- 756-5302/060-100
WAGO 756-5302/060-100 is a 10 m, 5-pole sensor/actuator cable with an M12 A-coded socket, 90° cable outlet, and free end. Electrical ratings include 250 VAC/DC operating voltage, 4 A operating current, 1.5 kV rated surge voltage, contact resistance 10 mΩ, and conductor resistance < 57 Ω/km. The cable uses a Li9YC11Y-HF 5x0.34 mm2 construction with bare copper conductors (7 x 0.25 mm), halogen-free PE insulation, tinned copper braid shielding at approximately 80 % optical coverage, and a black halogen-free PUR sheath. Protection type is IP67; pollution degree 3 per VDE 0110. Ambient operating temperature is -50 … +90 °C static and -25 … +90 °C dynamic. Tightening torque is 1 Nm.
- 756-5311/030-015
WAGO 756-5311/030-015 is a 3-pole sensor/actuator cable, 1.5 m long, with an M12 A-coded plug and a free end. The cable connection direction to the mating direction is 0°. Electrical ratings are 250 VAC/DC operating voltage, 4 A operating current, 2.5 kV rated surge voltage, insulation resistance greater than 10^9 Ω, and contact resistance 10 mΩ. Protection type is IP67, and pollution degree is 3 per VDE 0110. The cable uses fine-stranded bare copper conductors (42 x 0.1 mm), halogen-free PP9Y insulation, and a black halogen-free PUR sheath, flame resistant per IEC 332-2. Operating temperature is -50 to +90 °C static and -25 to +90 °C dynamic. Tightening torque is 1 Nm.
- 756-5311/030-020
WAGO accessory cable 756-5311/030-020 is a 3-pole M12 A-coded plug to free-end sensor/actuator cable, 2 m long. Rated operating voltage is 250 VAC/DC at 4 A, with a rated surge voltage of 2.5 kV, insulation resistance greater than 109 ohm, contact resistance of 10 milliohm, and conductor resistance of 60 ohm/km or less. Protection type is IP67, and pollution degree is 3 per VDE 0110. Static operating temperature range is -50 to +90 degrees C; dynamic range is -25 to +90 degrees C. The PUR sheath is halogen-free per DIN VDE 0472 Part 815, flame resistant per IEC 332-2, and self-extinguishing. Minimum bending radius is 10 times cable diameter, with 2 million bending cycles.
- 756-5311/030-050
WAGO 756-5311/030-050 is a 3-pole sensor/actuator cable with an M12 plug, A-coded, connected to a free end. Cable length is 5 m. Operating voltage is 250 VAC/DC and operating current is 4 A; rated surge voltage is 2.5 kV. Contact resistance is 10 mΩ and conductor resistance is ≤ 60 Ω/km. Protection type is IP67. Static operating temperature range is -50 … +90 °C; dynamic range is -25 … +90 °C. The cable uses fine-stranded bare copper conductors (42 x 0.1 mm), halogen-free PP9Y insulation, and a black halogen-free PUR sheath, flame resistant per IEC 332-2, self-extinguishing. Minimum bending radius is 10 x cable diameter, with 2 Mio. bending cycles. Tightening torque is 1 Nm.
- 756-5311/030-100
WAGO 756-5311/030-100 is a 3-pole sensor/actuator cable with an M12 A-coded plug and free end, 10 m long. It is rated for 250 VAC/DC and 4 A, with a rated surge voltage of 2.5 kV, insulation resistance greater than 10^9 Ω, and contact resistance of 10 mΩ. The cable uses fine-stranded bare copper conductors (42 x 0.1 mm) with halogen-free PP9Y insulation and a black halogen-free PUR sheath. Protection type is IP67. Static operating temperature range is -50 to +90 °C; dynamic range is -25 to +90 °C. Minimum bending radius is 10 times cable diameter, with 2 million bending cycles. Tightening torque is 1 Nm.
- 756-5311/060-015
WAGO sensor/actuator cable 756-5311/060-015, 1.5 m, with a 5-pole A-coded M12 plug and free end. Operating voltage is 250 VAC/DC and operating current is 4 A. Rated surge voltage is 1.5 kV; insulation resistance is greater than 109 Ω and contact resistance is 10 mΩ. Protection type is IP67. Static operating temperature range is -50 to +90 °C; dynamic range is -25 to +90 °C. Minimum bending radius is 10 x cable diameter, with 2 million bending cycles. The black PUR sheath is halogen-free per DIN VDE 0472 Part 815 and flame resistant per IEC 332-2. Conductor configuration is bare copper, fine-stranded (42 x 0.1 mm). Tightening torque is 1 Nm. RoHS status is compliant with exemption 6(c).
- 756-5311/060-050
WAGO 756-5311/060-050 is a 5 m sensor/actuator cable with a 5-pole M12 A-coded plug and free end, connection direction 0°. Operating voltage is 250 VAC/DC at 4 A, with 1.5 kV rated surge voltage, insulation resistance greater than 109 Ω, contact resistance 10 mΩ, and conductor resistance ≤ 60 Ω/km. Protection type is IP67; pollution degree 3 per VDE 0110. Static operating temperature is -50 to +90 °C, dynamic -25 to +90 °C. The PUR sheath is halogen-free per DIN VDE 0472 Part 815 and flame resistant per IEC 332-2. Minimum bending radius is 10 x cable diameter, with 2 million bending cycles.
- 756-5311/060-100
WAGO 756-5311/060-100 is a 10 m, 5-pole sensor/actuator cable with an M12 A-coded straight plug and free end. It has a PUR sheath, black, halogen-free per DIN VDE 0472 Part 815, flame resistant per IEC 332-2 and self-extinguishing, with PP9Y halogen-free conductor insulation and bare copper fine-stranded conductors (42 x 0.1 mm). Operating voltage is 250 VAC/DC at 4 A, rated surge voltage 1.5 kV, insulation resistance greater than 109 ohms, contact resistance 10 milliohms, conductor resistance up to 60 ohms/km, and protection type IP67. Operating temperature is -50 to +90 degrees C static and -25 to +90 degrees C dynamic. Minimum bending radius is 10 times cable diameter, with 2 million bending cycles and 180-degree torsional capacity.