Industrial Automation Parts. Prompt replies from real people.

WAGO 787-1722 Power Supplies

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 787-1722?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 787-1722 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
787-1722
Material Number
—
Manufacturer
WAGO
Product ID
47403

Get a Free Quote

Request pricing and availability for 787-1722.

More parts to source? Send your whole list in one enquiry

Key specifications

Isolation voltage (sec.-PE)
DC 0.7 kV
Series operation
Yes, for 2 devices of the same type
Weight
550g
Nominal input voltage [V]
1 x AC 100 240 V
Nominal output current Io nom
5 A (24 VDC; 110 240 VAC);?4 A (24 VDC; 100 240 VAC)
Nominal output power
120W
See all specifications

Product Highlights

  1. Output: 24 VDC SELV, 5 A nominal at 110–240 VAC input, 120 W nominal output power
  2. Input: 1-phase AC 100–240 V nominal, 90–264 VAC range, 125–375 VDC range, 47–63 Hz or 0 Hz, passive PFC
  3. Protection and isolation: short-circuit-protected and open-circuit-proof, isolation voltage DC 0.7 kV secondary-to-PE, protection class I, IP20 per EN 60529, overvoltage category II, pollution degree 2, primary varistor transient suppression
  4. Operation: parallel operation and series operation for 2 devices of the same type, green LED DC OK status indicator
  5. Mounting and connection: DIN-35 rail mount, CAGE CLAMP connection with WAGO 236 Series connectors, 0.08–2.5 mm² / 28–12 AWG solid and fine-stranded conductors, 6–7 mm strip length
  6. Ambient conditions: -20 to +60 °C operating, -25 to +75 °C storage, 10–95 % relative humidity without condensation, derating -3 %/K above 45 °C, climatic category 3K3 per EN 60721
  7. Compliance and reliability: EN 61204-3, CE marking, RoHS compliant, MTBF > 300,000 h per IEC 61709
787-1722

Product Information

Technical Specifications

Specifications for 787-1722

ParameterValue
Isolation voltage (sec.-PE)DC 0.7 kV
Protection classI
Protection typeIP20; per EN 60529
Overvoltage categoryII
Pollution degree2
Transient suppression (primary)Varistor
Short-circuit-protectedYes
Open-circuit-proofYes
Parallel operationYes
Series operationYes, for 2 devices of the same type
MTBF> 300,000 h (per IEC 61709)
Connection type 1Input/Output
Connection technologyCAGE CLAMP®
WAGO connectorWAGO 236 Series
Solid conductor0.08 … 2.5 mm2 / 28 12 AWG
Fine-stranded conductor0.08 … 2.5 mm2 / 28 12 AWG
Strip length6 7 mm / 0.24 0.28 inches
Note (conductor cross-section)12 AWG: THHN, THWN
Width60 mm / 2.362 inches
Height130 mm / 5.112 inches
Depth from upper-edge of DIN-rail99 mm / 3.898 inches
Mounting typeDIN-35 rail
Fire load0.129MJ
Weight550g
Ambient temperature (operation)-20 … +60 °C
Ambient temperature (storage)-25 … +75 °C
Relative humidity10 95 % (no condensation permissible)
Derating-3 %/K (> 45 °C)
Climatic category3K3 (per EN 60721)
Conformity markingCE
Standards/specificationsEN 61204-3
eCl@ss 10.027-04-07-01
eCl@ss 9.027-04-07-01
ETIM 9.0EC002540
ETIM 8.0EC002540
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
ParameterValue
Packaging typebox
Country of originCN
GTIN4055143372442
Customs tariff number8504409530
RoHS Compliance StatusCompliant,No Exemption
SCIP notification number (Bulgaria)aa2613f5-6113-400e-be75-dc6756207f88
SCIP notification number (Czech Republic)7ede9750-7374-4598-8c28-b0e5d82e38fc
Phases1
Nominal input voltage [V]1 x AC 100 240 V
Input voltage range1 x AC 90 264 V; DC 125 375 V
Nominal mains frequency range47 63 Hz;0 Hz
Input current Ii≤ 1 A (230 VAC); ≤ 2 A (115 VAC)
Inrush current≤ 18 A
Power factor correction (PFC)Passive
Mains failure hold-up time≤ 10 ms (230 VAC)
Nominal output voltage [V]DC 24 V (SELV)
Output voltage rangeDC 24 V
Default settingDC 24 V
Nominal output current Io nom5 A (24 VDC; 110 240 VAC);?4 A (24 VDC; 100 240 VAC)
Nominal output power120W
Deviation≤ 1 %
Residual ripple≤ 200 mV (peak-to-peak)
Overload behaviorConstant power (in overload range: 1.05 1.4 x Io nom); Shutdown and automatic restart in the event of a short circuit
Signaling1 x LED DC OK (green)
Operation status indicatorGreen LED (Uo)
Power loss Pl≤ 19 W
Efficiency (typ.)88 % (230 VAC; 5 ADC)
Internal fuseF 2.5 A / 250 VAC
Backup fusing (required)An external DC fuse is required for the DC input voltage.
Backup fusing (recommended)Circuit breaker: B6, B10