- 289-509
WAGO 289-509 interface module for DIN-35 rail mounting, supplied as a mounting carrier. It provides a 64-pole DIN 41651 male pluggable connector on the system side and double-row PCB terminal blocks on the field side, using CAGE CLAMP® connection technology (WAGO 236 Series). Field-side conductors accept 0.08 to 2.5 mm2 (28 to 12 AWG) solid or fine-stranded wire, with a strip length of 5 to 6 mm. Operating voltage is up to AC/DC 125 V, nominal current 1 A, rated voltage 125 V, pollution degree 2, functional insulation, and dielectric strength of 0.75 kVrms (AC, 1 min.). Dimensions are 170 mm wide, 85 mm high, and 36 mm deep from the upper DIN-rail edge. Protection type IP00; live parts can be touched, so the equipment manufacturer must provide protection against direct contact. Ambient operating temperature is -20 to +55 °C.
- 289-510
WAGO 289-510 interface module in a mounting carrier for DIN-35 rail. It has a 64-pole DIN 41651 male pluggable connector, vertical mating direction, and triple-row PCB terminal blocks on the field side using CAGE CLAMP® connection (WAGO 236 Series). Field-side conductors accept 0.08 … 2.5 mm2 / 28 … 12 AWG solid or fine-stranded, with 5 … 6 mm strip length. Operating voltage is ≤ AC/DC 125 V, rated voltage 125 V, nominal current 1 A, pollution degree 2. Dielectric strength channel/channel is 1.3 kVrms for 1 min. Protection type IP00; live parts can be touched, so the equipment manufacturer must provide protection against direct contact. Dimensions are 120 mm wide, 85 mm high, 36 mm deep from the upper DIN-rail edge. Ambient temperature is -20 … +55 °C in operation and -40 … +70 °C in storage.
- 289-522
WAGO 289-522 interface module with a 64-pole DIN 41612 Type C male pluggable connector, vertical mating direction, and double-row PCB terminal blocks. Field connection uses CAGE CLAMP® technology (WAGO 236 Series) for solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 5–6 mm strip length. Rated voltage is 100 V, rated surge voltage 0.8 kV, nominal current 1 A, maximum contact resistance 20 mΩ, pollution degree 2, and IP20 protection. Contacts are gold-plated copper alloy. Operating ambient temperature is -20 to +50 °C; storage is -40 to +70 °C at 85% relative humidity, non-condensing. DIN-35 rail mounting, 171 mm wide, 85 mm high, 34 mm deep from the DIN-rail upper edge. Performance level 2, 400 mating cycles.
- 289-523
WAGO 289-523 interface module with a 64-pole pluggable connector per DIN 41612, Type C, male, mating horizontally. The field side uses double-row PCB terminal blocks with CAGE CLAMP connection technology (WAGO 236 Series), accepting solid and fine-stranded conductors from 0.08 to 2.5 mm2 (28 to 12 AWG), strip length 5 to 6 mm. Rated voltage is 50 V, nominal current 1 A, rated surge voltage 0.8 kV, maximum contact resistance 20 mOhm, pollution degree 2, performance level 2 with 400 mating cycles. Dimensions are 171 mm wide, 85 mm high, 34 mm deep from the upper DIN-rail edge, for DIN-35 rail mounting. Operating temperature is -20 to +50 C. Protection type IP00; live parts can be touched, so the equipment manufacturer must provide protection against direct contact.
- 289-526
WAGO 289-526 interface module with a 64-pole pluggable connector per DIN 41612, Type C, male. Mating direction is vertical. Field connection uses CAGE CLAMP® technology (WAGO 236 Series) with double-row PCB terminal blocks, accepting 0.08 to 2.5 mm² (28 to 12 AWG) solid or fine-stranded conductors; strip length 5 to 6 mm. Rated voltage 100 V, rated surge voltage 0.8 kV, nominal current 1 A, maximum contact resistance 20 mΩ, pollution degree 2. Connector contacts are gold-plated copper alloy. Dimensions: 171 mm wide, 85 mm high, 34 mm deep from the upper DIN-rail edge; DIN-35 rail mounting. Ambient operating temperature -20 to +50 °C, storage -40 to +70 °C, 85% relative humidity non-condensing. Protection type IP20. Weight 154.5 g.
- 289-531
WAGO 289-531 interface module, 64-pole, with a Type C female pluggable connector per DIN 41612 and vertical mating direction. Field connection uses CAGE CLAMP® technology (WAGO 236 Series) for solid and fine-stranded conductors from 0.08 to 2.5 mm2 (28 to 12 AWG), strip length 5 to 6 mm. Rated voltage 100 V; nominal current 1 A; maximum contact resistance 20 mOhm; rated surge voltage 0.8 kV; pollution degree 2; IP20. Contacts are gold-plated copper alloy. Mounting is on DIN-35 rail via a mounting carrier, 171 mm wide, 85 mm high, 34 mm deep from the upper DIN-rail edge. Operating ambient temperature -20 to +50 °C; storage -40 to +70 °C; relative humidity 85% non-condensing. Performance level 2, 400 mating cycles. Weight 164.4 g.
- 289-542
WAGO 289-542 interface module, 25-pole, with a D-subminiature male connector and vertical mating direction. Field connection uses CAGE CLAMP® technology with WAGO 236 Series PCB terminal blocks (triple-row), accepting solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG) with a strip length of 5–6 mm. Operating voltage is ≤ AC/DC 125 V, rated voltage 125 V, nominal current 2 A, rated surge voltage 0.8 kV, maximum contact resistance 30 mΩ, pollution degree 2, and basic insulation. Connector contacts are Au over Ni. Performance level is 2 / 200 mating cycles. Dimensions: 72 mm width, 85 mm height, 34 mm depth from upper DIN-rail edge; DIN-35 rail mounting. Protection type IP20. Ambient temperature: -20 to +50 °C operation, -40 to +70 °C storage, 85% relative humidity non-condensing. Conforms to EN 61010-2-201.
- 289-544
WAGO 289-544 interface module with a 50-pole D-subminiature male connector and vertical mating direction, mounted on a DIN-35 rail. Field connection uses CAGE CLAMP® technology (WAGO 236 Series) with triple-row PCB terminal blocks; accepted conductors are 0.08 to 2.5 mm² (28 to 12 AWG), strip length 5 to 6 mm. Operating voltage is ≤ AC/DC 125 V, rated voltage 125 V, nominal current 2 A, maximum contact resistance 30 mΩ, dielectric strength 0.75 kVrms AC for 1 minute, functional insulation, pollution degree 2, and performance level 2 (200 mating cycles). Dimensions are 94 mm wide, 85 mm high, and 34 mm deep from the upper DIN-rail edge. Operating temperature is -20 to +50 °C; storage is -40 to +70 °C at 85% relative humidity, non-condensing. Protection type IP00; live parts can be touched, so direct-contact protection must be provided by the equipment manufacturer. Specified to EN 61010-2-201.