- 855-301/075-201
WAGO 855-301/075-201 is a closed current transformer for current measurement, with a 75 A primary rated current and 1 A secondary rated current. Rated frequency is 50 to 60 Hz, rated power Sr is 2.5 VA, and accuracy class is 1. The measurement conductor feedthrough is Ø 26 mm. Rated continuous thermal current Icth is 1.2 x IN; rated short-time thermal current Ith is 60 x IN/1 s (max. 100 kA/1 s). Test voltage is AC 6 kV, 50 Hz, 1 min. Highest voltage for equipment Um is AC 1.2 kVrms. Dimensions are 60 mm width, 80.9 mm height, and 52 mm depth; weight is 230 g. Operation ambient temperature is -5 to +50 °C. Conformity marking is CE; standards/specifications list EN 61869-1.
- 855-301/100-201
WAGO 855-301/100-201 is a closed current transformer in the Signal Conditioners category. It has a feedthrough for the measurement conductor of Ø 26 mm and a highest voltage for equipment Um of AC 1.2 kVrms. Test voltage is AC 6 kV at 50 Hz for 1 min. Insulation class is E. Dimensions are 60 mm width, 80.9 mm height, and 52 mm depth; weight is 230 g. Operating ambient temperature is -5 to +50 °C, storage temperature is -25 to +70 °C, and maximum operating altitude is 1000 m. Conformity marking is CE, and the supplied standard is EN 61869-1.
- 855-301/150-501
WAGO 855-301/150-501 is a closed current transformer for current measurement. Primary rated current is 150 A with a 1 A secondary rated current, 5 VA rated power, and accuracy class 1. Rated frequency is 50 to 60 Hz. The measurement conductor feedthrough is Ø 26 mm. Rated continuous thermal current Icth is 1.2 x IN; rated short-time thermal current Ith is 60 x IN/1 s (max. 100 kA/1 s). Test voltage is AC 6 kV, 50 Hz, 1 min. Highest voltage for equipment Um is AC 1.2 kVrms. Insulation class E. Dimensions are 60 mm width, 80.9 mm height, and 52 mm depth; weight 230 g. Ambient operating temperature is -5 to +50 °C and storage temperature is -25 to +70 °C. Maximum operating altitude is 1000 m. Connection technology is CAGE CLAMP. Conformity marking CE; standards/specifications EN 61869-1.
- 855-301/200-501
WAGO 855-301/200-501 plug-in current transformer with a closed mounting type, rated 200 A primary to 1 A secondary, rated frequency 50 to 60 Hz, rated power 5 VA, accuracy class 1. Test voltage AC 6 kV at 50 Hz for 1 min; highest voltage for equipment Um AC 1.2 kVrms. Feedthrough for measurement conductor Ø 26 mm. Dimensions 60 mm width, 80.9 mm height, 52 mm depth; weight 230 g. Ambient temperature -5 to +50 °C operation, -25 to +70 °C storage; operating altitude max. 1000 m. CAGE CLAMP connection, strip length 9 to 10 mm, conductors 0.08 to 4 mm² (28 to 12 AWG). Standards/specifications: EN 61869-1. Conformity marking: CE.
- 855-301/250-501
WAGO 855-301/250-501 plug-in current transformer for current measurement, with 250 A primary rated current and 1 A secondary rated current. Rated power is 5 VA, accuracy class 1, rated frequency 50 to 60 Hz. Rated continuous thermal current is 1.2 x IN; rated short-time thermal current is 60 x IN/1 s (max. 100 kA/1 s). Overcurrent limiting factor is FS5/FS10 (type dependent; see type plate inscription). Test voltage is AC 6 kV; 50 Hz; 1 min. Highest voltage for equipment Um is AC 1.2 kVrms. Feedthrough for measurement conductor is Ø 26 mm. Dimensions are 60 mm width, 80.9 mm height, and 52 mm depth; weight 282 g. Connection technology is CAGE CLAMP®. Conforms to EN 61869-1.
- 855-301/400-1001
WAGO 855-301/400-1001 closed current transformer for current measurement. Primary rated current 400 A, secondary rated current 1 A, rated power 10 VA, accuracy class 1, rated frequency 50 to 60 Hz. Rated continuous thermal current 1.2 x IN; rated short-time thermal current 60 x IN/1 s (max. 100 kA/1 s). Overcurrent limiting factor FS5/FS10, type dependent; see type plate inscription. Highest voltage for equipment Um AC 1.2 kVrms. Test voltage AC 6 kV, 50 Hz, 1 min. Feedthrough for measurement conductor diameter 26 mm. Insulation class E. CAGE CLAMP connection, strip length 9 to 10 mm, solid and fine-stranded conductors 0.08 to 4 mm2 (28 to 12 AWG). Dimensions 60 x 80.9 x 52 mm. Weight 230 g. Operating ambient temperature -5 to +50 °C; storage -25 to +70 °C; maximum operating altitude 1000 m. Conforms to EN 61869-1, CE marked.
- 855-301/600-1001
WAGO 855-301/600-1001 closed current transformer for current measurement. Primary rated current 600 A, secondary rated current 1 A, rated power 10 VA, accuracy class 1, rated frequency 50 to 60 Hz. Rated continuous thermal current 1.2 x IN; rated short-time thermal current 60 x IN / 1 s (max. 100 kA / 1 s). Overcurrent limiting factor FS5 / FS10, type dependent; see type plate inscription. Feedthrough for measurement conductor Ø 26 mm. Test voltage AC 6 kV, 50 Hz, 1 min. Highest voltage for equipment Um AC 1.2 kVrms. Insulation class E. Connection technology CAGE CLAMP, strip length 9 to 10 mm, solid and fine-stranded conductors 0.08 to 4 mm2 (28 to 12 AWG). Dimensions 60 x 80.9 x 52 mm. Weight 230 g. Ambient temperature -5 to +50 °C operation, -25 to +70 °C storage. Operating altitude max. 1000 m. CE marking. Standard EN 61869-1.
- 855-305/050-103
WAGO 855-305/050-103 plug-in current transformer. Primary rated current 50 A, secondary rated current 5 A, rated power Sr 1.25 VA, accuracy class 3. Rated frequency 50 … 60 Hz. Closed current transformer with Ø 26 mm feedthrough for the measurement conductor. Rated continuous thermal current Icth 1.2 x IN; rated short-time thermal current Ith 60 x IN/1 s (max. 100 kA/1 s). Highest voltage for equipment Um AC 1.2 kVrms; test voltage AC 6 kV, 50 Hz, 1 min. Insulation class E. CAGE CLAMP connection, strip length 9 10 mm, solid and fine-stranded conductors 0.08 4 mm2 (28 12 AWG). Dimensions 60 x 80.9 x 52 mm, weight 300 g. Ambient temperature -5 … +50 °C operation, -25 … +70 °C storage. Conforms to EN 61869-1; CE marking.