- 756-3102/040-020
WAGO 756-3102/040-020 is a 2 m power cable with an M12 A-coded socket, 4 poles, and a 90° cable exit relative to the mating direction. The opposite end is free. Electrical ratings are 250 VAC/DC, 4 A, 2.5 kV rated surge voltage, contact resistance 10 mΩ, and insulation resistance >109 Ω. The cable uses a Lif9YH-11YH 4x0.75 mm2 construction with bare copper conductors (40 x 0.15 mm) and halogen-free PP9Y insulation. The TPU/TPU housing is black (~ RAL 9005). Protection type is IP67, tightening torque 1 Nm, weight 10 g. Operating temperature is -30 … +80 °C in both dynamic and static conditions. Bending radius is 10 x cable diameter (min.) for flexible application; bending cycles are 4Mio. and drag chain capability is yes. Pollution degree is 3/2 per IEC 60664-1. End of sale 2024-05-01, end of production 2024-05-15, end of delivery 2024-06-01, end of service and repair 2025-06-01.
- 756-3102/040-050
WAGO 756-3102/040-050 is a 5 m cable assembly with an M12 socket to free end, 4 poles, A-coded, with a 90° cable connection direction to mating direction. Operating voltage is 250 VAC/DC and operating current is 4 A, with rated surge voltage 2.5 kV, contact resistance 10 mΩ, insulation resistance >109 Ω, and conductor resistance ≤ 26 Ω/km. The conductor is bare copper (40 x 0.15 mm) with PP9Y halogen-free insulation; housing is TPU/TPU, black (~ RAL 9005). Tightening torque is 1 Nm. Ambient operating temperature is -30 … +80 °C dynamic and static. Protection type is IP67. Drag chain capability is yes, with 4Mio. bending cycles and minimum bending radius 10 x cable diameter for flexible application. Pollution degree is 3/2 per IEC 60664-1.
- 756-3102/040-200
WAGO 756-3102/040-200 is an M12 socket to free-end cable assembly, A-coded, 4-pole, with a 90° cable exit relative to the mating direction. The cable is 20 m long, type Lif9YH-11YH 4x0.75 mm2, using bare copper conductors (40 x 0.15 mm) with halogen-free PP9Y insulation and a black TPU/TPU housing. Operating voltage is 250 VAC/DC at 4 A, with 2.5 kV rated surge voltage, 10 mΩ contact resistance, insulation resistance >109 Ω, and conductor resistance ≤ 26 Ω/km. Protection type is IP67; ambient operating temperature is -30 to +80 °C, static and dynamic. Tightening torque is 1 Nm. Drag-chain capable, 4 million bending cycles, minimum bending radius 10 x cable diameter for flexible application. Pollution degree 3/2 per IEC 60664-1.
- 756-3103/040-020
WAGO 756-3103/040-020 is a 2 m power supply cable with an M12 plug to free end, 4-pole, A-coded, with a 0° cable connection direction to mating direction. Electrical ratings are 250 VAC/DC operating voltage, 4 A operating current, 2.5 kV rated surge voltage, 10 mΩ contact resistance, >109 Ω insulation resistance, and ≤ 26 Ω/km conductor resistance. The cable uses a Lif9YH-11YH 4x0.75 mm2 type code with bare copper conductors (40 x 0.15 mm) and halogen-free PP9Y insulation. Housing is TPU/TPU, black (~ RAL 9005). Protection type is IP67; tightening torque is 1 Nm. Operating temperature is -30 … +80 °C dynamic and static. Bending radius is 10 x cable diameter (min.) for flexible application, with 4Mio. bending cycles and drag chain capability. Pollution degree is 3/2 per IEC 60664-1.
- 756-3104/040-020
WAGO 756-3104/040-020 is a 2 m power cable with an M12 A-coded plug, 4 poles, and a 90° cable outlet to mating direction; the opposite end is free. Operating voltage is 250 VAC/DC at 4 A, with 2.5 kV rated surge voltage, 10 mΩ contact resistance, and conductor resistance ≤ 26 Ω/km. The cable uses a Lif9YH-11YH 4x0.75 mm2 construction with bare copper conductors (40 x 0.15 mm) and halogen-free PP9Y insulation. The TPU/TPU housing is black (~ RAL 9005), IP67, with 1 Nm tightening torque. Dynamic and static operating temperature is -30 … +80 °C. Minimum bending radius for flexible application is 10 x cable diameter; drag chain capability is stated at 4Mio. bending cycles.
- 756-3104/040-050
WAGO 756-3104/040-050 is a 5 m power cable with a 4-pole, A-coded M12 plug at one end and a free end. The cable connection is angled 90° to the mating direction. Operating voltage is 250 VAC/DC and operating current is 4 A, with a rated surge voltage of 2.5 kV. Contact resistance is 10 mΩ and conductor resistance is ≤ 26 Ω/km. The conductor configuration is bare copper wire (40 x 0.15 mm) with halogen-free PP9Y insulation, type code Lif9YH-11YH 4x0.75 mm2. The housing is black TPU/TPU (~ RAL 9005). Protection type is IP67, with a tightening torque of 1 Nm. Operating temperature is -30 to +80 °C, both dynamic and static. Bending radius is at least 10 x cable diameter for flexible application, with 4 million bending cycles and drag chain capability. Weight is 10 g.
- 756-3104/040-100
WAGO 756-3104/040-100 is a 10 m power supply cable with an M12 plug to free end, 4-pole, A-coded, with a 90° cable connection direction to mating direction. Electrical ratings are 250 VAC/DC, 4 A, 2.5 kV rated surge voltage, 10 mΩ contact resistance, and insulation resistance >109 Ω. The cable uses a Lif9YH-11YH 4x0.75 mm2 type code with bare copper conductors (40 x 0.15 mm) and halogen-free PP9Y insulation. The black TPU housing offers IP67 protection. Operating temperature is -30 … +80 °C in both dynamic and static conditions. Minimum bending radius is 10 x cable diameter for flexible application, with 4Mio. bending cycles and drag chain capability. Tightening torque is 1 Nm; weight 10 g. Pollution degree 3/2 per IEC 60664-1.
- 756-3104/040-200
WAGO 756-3104/040-200 is a 20 m power cable with an M12 A-coded plug, 4 poles, and a free end. The cable exits at 90° to the mating direction. Operating voltage is 250 VAC/DC and operating current is 4 A, with a rated surge voltage of 2.5 kV. Contact resistance is 10 mΩ and conductor resistance is ≤ 26 Ω/km. The conductor is bare copper (40 x 0.15 mm) with halogen-free PP9Y insulation; the housing is black TPU/TPU. Protection type is IP67, tightening torque is 1 Nm, and operating temperature is -30 … +80 °C both dynamic and static. Bending radius is at least 10 x cable diameter for flexible application, with 4Mio. bending cycles and drag chain capability.