Product Model
750-610/040-000
Material Number
—
Manufacturer
WAGO
Product ID
47324

Get a Free Quote

Request pricing and availability for 750-610/040-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Signal type (voltage)
24 VDC
Supply voltage (system)
5 VDC; Via data contacts
Number of outgoing power jumper contacts
2
Weight
46.8g
Ambient temperature (operation)
-40 … +70 °C
Protection type
IP20
See all specifications

Product Highlights

  1. Supply Voltage: 24 VDC (-25 +30 %) via power jumper contacts, with power supply via CAGE CLAMP connection and transmission via spring contact
  2. Fuse Holder: Integrated fuse holder for 5 x 20 fuses, T 6.3 A (fuse not included)
  3. Diagnostics: Supply voltage (field) detection on at > 15 VDC and off at < 5 VDC
  4. Data Width: 2 bits, 1 bit current monitoring and 1 bit fuse fault
  5. Indicators: LED (A) red for defective fuse error and LED (B) green for power supply status
  6. System Supply: 5 VDC via data contacts, current consumption 5 mA
  7. Power Jumper Contacts: 2 outgoing power jumper contacts with 6.3 A current carrying capacity
  8. Rated Surge Voltage: 1 kV
  9. Derating: Must be observed, with limits by ambient temperature range and a lower limit of -27.5 % including 15 % residual ripple
  10. Weight: 46.755 g
750-610/040-000

Product Information

Technical Specifications

Specifications for 750-610/040-000

ParameterValue
Signal typeVoltage
Signal type (voltage)24 VDC
DiagnosticsSupply voltage (field): Detection 鈥渙nat > 15 VDC; Detection 鈥渙ffat < 5 VDC
Fuse5 x 20; T 6.3 A (not included)
Data width2 bits (1 bit current monitoring, 1 bit fuse fault)
Supply voltage (system)5 VDC; Via data contacts
Current consumption (5 V system supply)5mA
Supply voltage (field)24 VDC (-25 +30 %); Via power jumper contacts (power supply via CAGE CLAMP®connection; transmission via spring contact); Derating must be observed!
Rated surge voltage1 kV
IndicatorsLED (A) red: defective fuse error; LED (B) green: power supply status
Number of outgoing power jumper contacts2
Current carrying capacity (power jumper contacts)6.3A
DeratingDerating (supply voltage):Ambient temperatures under laboratory conditions: (?25 +30°%);for ?40 +55掳°C: 24掳V (?25 +20°%);for +55 +70°°C: 24掳V (?25 +10°%);Lower limit in all temperature ranges: ?27.5°% (including 15°% residual ripple)
Connection technology: field supply6 x CAGE CLAMP®
Connection type 1Field supply
Solid conductor0.25 2.5 m㎡/ 24 14 AWG
Fine-stranded conductor0.25 2.5 m㎡/ 24 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Width12 mm / 0.472 inches
Height100 mm / 3.937 inches
Depth67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail60.6 mm / 2.386 inches
Mounting typeDIN-35 rail
Colordark gray
Housing materialPolycarbonate; polyamide 6.6
Fire load0.995MJ
Weight46.8g
Conformity markingCE
Ambient temperature (operation)-40 … +70 °C
Ambient temperature (storage)-40 … 85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitudeWithout temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Mounting positionHorizontal left, horizontal up, vertical top and vertical bottom
Relative humidity (without condensation)95%
Relative humidity (with condensation)Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
ParameterValue
Vibration resistancePer IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
Shock resistancePer IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
EMC immunity to interferenceper EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
EMC emission of interferencePer EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutantsPer IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity &#60; 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity &#60; 75%25ppm
eCl@ss 10.027-24-26-10
eCl@ss 9.027-24-26-10
ETIM 9.0EC001600
ETIM 8.0EC001600
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4055143673280
Customs tariff number8538901000
CAS-No.1303-86-2
REACH Candidate List Substance4-Methyl-1,2-cyclohexanedicarboxylic anhydride
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)5f0c7827-9056-4403-919f-420f429d751a
SCIP notification number (Belgium)2edf10d9-8c12-40bd-8011-fbe8ce49e361
SCIP notification number (Bulgaria)b82956fd-85bb-4cbd-a2cc-a9bc592990fb
SCIP notification number (Czech Republic)82e5795b-c668-4146-a53d-177d0259cf41
SCIP notification number (Denmark)1bd7535d-e265-4ac1-8c16-186931171d10
SCIP notification number (Finland)5962422f-3c57-4f7b-a3da-35baa82af7e2
SCIP notification number (France)c92d10ad-087d-467a-ae18-ca1c710aca9e
SCIP notification number (Germany)3de830d2-f834-46cd-a92d-07cedb6f6e1d
SCIP notification number (Hungary)611a453b-d55d-4750-aa79-35dfce68ebf1
SCIP notification number (Italy)8828d7af-0d50-4f3c-a4fa-39016dc28d64
SCIP notification number (Netherlands)b4dba505-328b-43e3-9de9-7a6a8b8b5bde
SCIP notification number (Poland)c5160df5-3cf1-4e08-9c03-053c8db0dc6a
SCIP notification number (Romania)d5034573-5033-4249-912c-3118e0e384f6
SCIP notification number (Sweden)26fa49de-0c39-463d-a1fd-2cba44a071c1

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.