Industrial Automation Parts. Prompt replies from real people.

WAGO 750-344 Controllers Bus Couplers I/O

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the WAGO 750-344?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 750-344 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
750-344
Material Number
—
Manufacturer
WAGO
Product ID
44615

Get a Free Quote

Request pricing and availability for 750-344.

More parts to source? Send your whole list in one enquiry

Key specifications

Communications
INTERBUS
Supply voltage (system)
24 VDC (-15 +20 %); via pluggable connector
Weight
115.5g
Ambient temperature (operation)
0 … +55 °C
Protection type
IP20
See all specifications

Product Highlights

  1. INTERBUS Communication: Supports up to 256 fieldbus nodes, 4,096 I/O points, and 64 modules per node, with a maximum bus segment length of 400 m over certified Cu cable
  2. Transmission Performance: 500 kBd transmission rate with a typical transmission time of 1.43 ms for 10 couplers each with 32 digital I/O
  3. Power Supply: 24 VDC (-15 +20 %) system supply via pluggable connector, 350 mA current consumption at 5 V system supply, 650 mA total system supply current, and 80 % typical efficiency at nominal load
  4. Compact DIN-Rail Housing: 49.5 x 96.8 x 71.9 mm light gray polycarbonate/polyamide 6.6 housing, 115.5 g weight, 64.7 mm depth from DIN-rail upper edge, and DIN-35 rail mounting
  5. Environmental and Compliance: CE marked, EN 50254 compliant, IP20 protection, 0 to +55 °C operating temperature, 95 % relative humidity without condensation, and RoHS compliant with exemption 6(c)
750-344

Product Information

Technical Specifications

Specifications for 750-344

ParameterValue
CommunicationsINTERBUS
Number of fieldbus nodes on master (max.)256
Number of I/O points4,096
Transmission rate500 kBd
Bus segment length (max.)400 m
Transmission medium (communication/fieldbus)Certified Cu cable
Transmission time1.43 ms (10 couplers; each 32 digital I/O)
Number of modules per node (max.)64
Number of modules without a bus extension (max.)64
Input and output process image (fieldbus) max.20 bytes/20 bytes
Supply voltage (system)24 VDC (-15 +20 %); via pluggable connector
Current consumption (5 V system supply)350mA
Total current (system supply)650mA
Input current (typ.) at nominal load (24 V)260mA
Power supply efficiency (typ.) at nominal load (24 V)80%
StandardEN 50254
Connection technology: communication/fieldbusINTERBUS: 1 x D-Sub 9 plug / D-Sub 9 socket
Connection technology: system supply4 x CAGE CLAMP®
Connection type 1System supply
Solid conductor0.08 1.5 mm2 / 28 16 AWG
Fine-stranded conductor0.08 1.5 mm2 / 28 16 AWG
Strip length5 6 mm / 0.2 0.24 inches
Note (conductor cross-section)14 AWG: THHN, THWN
Connection technology: device configuration1 x Male connector; 4-pole
Width49.5 mm / 1.949 inches
Height96.8 mm / 3.811 inches
Depth71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail64.7 mm / 2.547 inches
Mounting typeDIN-35 rail
Colorlight gray
Housing materialPolycarbonate; polyamide 6.6
Fire load2.359MJ
Weight115.5g
Conformity markingCE
Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 2000 m / 0 6562 ft
ParameterValue
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95%
Vibration resistanceper IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-4
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity < 75%10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%25ppm
Product Group15 (I/O System)
eCl@ss 10.027-24-26-07
eCl@ss 9.027-24-26-07
ETIM 9.0EC001603
ETIM 8.0EC001603
ECCNNO US CLASSIFICATION
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
Customs tariff number8517620090
CAS-No.1303-86-2
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)487c962b-863c-438e-acd9-e2fee5bf0d62
SCIP notification number (Belgium)1bb5405a-3bac-40e3-8c0a-ec2318a54e3a
SCIP notification number (Bulgaria)be0ca790-521c-4fa7-aa3f-bafecd5a6419
SCIP notification number (Czech Republic)da292d4b-8dd0-4376-ab4c-46e07b0b9bee
SCIP notification number (Denmark)c43f63b1-4cc5-4250-b2da-ecde71b436c2
SCIP notification number (Finland)fd73eeb2-a497-4e6f-8ae1-d3f81b66f83a
SCIP notification number (France)3201d43f-92d3-49cc-8c4e-af12feea2ea4
SCIP notification number (Germany)5386bad6-0295-4279-9677-609e690550b1
SCIP notification number (Hungary)323377eb-891b-4e3e-bd71-e34c28a8d226
SCIP notification number (Italy)123b0170-d5ec-46ea-ba62-836a35e6ec72
SCIP notification number (Netherlands)ea8420bd-7450-49e8-b1b8-87fe19954dd1
SCIP notification number (Poland)cf15a2fe-3687-4a83-8f47-34fccaffb512
SCIP notification number (Romania)09ee24c2-011c-45fa-94ed-a2b791d1c51a
SCIP notification number (Sweden)3972b5a1-e41a-4ef2-95a5-5b255a792a1b

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.