Industrial Automation Parts. Prompt replies from real people.

WAGO 2006-1604 2-Conductor Through Terminal Block

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 2006-1604?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 2006-1604 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
2006-1604
Material Number
—
Manufacturer
WAGO
Product ID
48087

Get a Free Quote

Request pricing and availability for 2006-1604.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
19.6g
Rated voltage (III / 3)
800V
Rated impulse voltage (III / 3)
8kV
Rated current
30A
Rated current IN for specified power loss
30A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Connection Technology: Push-in CAGE CLAMP with operating tool actuation and front-entry wiring
  2. Conductor Range: Solid and fine-stranded 0.5 to 10 mm² (20 to 8 AWG), push-in termination from 2.5 mm² (14 AWG), insulated ferrules 0.5 to 6 mm² (20 to 10 AWG), strip length 13 to 15 mm
  3. Ratings: 800 V rated voltage and 8 kV rated impulse voltage per IEC/EN 60947-7-1, 30 A rated current, 600 V and 30 A per UL and CSA Use Groups B and C
  4. Mounting and Marking: DIN-35 rail mounting with center and side marking
  5. Housing: Blue polyamide PA66, UL94 V0 flammability class, continuous operating temperature -60 to +105 °C
  6. Railway Compliance: Tested to DIN EN 50155, DIN EN 61373 for shock and vibration, including 5 Hz to 150 Hz at 5g for 5 h per axis and 30 ms half-sine shocks
2006-1604

Product Information

Technical Specifications

Specifications for 2006-1604

ParameterValue
Clamping units2
Total number of potentials1
Number of levels1
Number of jumper slots2
Width7.5 mm / 0.295 inches
Height96.3 mm / 3.791 inches
Depth from upper-edge of DIN-rail32.9 mm / 1.295 inches
Depth38.9 mm / 1.531 inches
Mounting typeDIN-35 rail
Marking levelCenter/side marking
Note (material data)Information on material specifications can be found here
Colorblue
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.305MJ
Weight19.6g
Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C
Product Group22 (TOPJOB S)
eCl@ss 10.027-14-11-20
eCl@ss 9.027-14-11-20
ETIM 9.0EC000897
ETIM 8.0EC000897
ECCNNO US CLASSIFICATION
PU (SPU)25 pcs
Packaging typebox
Country of originCN
GTIN4050821181644
Customs tariff number8536904000
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60947-7-1
Rated voltage (III / 3)800V
Rated impulse voltage (III / 3)8kV
Rated current30A
Legend (ratings)(III3) ≙ Overvoltage category IIIPollution degree 3
Approvals perCSA 22.2 No 158
Rated voltage UL (Use Group B)600V
Rated current UL (Use Group B)30A
Rated voltage UL (Use Group C)600V
Rated current UL (Use Group C)30A
Rated voltage CSA (Use Group B)600V
Rated current CSA (Use Group B)30A
ParameterValue
Rated voltage CSA (Use Group C)600V
Rated current CSA (Use Group C)30A
Power loss, per pole (potential)0.702W
Rated current IN for specified power loss30A
Resistance value for specified, current-dependent power loss0.001Ω
Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section6 mm2
Solid conductor0.5 10 m㎡/ 20 8 AWG
Solid conductor; push-in termination2.5 10 m㎡/ 14 8 AWG
Fine-stranded conductor0.5 10 m㎡/ 20 8 AWG
Fine-stranded conductor; with insulated ferrule0.5 6 m㎡/ 20 10 AWG
Fine-stranded conductor; with ferrule; push-in termination2.5 6 m㎡/ 16 10 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length13 15 mm / 0.51 0.59 inches
Wiring directionFront-entry wiring
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.