Product Model
832-1202/306-000
Material Number
—
Manufacturer
WAGO
Product ID
45210

Get a Free Quote

Request pricing and availability for 832-1202/306-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Anti-rotation protection
Yes
Weight of insulation material
11.43g
Rated voltage (III / 3)
1000V
Rated impulse voltage (III / 3)
8kV
Rated current
76A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Connection technology: Push-in CAGE CLAMP with lever actuation, accepts solid and fine-stranded conductors from 0.75 to 25 mm² (18 to 4 AWG), strip length 18 to 20 mm
  2. Ratings: 76 A rated current and 1000 V rated voltage per IEC/EN 60664-1, 8 kV rated impulse voltage, UL 600 V / 66 A (Use Groups B and C) and UL 1977 85 A, CSA 600 V / 66 A
  3. Housing and contacts: Light gray PBT insulation, UL94 V0 flammability class, chrome-nickel spring steel clamping springs, silver-plated electrolytic copper contacts, limit temperature range -60 to +120 °C
  4. Mounting and configuration: DIN-35 rail mounting, 10.16 mm pin spacing, 2 poles, 2 clamping units, 2 potentials, variable coding, anti-rotation protection, mismating protection
  5. Railway compliance: Tested to DIN EN 50155 and DIN EN 61373 for rolling stock equipment, including shock and vibration tests at 5 g from 5 to 150 Hz with contact-fault monitoring and voltage drop measurement
832-1202/306-000

Product Information

Technical Specifications

Specifications for 832-1202/306-000

ParameterValue
Safety informationTheMCS MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:Other pole numbers
Clamping units2
Total number of potentials2
Number of connection types1
Number of levels1
Pin spacing10.16 mm / 0.4 inches
Width21.62 mm / 0.851 inches
Height29.1 mm / 1.146 inches
Depth92.9 mm / 3.657 inches
Variable codingYes
Mounting typeDIN-35 rail
Anti-rotation protectionYes
Contact type (pluggable connector)Male connector/plug
Connector (connection type)for conductor
Mismating protectionYes
Plugging without loss of pin spacingNo
Locking of plug-in connectionnone
Note (material data)Information on material specifications can be found here
Colorlight gray
Material groupI
Insulation material (main housing)Polybutylene terephthalate (PBT)
Flammability class per UL94V0
Clamping spring materialChrome-nickel spring steel (CrNi)
Contact materialElectrolytic copper (ECu)
Contact platingSilver
Fire load0.843MJ
Actuator colororange
Weight of insulation material11.43g
Weight35.6g
Limit temperature range-60 … +120 °C
Processing temperature-35 … +60 °C
ETIM 9.0EC001284
ETIM 8.0EC001284
ECCNNO US CLASSIFICATION
PU (SPU)10 pcs
Packaging typeBox
Country of originDE
GTIN4066966114119
Customs tariff number8536694040
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60664-1
Rated voltage (III / 3)1000V
Rated impulse voltage (III / 3)8kV
Rated voltage (III/2)1000V
Rated surge voltage (III/2)8kV
Nominal voltage (II/2)1000V
ParameterValue
Rated surge voltage (II/2)8kV
Rated current76A
Legend (ratings)(III2) ≙ Overvoltage category IIIPollution degree 2
Approvals perCSA
Rated voltage UL (Use Group B)600V
Rated current UL (Use Group B)66A
Rated voltage UL (Use Group C)600V
Rated current UL (Use Group C)66A
Rated voltage (UL 1977)600V
Rated current UL 197785A
Rated voltage CSA (Use Group B)600V
Rated current CSA (Use Group B)66A
Rated voltage CSA (Use Group C)600V
Rated current CSA (Use Group C)66A
Connection technologyPush-in CAGE CLAMP®
Actuation typeLever
Solid conductor0.75 16 m㎡/ 18 4 AWG
Fine-stranded conductor0.75 25 m㎡/ 18 4 AWG
Fine-stranded conductor; with insulated ferrule0.75 16 mm2
Fine-stranded conductor; with uninsulated ferrule0.75 16 mm2
Strip length18 20 mm / 0.71 0.79 inches
Number of poles2
Conductor entry direction to mating direction0°
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.