- 2002-476
WAGO 2002-476 is an insulated 6-way staggered jumper for rail-mounted terminal blocks, with jumper assignment 1-2-3-4-5-6. Width is 29.9 mm (1.177 inches), weight 3 g, color light gray, fire load 0.04 MJ. Rated current is 25 A; rated voltage (III / 3) is 400 V and rated impulse voltage (III / 3) is 6 kV. It is RoHS compliant with no exemption. Railway testing includes DIN EN 50155 (VDE 0115-200):2022-06 and DIN EN 61373 (VDE 0115-0106):2011-04, covering vibration at f1= 5 Hz to f2= 150 Hz, 5g acceleration, 5 h per axis, and half-sine shock of 30 ms.
- 2002-480
WAGO 2002-480 is a light gray staggered jumper for rail chassis terminal blocks, part of Product Group 22 (TOPJOB S). It has a width of 50.8 mm / 2 inches and a jumper assignment of 1-2-3-4-5-6-7-8-9-10. Electrical ratings are 400V rated voltage (III / 3), 6kV rated impulse voltage (III / 3), and 25A rated current. Weight is 5g and fire load is 0.018MJ. It is RoHS compliant with no exemption. Railway testing includes DIN EN 50155 (VDE 0115-200):2022-06 and DIN EN 61373 (VDE 0115-0106):2011-04, covering vibration at f1= 5 Hz to f2= 150 Hz, 5g acceleration, 5 h per axis, and half-sine shock of 30 ms.
- 2002-481
WAGO 2002-481 is a light-gray, insulated staggered jumper with an 11-way configuration and a jumper assignment of 1-2-3-4-5-6-7-8-9-10-11. It measures 56 mm (2.205 inches) in width and weighs 5.5 g. The product group is 22 (TOPJOB S). Electrical ratings are 400 V rated voltage (III / 3), 6 kV rated impulse voltage (III / 3), and 25 A rated current. Fire load is 0.02 MJ. It is RoHS compliant with no exemption. Railway test specifications include DIN EN 50155 (VDE 0115-200):2022-06 and DIN EN 61373 (VDE 0115-0106):2011-04. Vibration testing covers f1 = 5 Hz to f2 = 150 Hz at 5 g for 5 h per axis in X, Y, and Z axes; shock testing uses a half-sine form with 30 ms duration and 3 positive and 3 negative shocks per axis.
- 2002-481/011-000
WAGO 2002-481/011-000 rail chassis terminal block, light gray, 56 mm (2.205 in) wide, 5.5 g. Rated voltage (III/3) 400 V, rated impulse voltage (III/3) 6 kV, rated current 25 A. Jumper assignment 1-3-5-7-9-11. Fire load 0.02 MJ. Tested to DIN EN 50155 (VDE 0115-200):2022-06 for railway rolling stock electronic equipment and DIN EN 61373 (VDE 0115-0106):2011-04 for shock and vibration, spectrum service life test Category 1, Class A/B, frequency 5 Hz to 150 Hz, acceleration 5g, 5 h per axis on X, Y and Z axes. RoHS compliant, no exemption. Packaging: bag, 25 pcs.
- 2002-482
WAGO 2002-482 is a 12-way staggered jumper in the TOPJOB S product group (22), with a jumper assignment of 1-2-3-4-5-6-7-8-9-10-11-12 and a width of 61.2 mm (2.409 inches). It is light gray and weighs 6.1 g, with a fire load of 0.021 MJ. Electrical ratings are 400 V rated voltage (III / 3), 6 kV rated impulse voltage (III / 3), and 25 A rated current. It is RoHS compliant with no exemption. Railway test specifications include DIN EN 50155 (VDE 0115-200):2022-06 and DIN EN 61373 (VDE 0115-0106):2011-04, covering vibration at 5 Hz to 150 Hz, 5 g, 5 h per axis, and half-sine shocks of 30 ms.
- 2002-492
WAGO 2002-492 is an insulated double-deck vertical jumper for 2002 series rail-mount terminal blocks. It measures 3.3 mm wide, 3.9 mm high, and 37.8 mm deep, and is supplied in light gray. Rated voltage is 500 V (III/3), rated impulse voltage is 6 kV (III/3), and rated current is 24 A. Fire load is 0.005 MJ and weight is 0.8 g. It is RoHS compliant with no exemption. Railway test specifications include DIN EN 50155 (VDE 0115-200):2022-06 and DIN EN 61373 (VDE 0115-0106):2011-04. Vibration testing covers 5 Hz to 150 Hz at 5 g for 5 h per axis in X, Y, and Z axes. Packaging is a bag of 25 pieces.
- 2002-492/000-012
WAGO 2002-492/000-012 is an orange double-deck vertical jumper in the 2002 series. Dimensions are 3.3 mm width, 3.9 mm height, and 37.8 mm depth, with a weight of 0.8 g and fire load of 0.006 MJ. Electrical ratings are 500 V rated voltage (III/3), 6 kV rated impulse voltage (III/3), and 24 A rated current. It is RoHS compliant with no exemption. Railway rolling stock testing includes DIN EN 50155 (VDE 0115-200):2022-06 and DIN EN 61373 (VDE 0115-0106):2011-04, covering vibration at 5 Hz to 150 Hz, 5 g, 5 h per axis in X, Y, and Z, plus half-sine shock of 30 ms, 3 positive and 3 negative shocks per axis. Supplied in bags of 25 pieces.
- 2002-511
WAGO 2002-511 rail chassis terminal block, product group 22 (TOPJOB S), gray, single-pole, side-entry wiring. Push-in CAGE CLAMP connection, operating tool actuation, copper conductors only. Nominal cross-section 2.5 mm2; solid and fine-stranded 0.25–4 mm2 (22–12 AWG); fine-stranded with insulated ferrule 0.25–2.5 mm2 (22–14 AWG). Strip length 10–12 mm. Width 5.2 mm. Rated voltage 500 V, rated impulse voltage 6 kV, rated current 24 A at overvoltage category III / pollution degree 3. UL/CSA ratings 300 V, 20 A (Use Groups B and C); approvals per CSA 22.2 No 158. Polyamide PA66 housing, UL94 V0, fire load 0.071 MJ, weight 2.7 g. Per EN 61984, do not mate or unmate under load.