Industrial Automation Parts. Prompt replies from real people.

WAGO 2006-931/1099-836 Fuse Plug

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 2006-931/1099-836?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 2006-931/1099-836 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
2006-931/1099-836
Material Number
—
Manufacturer
WAGO
Product ID
46955

Get a Free Quote

Request pricing and availability for 2006-931/1099-836.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
6.6g
Continuous operating temperature
-60 … +105 °C
Rated voltage (III / 3)
800V
Rated current
10A
Rated voltage UL (Use Group B)
230V
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Fuse Type: Cylindrical fuse, 1/4 x 1 1/4 in
  2. Blown Fuse Indication: With indicator lamp, 230 V operation status indicator
  3. Electrical Ratings: Rated voltage 800 V (III/3), rated current 10 A, UL and CSA rated 230 V / 600 V, 15 A
  4. Housing: Gray polyamide (PA66), flammability class V0 per UL94, material group I, width 10.4 mm
  5. Operating Temperature: Continuous -60 to +105 °C
  6. Railway Compliance: Tested to DIN EN 50155 and DIN EN 61373 for shock and vibration
2006-931/1099-836

Product Information

Technical Specifications

Specifications for 2006-931/1099-836

ParameterValue
Width10.4 mm / 0.409 inches
Marking levelCenter marking
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.11MJ
Weight6.6g
Continuous operating temperature-60 … +105 °C
Product Group22 (TOPJOB S)
eCl@ss 10.027-14-11-49
eCl@ss 9.027-14-11-49
ETIM 9.0EC002018
ETIM 8.0EC002018
ECCNNO US CLASSIFICATION
PU (SPU)25 pcs
Packaging typebox
Country of originDE
GTIN4045454821135
Customs tariff number8536694040
CAS-No.1303-86-2
REACH Candidate List SubstanceDiboron trioxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)967449db-a260-40c8-b6a4-2af59bde2f8d
SCIP notification number (Belgium)8fa39c78-124d-4ddb-9341-3b630719e6cf
SCIP notification number (Bulgaria)329a5c2e-9705-485c-a3dc-ac76295a098f
SCIP notification number (Czech Republic)b2b447f2-8a40-4360-bee6-7c9ea465c9d6
SCIP notification number (Denmark)2e2e9e45-0a01-465e-87e9-cfe60f8bf7aa
SCIP notification number (Finland)947cd9a6-5c7f-4f6c-9306-ad2e33022c22
SCIP notification number (France)038f9e0c-a7d8-4c66-835d-f43af94b2494
SCIP notification number (Germany)2b462196-e647-413f-9d90-17e260d268d1
SCIP notification number (Hungary)d0e7800f-81c2-4e80-91f2-da4d151f37cd
SCIP notification number (Italy)d97d5fbb-8ff8-4a07-bc81-f23d58d8a6ca
SCIP notification number (Netherlands)94c7981f-37bf-4ab4-aed2-decb82049dad
SCIP notification number (Poland)52dfffd6-162d-4a15-8446-0c9bdab3db0c
SCIP notification number (Romania)7d458df1-9211-4072-b42e-9b7ce29879b4
SCIP notification number (Sweden)37b03344-8c56-46ed-a0a3-a0694011a886
Rated voltage (III / 3)800V
Rated current10A
Operation status indicator230 V
ParameterValue
Blown fuse indicationwith indicator lamp
Ratings (note)Electrical ratings are given by the fuse and blown fuse indication.
Rated current (note)Leakage current in case of a blown fuse: LED 2 mA
Approvals perCSA 22.2 No 158
Rated voltage UL (Use Group B)230V
Rated current UL (Use Group B)15A
Rated voltage UL (Use Group C)230V
Rated current UL (Use Group C)15A
Rated voltage CSA (Use Group B)600V
Rated current CSA (Use Group B)15A
Rated voltage CSA (Use Group C)600V
Rated current CSA (Use Group C)15A
Power loss (max.) Pl (max.) (note)When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN?60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers.
Fuse typeCylindrical fuse; ?" x 1?"
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
WAGO 2006-931/1099-836 Fuse Plug with Pull-Tab