Product Model
750-487/003-000
Material Number
—
Manufacturer
WAGO
Product ID
45285

Get a Free Quote

Request pricing and availability for 750-487/003-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Supply voltage (system)
5 VDC; via data contacts
Supply voltage (field)
24 VDC; (Ex i power supply: Uo= max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
Power consumption Pmax.
0.3 W (max.)
Weight
90.5g
Ambient temperature (operation)
0 … +55 °C
Protection type
IP20
See all specifications

Product Highlights

  1. Analog Inputs: 2 channels for thermocouple or voltage signals
  2. Thermocouple Types: Default type K, configurable for J, B, E, L, N, R, S, T, U and C
  3. Voltage Measurement: Three ranges of ±30 mV, ±60 mV and ±120 mV
  4. Temperature Range: Type-dependent from -100 to +1,800 °C
  5. Resolution and Conversion: 0.1 °C or 0.01 mV resolution with typical conversion time ≤ 320 ms for both channels
  6. Ex i Operation: Must only be operated via 24 VDC Ex i, intrinsically safe with ATEX and EN IEC 60079 certification
750-487/003-000

Product Information

Technical Specifications

Specifications for 750-487/003-000

ParameterValue
NoteThe analog input module must only be operated via 24 VDC Ex i!General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals!
Order text2-Channel Analog Input; TC
Number of analog inputs2
Number of Channels2
Signal typeThermocouple
Signal type (configurable)Yes
Sensor connection2 x (2-wire)
Sensor typesThermocouple K; Configurable: J, B, E, L, N, R, S, T, U, C; Voltage sensor: ±30 mV, ±60 mV, ±120 mV
Temperature rangeType-dependent from ?100 to +1,800 °C
Measurement rangeThermocouples:Type B: +600 +1.800 °C; Type E: 00 +1.000 °C; Type J: 00 +1.200 °C; Type K: 00 +1.370 °C* *(default setting); Type L: -100 … +900 °C; Type N: 00 +1.300 °C; Type R: 0 +1.700 °C; Type S: 0 +1.700 °C; Type T: 00 … +400 °C; Type U: -25 … +600 °C;Voltage sensors:MB1: ±30 mV; MB2: ±60 mV; MB3: ±120 mV
Resolution (over entire range)0.1 °C or 0.01 mV for voltage measurement
Conversion time (typ. ≤ 320ms
Conversion time≤ 320 ms (both channels)
Measurement error (25 °C)< ±6 K (voltage input < ±2 K; cold junction compensation < ±4 K)
Temperature coefficient< ± 0.2 K / K of the largest output area (type K)
Cold junction compensationinternal; at each pair of terminal blocks
Internal resistance1000kΩ
Intrinsically safe Ex iYes
Data width2 x 16-bit data; 2 x 8-bit control/status (optional)
Configuration optionsWAGO-I/O-CHECK
Supply voltage (system)5 VDC; via data contacts
Current consumption (5 V system supply)13.5mA
Supply voltage (field)24 VDC; (Ex i power supply: Uo= max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
Current consumption, field supply (module with no external load)8.5mA
Power consumption Pmax.0.3 W (max.)
Power loss Pl0.3 W (max.)
Isolation300 VAC system/supply
Number of incoming power jumper contacts2
Number of outgoing power jumper contacts2
IndicatorsLED (A, E) green: Function AI 1, AI 2; LED (B, F) red: Error AI 1, AI 2
IdentificationATEXII 3 (1) G Ex ec [ia Ga] IIC T4 GcII (1) D [Ex ia Da] IIICI (M1) [Ex ia Ma] I
Ex standardEN IEC 60079-0, -7, -11
Safety-relevant data (circuit)Uo= 14.4 V; Io= 29.1 mA; Po= 52.4 mW; linear characteristic curve
Reactances Ex ia IICLo= 52 mH; Co= 650 nF
Reactances Ex ia IIBLo= 100 mH; Co= 4.0 µF
Reactances Ex ia IIALo= 300 mH; Co= 15.8 µF
Reactances Ex ia ILo= 400 mH; Co= 17.9 µF
Reactances (note)Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)
Connection technology: inputs / outputs8 x CAGE CLAMP®
Connection type 1Inputs/outputs
Solid conductor0.08 2.5 mm2 / 28 14 AWG
Fine-stranded conductor0.08 2.5 mm2 / 28 14 AWG
Strip length8 9 mm / 0.31 0.35 inches
Width24 mm / 0.945 inches
Height100 mm / 3.937 inches
Depth67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail60.6 mm / 2.386 inches
Mounting typeDIN-35 rail
ParameterValue
Housing materialPolycarbonate; polyamide 6.6
Fire load2.063MJ
Weight90.5g
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 2000 m / 0 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95%
Vibration resistance4g per IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2, marine applications
EMC emission of interferenceper EN 61000-6-3, marine applications
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity &#60; 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity &#60; 75%25ppm
Product Group15 (I/O System)
eCl@ss 10.027-24-26-01
eCl@ss 9.027-24-26-01
ETIM 9.0EC001596
ETIM 8.0EC001596
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
Customs tariff number85389099990
End of Sale2021-12-31
End of Production2022-02-01
End of Delivery2022-03-01
End of Service and Repair2023-12-31
CAS-No.1303-86-2
REACH Candidate List SubstanceDiboron trioxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)b56dfa7d-18b4-474a-a83f-27930136fc21
SCIP notification number (Belgium)93594fcd-27f9-4e10-9170-da2494291795
SCIP notification number (Bulgaria)653f4453-099b-424a-bfa1-1c96483e7cec
SCIP notification number (Czech Republic)e7505689-c728-4ae4-9d13-7f86edb9e571
SCIP notification number (Denmark)423af5ab-9257-4495-9eea-7cadd8545cf9
SCIP notification number (Finland)82a236c9-ebe6-453d-9790-d157a3db26af
SCIP notification number (France)54ceb1ea-d176-4d7a-a669-f3f1fd9a4198
SCIP notification number (Germany)5042dc3f-9a4c-4853-afed-28f43231691e
SCIP notification number (Hungary)220162ce-bc1b-4bbc-b0b4-1820d09f3d76
SCIP notification number (Italy)00cc9733-cdf5-42e1-91c2-ab11868cb841
SCIP notification number (Netherlands)220cfcbb-131b-4ba4-b415-b089b4c46e4d
SCIP notification number (Poland)812ac902-7ae5-41bc-ac4e-912e853f052b
SCIP notification number (Romania)31380e67-cfa0-4185-add1-d14563061995
SCIP notification number (Sweden)1b2fe975-a8ea-4639-8739-68e1ee12d760

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.