Industrial Automation Parts. Prompt replies from real people.

WAGO 765-1105/100-000 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the WAGO 765-1105/100-000?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 765-1105/100-000 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
765-1105/100-000
Material Number
—
Manufacturer
WAGO
Product ID
44792

Get a Free Quote

Request pricing and availability for 765-1105/100-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
390g
Ambient temperature (operation)
-25 … +70 °C
Protection type
IP67
Overvoltage category
II (EN 60664-1)
Output current (per channel)
2 A (typ.) for DO
Supply voltage
24 VDC (18 … 31.2 V); 1L/2L
See all specifications

Product Highlights

  1. Digital I/O: 8 digital inputs and 8 digital outputs, 24 VDC, Type 3 per IEC 61131-2, with 0.2–20 ms input filter
  2. Output Current: 2 A typical per digital output channel, overload- and short-circuit-protected
  3. Fieldbus: PROFINET IO device with 2-port switch, LLDP, MRP, SNMP, and 2 x D-coded M12 4-pole communication connections
  4. Supply: 24 VDC (18–31.2 V) via 2 x L-coded M12 5-pole connections, 4 A max per supply port, reverse voltage protection
  5. I/O Connections: 8 x M8 3-pole connections
  6. Environmental Rating: IP67, operating temperature -25 to +70 °C, storage -40 to +80 °C, 95% relative humidity without condensation
  7. Mechanical and EMC: 35 x 30 x 210 mm, 390 g, 5g vibration per IEC 60068-2-6, 50g/11 ms and 30g/6 ms shock per IEC 60068-2-27/-29, EMC per EN 61000-6-2 and EN 61000-6-4
  8. Compliance: CE, protection class III per EN 61140, pollution degree 3 and overvoltage category II per EN 60664-1, RoHS compliant with exemption 6(c)
765-1105/100-000

Product Information

Technical Specifications

Specifications for 765-1105/100-000

ParameterValue
Width35 mm / 1.378 inches
Height30 mm / 1.181 inches
Depth210 mm / 8.268 inches
Weight390g
Conformity markingCE
Ambient temperature (operation)-25 … +70 °C
Ambient temperature (storage)-40 … +80 °C
Protection typeIP67
Protection classIII per EN 61140, IEC 61140, VDE 0140-1
Operating altitude0 2000 m / 0 6562 ft
Pollution degree3 (EN 60664-1)
Overvoltage categoryII (EN 60664-1)
Relative humidity (without condensation)95%
Vibration resistance5g per IEC 60068-2-6
Shock resistanceShort-term: 50g/11 ms/half-sine per IEC 60068-2-27; Long-term: 30g/6 ms/half-sine per IEC 60068-2-29
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-4
ETIM 9.0EC001599
ETIM 8.0EC001599
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typebox
Country of originDE
GTIN4055143949705
Customs tariff number8537109170
CAS-No.7439-92-1
REACH Candidate List SubstanceLead
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)fc81964e-bcd2-4fb0-8c80-389abc734aa6
SCIP notification number (Belgium)292d81f3-f672-4e32-b971-8165fd63de3e
SCIP notification number (Bulgaria)d0229fe5-1a4c-4edf-8d62-3e861bb4359b
SCIP notification number (Czech Republic)56dca3ae-ac9c-492e-a5cc-0de06613f914
SCIP notification number (Denmark)997246b1-459e-4ec7-bf6a-56081cfe27a4
SCIP notification number (Finland)e707f48d-4e06-401b-8812-4990f23a331f
ParameterValue
SCIP notification number (France)98d57770-6820-4582-8901-0f6f20ca5c39
SCIP notification number (Germany)854e0d9b-ee55-4440-8f99-bc29f43c91a9
SCIP notification number (Hungary)fb650acb-6862-4853-a7c6-1f454e1297d9
SCIP notification number (Italy)dd9ff4cc-127c-4353-a564-3364f513f146
SCIP notification number (Netherlands)660457c3-5f7f-457d-bd92-22d1db1f2b10
SCIP notification number (Poland)81687b15-dfd5-40ff-961d-8676755575e5
SCIP notification number (Romania)3d5d0282-ef7e-4f25-86e3-4465c4b592ae
SCIP notification number (Sweden)fbca236e-706d-40c8-9328-d64b37ca9bf5
CommunicationsPROFINET
Connection technology: communication/fieldbus2 x D-coded M12; 4-pole
Interface standard10BASE-T/100BASE-TX; potential-free
Autonegotiation; autocrossoveryes
PROFINET IO featuresPROFINET IO device; 2-port switch, LLDP, MRP, SNMP
ParameterInput filter
DiagnosticsUndervoltage; Overcurrent; Overload; Overtemperature
Device functionsBluetooth®
VisualizationAndroid/iOS app
Number of digital inputs8
Number of digital outputs8
Connection technology: inputs / outputs8 x M8; 3-pole
Signal type (voltage)24 VDC
Input characteristicType 3, per IEC 61131-2
Input filter0.2 20 ms
Output current (per channel)2 A (typ.) for DO
Supply current per port1L/2L: 4 A (max.)
Connection technology: supply2 x L-coded M12; 5-pole
Supply voltage24 VDC (18 … 31.2 V); 1L/2L
Current consumption (max.)16000mA
Current consumption (note)per supply line; overload- and short-circuit-protected
Reverse voltage protectionYes

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp