- 753-469
WAGO 753-469 is a 2-channel analog input module for thermocouple K sensors, with 2 x (2-wire) sensor connection. Resolution over the entire range is 0.1 °C; typical conversion time is ≤320 ms. Measurement error at 25 °C is < ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K), temperature coefficient < ±0.2 K/K, internal resistance 1000 kΩ. Temperature range is ?100 … +1370 °C, with cold junction compensation at each pair of terminal blocks. Supply voltage is 5 VDC via data contacts; current consumption is 65 mA. Isolation is 500 V system/field. Inputs/outputs use 8 x CAGE CLAMP® for 0.08 … 2.5 mm2 (28–14 AWG), strip length 9–10 mm. Dimensions: 12 mm wide, 100 mm high, 69.8 mm deep. Mounting is DIN-35 rail. Protection type IP20. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-472
WAGO 753-472 is a 2-channel analog input module for current signals in the 0–20 mADC range, with single-ended signal characteristics. It provides 15-bit resolution, a maximum input resistance of 220 Ω, and a typical conversion time of ≤80 ms. Input filter frequency is 50 Hz, with noise rejection of -100 dB at the sampling frequency and -40 dB above it. Maximum input voltage is 24 V; input voltage is non-linear and overload protected per U = 1.2 V + 160 Ω x I meas. Overvoltage protection is 30 V, reverse polarity protected. Measurement error deviation is ≤±0.1% of upper-range value at a 25°C reference temperature. Sensor connection supports 2 x (2-wire, 3-wire). Data width is 2 x 16-bit data with optional 2 x 8-bit control/status. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-477
WAGO 753-477 is a 2-channel analog input module for voltage signals. It accepts a 0–10 VAC/DC differential input via 2 x (2-wire) sensor connections. Resolution is 15 bits, with a data width of 2 x 16-bit data and 2 x 8-bit control/status (optional). Internal resistance is 120 kΩ, and typical conversion time is ≤200 ms. Measurement error at a reference temperature of 25°C has a maximum deviation of ≤±0.1% of the upper-range value. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-478
WAGO 753-478 analog input module with 2 single-ended voltage inputs for 0–10 VDC signals. It provides 16-bit resolution and 2 x 16-bit data plus optional 2 x 8-bit control/status. Sensor connection is 2 x (2-wire). Input filter frequency is 50 Hz; maximum input voltage is 24 V. Internal resistance is 130 kΩ, typical conversion time is ≤80 ms, and noise rejection is -100 dB at sampling frequency and -40 dB above it. Maximum measurement error deviation is ≤±0.1% of the upper-range value at a reference temperature of 25°C. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-479
WAGO 753-479 is a 2-channel analog input module in the Controllers Bus Couplers I/O category. It accepts a ±10 VDC differential input. The module operates within an ambient temperature range of 0 to +55 degrees C. Its weight is 42.1 g. The product carries a CE conformity marking. No additional electrical, mechanical, or performance parameters are supplied for this model, and no compatibility, application, certification, or accessory information is stated beyond the details above. The model designation 753-479 is provided as the display model; no manufacturer part number or order code is given in the supplied data.
- 753-480
WAGO 753-480 is a two-channel analog input module for controllers, bus couplers, and I/O systems. It accepts a current signal range of 0 … 20 mA. Each channel uses a differential input to reduce noise. The module provides high accuracy analog measurement for industrial control panels.
- 753-482
WAGO 753-482 is a 2-channel analog input module for 4–20 mADC HART current signals, with 2 x (2-wire) sensor connection and single-ended signal characteristics. Input voltage is 24 V maximum; input voltage drop is non-linear and overload protected, U = 0.9 V + 270 Ω x I meas (I meas < 28 mA). Resolution is 12 bits, typical conversion time is ≤10 ms, and maximum deviation at the upper-range value is ≤±0.1% at a 25°C reference temperature. Diagnostics cover wire break and measurement range overflow. Overvoltage protection is 30 V with reverse polarity protection. The input filter is parameterizable channel by channel. Data width is 2 x 2-byte data; 2 x 2-byte data + 2n x 4-byte data (n = number of dynamic variables); 2 x 2-byte data + 6-byte mailbox. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-483
WAGO 753-483 is a 2-channel analog input module in the Controllers Bus Couplers I/O category. It uses a differential input configuration and accepts an input range of 0 to 30 VDC. The module measures 64 mm in height and 12 mm in width. Supplied weight figures are 48 g or 42 g. No additional electrical, mechanical, or performance parameters, standards, certifications, or compatible accessories are provided in the supplied data. The legacy description's characterization of the module as ideal for industrial automation and its accuracy, reliability, noise-reduction, and versatility claims are not supported by the supplied structured parameters and are therefore omitted.