- 2020-211/125-000
WAGO 2020-211/125-000 rail chassis terminal block, gray, X-COM-System product group 18. Female connector/socket for conductor connection, 11 poles, 11 potentials, 22 clamping units, front-entry wiring via Push-in CAGE CLAMP with operating tool actuation. Dimensions: 39.2 mm width, 48.9 mm height, 29.8 mm depth, 3.5 mm module width. Rated 500 V, 6 kV impulse, 13.5 A per IEC/EN 61984 (III/3). UL ratings: 300 V, 15 A in Use Groups B, C, and D. CSA 22.2 No 158 ratings: 300 V, 10 A in Use Groups B, C, and D. Housing polyamide PA66, UL94 V0, material group I. Per EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load. An appropriate end plate must be applied to the carrier terminal blocks after each female plug.
- 2020-212/000-039
WAGO 2020-212/000-039 is a 12-pole female connector for conductor connection, using Push-in CAGE CLAMP® technology with operating-tool actuation. It accepts copper conductors from 0.14 to 1.5 mm² (24–16 AWG) solid and fine-stranded, with a 9–11 mm strip length and front-entry wiring. Dimensions are 42.7 mm wide, 40.5 mm high, and 25 mm deep, with 3.5 mm module width. Ratings per IEC/EN 61984: 500 V, 6 kV impulse, 13.5 A at overvoltage category III/pollution degree 3. UL ratings are 300 V and 15 A for Use Groups B, C, and D; CSA ratings are 300 V and 10 A. Housing is PA66, UL94 V0, operating from -60 to +105 °C. Per EN 61984, do not mate or unmate under load.
- 2020-213/000-037
WAGO 2020-213/000-037 is a 13-pole female connector for conductor connection in the X-COM-System product group 18. It uses Push-in CAGE CLAMP® technology with an operating tool and accepts copper conductors from 0.14 to 1.5 mm² (24–16 AWG), with a strip length of 9–11 mm. Dimensions are 46.2 mm wide, 40.5 mm high, and 25 mm deep, with 3.5 mm module width and 26 clamping units. The housing is polyamide (PA66), flammability class V0 per UL94, color green-yellow/gray. Ratings per IEC/EN 61984: 500 V, 6 kV impulse, 13.5 A at overvoltage category III/pollution degree 3. Processing temperature is -35 to +85 °C; continuous operating temperature is -60 to +105 °C. Per EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load. An appropriate end plate must be applied to the carrier terminal blocks after each female plug.
- 2020-214/000-036
WAGO 2020-214/000-036 is a gray/green-yellow female connector for conductor connection, part of Product Group 18 (X-COM-System). It uses Push-in CAGE CLAMP connection technology with operating tool actuation and front-entry wiring, and provides 14 poles, 28 clamping units, and 14 potentials. Dimensions are 49.7 mm width, 40.5 mm height, 25 mm depth, with 3.5 mm module width. Rated voltage (III / 3) is 500V, rated impulse voltage (III / 3) is 6kV, and rated current is 13.5A per IEC/EN 61984. Housing is Polyamide (PA66), UL94 V0, with a processing temperature of -35 to +85 °C and continuous operating temperature of -60 to +105 °C. Per EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.
- 2020-214/000-037
WAGO 2020-214/000-037 is a 14-pole female connector for conductor connection, part of Product Group 18 (X-COM-System). It uses Push-in CAGE CLAMP connection technology with front-entry wiring and an operating tool actuation type. Nominal cross-section is 1 mm2; solid and fine-stranded conductors accept 0.14 to 1.5 mm2 (24 to 16 AWG), with push-in termination from 0.5 mm2 (20 AWG). Strip length is 9 to 11 mm. Dimensions are 49.7 mm wide, 40.5 mm high, and 25 mm deep, with 3.5 mm module width. Ratings per IEC/EN 61984: 500 V, 6 kV impulse, 13.5 A at overvoltage category III, pollution degree 3. Housing is Polyamide (PA66), UL94 V0, green-yellow/gray. Operating temperature is -60 to +105 degrees C. Per EN 61984, these pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.
- 2020-214/000-039
WAGO 2020-214/000-039 is a 14-pole female connector for conductor connection, using Push-in CAGE CLAMP connection technology with operating tool actuation. It has 28 clamping units, 14 potentials, 3.5 mm module width, and front-entry wiring. Dimensions are 49.7 mm wide, 40.5 mm high, and 25 mm deep; weight is 38.5 g. The housing is Polyamide (PA66), flammability class V0 per UL94, color green-yellow/blue/gray. Connectable conductor material is copper. Solid and fine-stranded conductors accept 0.14 to 1.5 mm² (24 to 16 AWG); push-in termination accepts 0.5 to 1.5 mm² (20 to 16 AWG). Strip length is 9 to 11 mm. Rated voltage is 500 V and rated current 13.5 A per IEC/EN 61984.
- 2020-214/125-000
WAGO 2020-214/125-000 is a 14-pole gray female connector for conductor connection, using Push-in CAGE CLAMP® technology with operating-tool actuation and front-entry wiring. It has 28 clamping units and 14 potentials, a 3.5 mm module width, and overall dimensions of 49.7 mm width, 48.9 mm height, and 29.8 mm depth. Connection accepts copper conductors from 0.14 to 1.5 mm² (24–16 AWG), with 9–11 mm strip length. Ratings per IEC/EN 61984 are 500 V, 6 kV impulse, and 13.5 A at overvoltage category III / pollution degree 3. UL ratings are 300 V and 15 A for Use Groups B, C, and D; CSA ratings are 300 V and 10 A for the same groups. Housing is PA66, UL94 V0, operating from -60 to +105 °C.
- 2020-214/135-000
WAGO 2020-214/135-000 is a gray 14-pole female connector for conductor connection, using Push-in CAGE CLAMP technology with operating-tool actuation. It accepts copper conductors from 0.14 to 1.5 mm² (24–16 AWG); push-in termination accepts 0.5 to 1.5 mm² (20–16 AWG). Strip length is 9 to 11 mm. Dimensions are 49.7 mm wide, 69 mm high, and 25 mm deep, with 3.5 mm module width. The housing is polyamide (PA66), UL94 V0, material group I. Continuous operating temperature is -60 to +105 °C; processing temperature is -35 to +85 °C. Ratings per IEC/EN 61984: 500 V, 6 kV impulse, 13.5 A at overvoltage category III/pollution degree 3. Per EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.