- 855-4209/200-001
WAGO 855-4209/200-001 split-core current transformer for current measurement. Primary rated current 60 A, voltage output 333 mV, accuracy class 1, rated frequency 50 to 60 Hz. Feedthrough for measurement conductor Ø 18 mm; split-core (suspended) mounting. Secondary connection via CAGE CLAMP® with WAGO 221-2411 connector, lever actuation, strip length 11 mm; solid conductor 0.2 to 4 mm² (20 to 14 AWG), fine-stranded 0.2 to 4 mm² (18 to 14 AWG). Highest voltage for equipment Um AC 720 Vrms; test voltage AC 3 kV, 50 Hz, 1 min. Rated continuous thermal current 100 percent; rated short-time thermal current 60 x IN / 1 s; rated surge current 2.5 x Ith. IP20. Dimensions 59.6 x 82.6 x 44.6 mm; weight 285 g. Operating temperature -10 to +55 °C. Standard EN 61869-1; CE marking.
- 855-5001/1000-000
WAGO 855-5001/1000-000 split-core current transformer for current measurement, suspended mounting. Primary rated current 1000 A, secondary rated current 1 A, rated power 0.5 VA, accuracy class 0.5, rated frequency 50 to 60 Hz. Rated continuous thermal current 100 percent; rated short-time thermal current 60 x IN for 1 s; rated surge current 2.5 x Ith. Highest voltage for equipment Um AC 720 Vrms. Test voltage AC 3 kV at 50 Hz for 1 min. Feedthrough for measurement conductor 42 mm. Cable 2 x 0.5 mm2, fine-stranded, 5 m, brown S1 and blue S2. Dimensions 66.2 x 97 x 66 mm; weight 696 g. IP20. Ambient operation -10 to +40 °C, storage -20 to +70 °C, relative humidity 5 to 85 percent without condensation, altitude up to 2000 m. CE; EN 61869-1.
- 855-5001/250-001
WAGO 855-5001/250-001 is a split-core current transformer for current measurement, with a 250 A primary rated current and 1 A secondary rated current. It has accuracy class 1 and rated power Sr 0.5 VA at a rated frequency of 50 to 60 Hz. The feedthrough for the measurement conductor is 42 mm. The cable is 2 x 0.5 mm2, fine-stranded, 5 m long, with brown = S1 and blue = S2. Dimensions are 66.2 mm width, 97 mm height, and 66 mm depth; weight is 672 g. Highest voltage for equipment Um is AC 720 Vrms. Test voltage is AC 3 kV at 50 Hz for 1 min. Protection type is IP20. Operating ambient temperature is -10 to +55 °C, storage -20 to +70 °C, relative humidity 5 to 85 % without condensation, and maximum operating altitude 2000 m. Standards/specifications: EN 61869-1. Conformity marking: CE.
- 855-5001/400-000
WAGO 855-5001/400-000 split-core current transformer for current measurement. Primary rated current 400 A, secondary rated current 1 A, rated power 0.5 VA, accuracy class 0.5. Rated frequency 50 to 60 Hz. Highest voltage for equipment Um AC 720 Vrms. Rated continuous thermal current 100 percent, rated short-time thermal current 60 x IN for 1 s, rated surge current 2.5 x Ith. Test voltage AC 3 kV at 50 Hz for 1 min. Feedthrough for measurement conductor 42 mm. Cable 2 x 0.5 mm2 fine-stranded, 5 m, brown = S1, blue = S2. IP20, CE, EN 61869-1. Dimensions 66.2 x 97 x 66 mm, 672 g. Operating temperature -10 to +55 C, storage -20 to +70 C, relative humidity 5 to 85 percent without condensation, maximum operating altitude 2000 m.
- 855-5001/600-000
WAGO 855-5001/600-000 split-core current transformer for current measurement, suspended mounting. Primary rated current 600 A, secondary rated current 1 A, rated power 0.5 VA, accuracy class 0.5, rated frequency 50 to 60 Hz. Rated continuous thermal current 100%, rated short-time thermal current 60 x IN for 1 s, rated surge current 2.5 x Ith. Highest voltage for equipment Um AC 720 Vrms; test voltage AC 3 kV at 50 Hz for 1 min. Feedthrough for measurement conductor 42 mm. Cable 2 x 0.5 mm2 fine-stranded, 5 m, brown = S1, blue = S2. Dimensions 66.2 x 97 x 66 mm; weight 611 g. Protection type IP20. Ambient temperature -10 to +55 C operation, -20 to +70 C storage; relative humidity 5 to 85% without condensation; operating altitude up to 2000 m. CE marking; EN 61869-1.
- 855-5005/1000-000
WAGO 855-5005/1000-000 is a split-core current transformer for current measurement, with a primary rated current of 1000 A and a secondary rated current of 5 A. Accuracy class is 0.5, rated power Sr is 0.5 VA, and rated frequency is 50 to 60 Hz. The measurement conductor feedthrough is 42 mm. Connection uses a 3 m cable, 2 x 1.5 mm2 fine-stranded, with color code black = S1 and red = S2. Highest voltage for equipment Um is AC 720 Vrms; test voltage is AC 3 kV, 50 Hz, 1 min. Protection type is IP20. Dimensions are 66.2 mm wide, 97 mm high, and 66 mm deep; weight is 618 g. Operating ambient temperature is -10 to +40 °C. Standards/specifications: EN 61869-1. Conformity marking: CE.
- 855-5005/400-001
WAGO 855-5005/400-001 split-core current transformer for current measurement, suspended mounting. Primary rated current 400 A, secondary rated current 5 A, rated power 0.5 VA, accuracy class 1, rated frequency 50 to 60 Hz. Highest voltage for equipment Um AC 720 Vrms; test voltage AC 3 kV at 50 Hz for 1 min. Rated continuous thermal current 100 percent, rated short-time thermal current 60 x IN for 1 s, rated surge current 2.5 x Ith. Feedthrough for measurement conductor 42 mm. Cable 2 x 1.5 mm2, fine-stranded, 3 m, black S1 and red S2. IP20; dimensions 66.2 x 97 x 66 mm; 525.6 g. Operating ambient -10 to +55 C. Conforms to EN 61869-1; CE marking.
- 855-505/1000-1001
WAGO 855-505/1000-1001 is a closed current transformer for current measurement. Primary rated current is 1000 A with a 5 A secondary, 10 VA rated power, and accuracy class 1. Rated frequency is 50 to 60 Hz. The measurement conductor feedthrough is Ø 44 mm. Dimensions are 85 mm width, 105.25 mm height, and 52 mm depth; weight is 366 g. Connection technology is CAGE CLAMP, with 9 to 10 mm strip length and 0.08 to 4 mm² (28 to 12 AWG) solid and fine-stranded conductors. Test voltage is AC 6 kV at 50 Hz for 1 min; highest voltage for equipment Um is AC 1.2 kVrms. Insulation class E. Operating ambient temperature is -5 to +50 °C.