- 2002-2731
WAGO 2002-2731 rail chassis terminal block for DIN-rail 35 x 15 and 35 x 7.5 mounting. Through/through terminal block suitable for Ex e II applications. The product identity and technical data are as stated; no further ratings, certifications, or accessories are specified.
- 2002-2791
WAGO 2002-2791 end plate for rail chassis terminal blocks, gray, 0.8 mm (0.031 in) wide, 91.9 mm (3.618 in) high, and 47.7 mm (1.878 in) deep, with snap-on mounting. Main housing insulation is polyamide (PA66), material group I, flammability class V0 per UL94, fire load 0.089 MJ, weight 3 g. Tested to DIN EN 50155 (VDE 0115-200):2022-06 for railway rolling stock electronic equipment and to DIN EN 61373 (VDE 0115-0106):2011-04 for shock and vibration, service life test Category 1, Class A/B, frequency f1 = 5 Hz to f2 = 150 Hz, acceleration 5g, 5 h per axis on X, Y and Z axes. RoHS compliant, no exemption.
- 2002-2792
WAGO 2002-2792 is an orange end plate for rail chassis terminal blocks, supplied in a 0.8 mm width with a height of 91.9 mm and a depth of 47.7 mm. It uses snap-on mounting and weighs 3 g. The main housing insulation material is polyamide (PA66), material group I, with a flammability class of V0 per UL94. Railway test specifications include DIN EN 50155 (VDE 0115-200):2022-06 and DIN EN 61373 (VDE 0115-0106):2011-04. Vibration testing covers f1 = 5 Hz to f2 = 150 Hz at 5 g, 5 h per axis in X, Y and Z axes; shock testing uses a half sine form with 30 ms duration and 3 positive and 3 negative shocks per axis. RoHS status is compliant, no exemption.
- 2002-2951
WAGO 2002-2951 is a gray double-deck, double-disconnect rail chassis terminal block in the TOPJOB S product group (22). It provides 4 clamping units, 4 potentials, 2 levels, and 2 jumper slots, with L/L potential marking and side marking. Mounting is on DIN-35 rail. Dimensions are 5.2 mm width, 108 mm height, and 42 mm depth from the upper DIN-rail edge. Connection uses Push-in CAGE CLAMP with operating-tool actuation for copper conductors; nominal cross-section is 2.5 mm2, strip length 10 to 12 mm, front-entry wiring. Ratings include 400 V and 16 A at overvoltage category III / pollution degree 3, with 6 kV rated impulse voltage. Housing is polyamide PA66, UL94 V0, 17.3 g.
- 2002-2954
WAGO 2002-2954 rail chassis terminal block, blue, double-deck with two pivoting knife disconnects and N/N potential marking. Four clamping units, four potentials, two levels, two jumper slots. Push-in CAGE CLAMP connection, front-entry wiring, operating tool actuation, copper conductors, 2.5 mm² nominal cross-section, 10–12 mm strip length. DIN-35 rail mounting. Width 5.2 mm, height 108 mm, depth from DIN-rail upper edge 42 mm. Rated voltage 400 V, rated impulse voltage 6 kV, rated current 16 A at overvoltage category III / pollution degree 3. Polyamide PA66 housing, UL94 V0, operating temperature -60 to +105 °C. Ratings: ATEX KIWA 17 ATEX 0030 U, IECEx KIWA 17.0014U (Ex ec IIC Gc). UL and CSA ratings differ by use group.
- 2002-2958
WAGO 2002-2958 is a gray double-deck rail chassis terminal block in Product Group 22 (TOPJOB S). It provides 4 clamping units across 2 levels, 3 total potentials, and 2 jumper slots, with potential marking L/L and side marking. Dimensions are 5.2 mm width, 108 mm height, and 42 mm depth from the upper DIN-rail edge; mounting is on DIN-35 rail. Connection uses Push-in CAGE CLAMP® with operating-tool actuation for copper conductors, nominal cross-section 2.5 mm2, strip length 10 to 12 mm, front-entry wiring. Ratings include 400V and 16A at III/3, 6kV impulse, and UL/CSA 300V, 15A. Housing is polyamide PA66, UL94 V0, fire load 0.312MJ, weight 17.7g. Operating temperature is -60 to +105 °C.
- 2002-2961
WAGO 2002-2961 is a gray double-deck carrier terminal block for DIN-35 rail mounting, 5.2 mm wide, 108 mm high, 40.6 mm deep from the upper DIN-rail edge. It provides four clamping units, two levels, five potentials, and two jumper slots, with side marking and L/L potential marking. Connection uses Push-in CAGE CLAMP with operating-tool actuation for copper conductors, nominal cross-section 2.5 mm2, strip length 10 to 12 mm, front-entry wiring. Ratings: 400 V, 6 kV impulse, 16 A (III/3); UL Use Groups B and C 300 V, 15 A; CSA Use Group C 150 V, 15 A. Housing is polyamide PA66, UL94 V0, operating -60 to +105 °C. Approvals include CSA 22.2 No 158 and ATEX/IECEx Ex ec IIC Gc.
- 2002-2963
WAGO 2002-2963 is a gray double-deck carrier terminal block for DIN-35 rail mounting, 5.2 mm wide, with four clamping units, five potentials, and two jumper slots. Connection uses Push-in CAGE CLAMP® with operating-tool actuation for copper conductors, nominal cross-section 2.5 mm2, front-entry wiring, strip length 10 to 12 mm. Ratings: 400 V, 6 kV impulse, 16 A at overvoltage category III / pollution degree 3; UL Use Groups B and C 300 V, 15 A; CSA Use Group C 150 V, 15 A. Housing is polyamide PA66, UL94 V0, operating temperature -60 to +105 °C. ATEX KIWA 17 ATEX 0030 U and IECEx KIWA 17.0014U (Ex ec IIC Gc).