WAGO 870-831 DIN Rail Mount Terminal Block

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 870-831?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 870-831 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
870-831
Material Number
—
Manufacturer
WAGO
Product ID
46838

Get a Free Quote

Request pricing and availability for 870-831.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
7.3g
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated current
24A
Rated current IN for specified power loss
24A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Mounting and design: DIN-35 rail mounting, horizontal design, 5 mm wide, 55 mm high, 27.5 mm deep from the upper edge of the DIN rail
  2. Connection technology: CAGE CLAMP® with front-entry wiring and operating tool actuation, 4 clamping units on 1 level for 1 potential
  3. Conductor range: solid and fine-stranded 0.08 to 2.5 mm² (28 to 12 AWG), fine-stranded with insulated ferrule 0.08 to 1.5 mm² (28 to 14 AWG), strip length 6 to 7 mm, max insulation diameter 4.4 mm
  4. Ratings: 24 A, 500 V, 6 kV rated impulse voltage, overvoltage category III / pollution degree 3 per IEC/EN 60947-7-1, 0.766 W power loss per pole at 24 A
  5. Housing and thermal data: gray PA66 housing, UL94 V0 flammability class, 0.118 MJ fire load, processing temperature -35 to +85 °C, continuous operating temperature -60 to +105 °C
  6. Railway compliance: tested to DIN EN 50155 and DIN EN 61373 for shock and vibration, including 5 Hz to 150 Hz at 5 g for 5 h per axis, 30 ms half-sine shocks, and contact-fault and voltage-drop monitoring
870-831

Product Information

Technical Specifications

Specifications for 870-831

ParameterValue
Safety informationMax. insulation diameter: 4.4 mm
Clamping units4
Total number of potentials1
Number of levels1
Width5 mm / 0.197 inches
Height55 mm / 2.165 inches
Depth from upper-edge of DIN-rail27.5 mm / 1.083 inches
Designhorizontal type
Mounting typeDIN-35 rail
Marking levelSide marking
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.118MJ
Weight7.3g
Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C
Product Group16 (Rail Mounted Terminal Blocks with CCC)
eCl@ss 10.027-14-11-20
eCl@ss 9.027-14-11-20
ETIM 9.0EC000897
ETIM 8.0EC000897
ECCNNO US CLASSIFICATION
PU (SPU)100 pcs
Packaging typebox
Country of originDE
GTIN4045454094621
Customs tariff number8536904000
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60947-7-1
Rated voltage (III / 3)500V
Rated impulse voltage (III / 3)6kV
Rated current24A
Legend (ratings)(III3) ≙ Overvoltage category IIIPollution degree 3
ParameterValue
Power loss, per pole (potential)0.766W
Rated current IN for specified power loss24A
Resistance value for specified, current-dependent power loss0.001Ω
Connection technologyCAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Solid conductor0.08 … 2.5 mm2 / 28 12 AWG
Fine-stranded conductor0.08 4 m㎡/ 28 12 AWG
Fine-stranded conductor; with insulated ferrule0.08 1.5 m㎡/ 28 14 AWG
Strip length6 7 mm / 0.24 0.28 inches
Wiring directionFront-entry wiring
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp