Product Model
231-237/001-000
Material Number
—
Manufacturer
WAGO
Product ID
48053

Get a Free Quote

Request pricing and availability for 231-237/001-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Anti-rotation protection
Yes
Weight
2.8g
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated current
12A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Safety standard: Connectors without breaking capacity in accordance with DIN EN 61984, must not be connected or disconnected when live or under load, and header pins that can be touched must not be live when unmated
  2. Configuration: 7-pole male PCB connector with 7.5 mm pin spacing, 90° mating direction to the PCB, in-line THT solder pins arranged over the entire connector, one solder pin per potential, and no mismating protection
  3. Dimensions: 53.2 mm width, 17 mm height, 12 mm height from the surface, 8.4 mm depth, 5 mm solder pin length, 1 x 1 mm solder pin cross-section, and 1.4(+0.1) mm drilled hole diameter
  4. Electrical ratings: 12 A rated current, 500 V rated voltage (III/3), 630 V rated voltage (III/2), 1000 V nominal voltage (II/2), 6 kV rated impulse/surge voltage, and UL/CSA ratings of 300 V / 10 A (Use Groups B and D) and 600 V / 10 A (UL 1977)
  5. Materials and temperature range: gray PA66 insulation with UL94 V0 flammability class, tin-plated electrolytic copper contacts, limit temperature range -60 to +100 °C, and processing temperature range -35 to +60 °C
  6. Mechanical and environmental testing: passed DIN EN 50155, DIN EN 61373 shock and vibration tests for railway rolling stock equipment, including 5 Hz to 150 Hz at 5g for 5 h per axis, 30 ms half-sine shocks, and contact-fault and voltage-drop monitoring
  7. Additional features: variable coding, anti-rotation protection, RoHS compliant, 2.8 g weight, and 0.123 MJ fire load
231-237/001-000

Product Information

Technical Specifications

Specifications for 231-237/001-000

ParameterValue
Safety informationTheMCS MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:Other pole numbers
Total number of potentials7
Number of connection types1
Number of levels1
Pin spacing7.5 mm / 0.295 inches
Width53.2 mm / 2.094 inches
Height17 mm / 0.669 inches
Height from the surface12 mm / 0.472 inches
Depth8.4 mm / 0.331 inches
Solder pin length5mm
Solder pin dimensions1 x 1 mm
Drilled hole diameter with tolerance1.4(+0.1)mm
Variable codingYes
Anti-rotation protectionYes
Contact type (pluggable connector)Male connector/plug
Connector (connection type)for PCB
Mismating protectionNo
Plugging without loss of pin spacingNo
Mating direction to the PCB90°
Locking of plug-in connectionnone
PCB contactTHT
Solder pin arrangementover the entire male connector (in-line)
Number of solder pins per potential1
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Contact materialElectrolytic copper (ECu)
Contact platingTin
Fire load0.123MJ
Weight2.8g
Limit temperature range-60 … +100 °C
Processing temperature-35 … +60 °C
Product Group3 (Multi Conn. System)
eCl@ss 10.027-44-04-02
eCl@ss 9.027-44-04-02
ETIM 9.0EC002637
ETIM 8.0EC002637
ECCNNO US CLASSIFICATION
PU (SPU)50 pcs
Packaging typebox
Country of originPL
GTIN4044918864756
ParameterValue
Customs tariff number8536694040
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60664-1
Rated voltage (III / 3)500V
Rated impulse voltage (III / 3)6kV
Rated voltage (III/2)630V
Rated surge voltage (III/2)6kV
Nominal voltage (II/2)1000V
Rated surge voltage (II/2)6kV
Rated current12A
Legend (ratings)(III2) ≙ Overvoltage category IIIPollution degree 2
Approvals perCSA
Rated voltage UL (Use Group B)300V
Rated current UL (Use Group B)10A
Rated voltage UL (Use Group D)300V
Rated current UL (Use Group D)10A
Rated voltage (UL 1977)600V
Rated current UL 197710A
Rated voltage CSA (Use Group B)300V
Rated current CSA (Use Group B)10A
Rated voltage CSA (Use Group D)300V
Rated current CSA (Use Group D)10A
Number of poles7
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.