Industrial Automation Parts. Prompt replies from real people.

WAGO 857-369 Relay Module

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 857-369?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 857-369 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
857-369
Material Number
—
Manufacturer
WAGO
Product ID
43303

Get a Free Quote

Request pricing and availability for 857-369.

More parts to source? Send your whole list in one enquiry

Key specifications

Rated voltage
300V
Rated surge voltage
4kV
Protection type
IP20
Weight
31.9g
Ambient temperature (operation at UN)
-25 … +70 °C
Nominal frequency range (input voltage)
50 … 60 HzAC / 0 HzDC
See all specifications

Product Highlights

  1. Input Voltage: AC/DC 24 to 230 V nominal, with an input voltage range of -30 to +10 %
  2. Input Current: 4 mA at 230 VAC and 20 mA at 24 VDC nominal
  3. Contact Configuration: One changeover contact with AgNi + Au contact material and a 6 A limiting continuous current
  4. Switching Capacity: Maximum resistive switching power of AC 1500 VA, AC-15 3 A at AC 250 V, and DC-13 2 A at DC 24 V
  5. Gold Contact Limitation: Switching voltage must not exceed 30 V and current must not exceed 50 mA to prevent damage to the gold layer
  6. Timing: Typical pull-in time 15 ms, drop-out time 25 ms, and bounce time 3.5 ms
  7. Service Life: Electrical life of 50 x 10^3 operations at NO resistive load and 23 °C, mechanical life of 5 x 10^6 operations
  8. Connection: Push-in CAGE CLAMP connection for solid and fine-stranded conductors from 0.34 to 2.5 mm² (22 to 14 AWG), with 9 to 10 mm strip length
  9. Insulation: Reinforced insulation between control and load circuits, double insulation between adjacent devices of the same type, and basic insulation to adjacent devices of different types
  10. Dielectric Strength: 3.51 kVrms between control and load circuits and 1 kVrms across open contacts for 1 minute at AC
  11. Rated Voltage: 300 V rated voltage, 4 kV rated surge voltage, overvoltage category III, and pollution degree 2 for mains circuits
  12. Protection and Mounting: IP20 protection, DIN-35 rail mounting, and horizontal or vertical mounting position
  13. Dimensions: 6 mm width, 94 mm height, and 81 mm depth from the upper edge of the DIN-rail
  14. Ambient Conditions: Operating temperature -25 to +70 °C, storage temperature -40 to +70 °C, relative humidity 5 to 85 % without condensation, and maximum operating altitude 2000 m
  15. Housing Material: Polyamide (PA66) main housing with UL94 V0 flammability class and 0.544 MJ fire load
  16. Compliance: EN 50121-3-2, RoHS compliant with exemption 6(c), and REACH candidate list substance 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
857-369

Product Information

Technical Specifications

Specifications for 857-369

ParameterValue
Safety informationAdjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements.
NoteTo prevent damaging the gold layer, 30 V switching voltages and 50 mA currents must not be exceeded. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life.
Rated voltage300V
Rated surge voltage4kV
Type of circuitsMains circuits
Overvoltage categoryIII
Pollution degree2
Dielectric strength (control/load circuit) (AC, 1 min)3.51 kVrms
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Insulation type (control/load circuit)Reinforced insulation (safe isolation)
Insulation type (between adjacent devices of the same type)Double insulation (safe isolation)
Insulation type (to adjacent devices of different types)Basic insulation
Protection typeIP20
Connection technologyPush-in CAGE CLAMP®
Solid conductor0.34 2.5 m㎡/ 22 14 AWG
Fine-stranded conductor0.34 2.5 m㎡/ 22 14 AWG
Fine-stranded conductor; with insulated ferrule0.34 1.5 m㎡/ 22 16 AWG
Strip length9 10 mm / 0.35 0.39 inches
Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail81 mm / 3.189 inches
Mounting typeDIN-35 rail
Mounting positionHorizontal (standing/lying); vertical
Note (material data)Information on material specifications can be found here
Insulation material (main housing)Polyamide (PA66)
Material groupI
Flammability class per UL94V0
Fire load0.544MJ
Weight31.9g
Ambient temperature (operation at UN)-25 … +70 °C
Ambient temperature (storage)-40 … +70 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≤ (Tambient+ 30 K)
Relative humidity5 85 % (no condensation permissible)
Operating altitude (max.)2000m
Standards/specificationsEN 50121-3-2
WAGO Basic Relay857-151
eCl@ss 10.027-37-16-01
eCl@ss 9.027-37-16-01
ETIM 9.0EC001437
ETIM 8.0EC001437
ECCNNO US CLASSIFICATION
ParameterValue
PU (SPU)25(1)pcs
Packaging typebox
Country of originDE
GTIN4050821854241
Customs tariff number8536490050
CAS-No.1303-86-2
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)0891d92a-b9b0-4855-a374-3f4c7d8bcec6
SCIP notification number (Belgium)3d6ce96b-95c2-45ca-9c75-c48432a5185f
SCIP notification number (Bulgaria)3eb596a0-fb70-479d-aa2f-992ee8d6da2a
SCIP notification number (Czech Republic)b067e2e6-b27e-489d-b6ce-e8a58bf12ab3
SCIP notification number (Denmark)736ec7f4-e597-4f9a-9f8d-e6e1d89224cb
SCIP notification number (Finland)0e46608a-ada5-42bc-a1e2-3cd98f6f5117
SCIP notification number (France)ce145d34-e7ee-4421-ba57-5016df2c4aa9
SCIP notification number (Germany)cf5584f3-5fcd-4275-b373-70c672f11f18
SCIP notification number (Hungary)7b26aae5-cb7d-40b7-becb-f97e3d03ff32
SCIP notification number (Italy)d63eee63-1ca0-49a7-bcf1-e4345d48419d
SCIP notification number (Netherlands)ce9882fe-9872-4be0-9614-5bcdf964b46a
SCIP notification number (Poland)1482eef4-4a89-4cd2-bd10-fe7e0efba63f
SCIP notification number (Romania)a3805355-5493-4993-bb06-a6fab5877d65
SCIP notification number (Sweden)75a7959b-0f84-4330-8630-470a2d3b43e1
Nominal input voltage UNAC/DC 24 230 V
Input voltage range-30 +10 %
Nominal input current at UN4 mA (230 VAC);?20 mA (24 VDC)
Nominal frequency range (input voltage)50 … 60 HzAC / 0 HzDC
Number of changeover contacts1
Contact material (relay)AgNi + Au
Limiting continuous current6 A
Inrush current (resistive) max.(AC) 20 A?/ 0.02?s
Switching Voltage, Max.AC 250 V
Switching power (resistive) max.AC 1500 VA; DC (see load limit curve)
Switching capacityAC-15:?3 A?/ AC 250 V; DC-13:?2 A?/ DC 24 V
Recommended minimum load1 V?/ 1 mA?/ 1 mW
Pull-in time (typ.)15ms
Drop-out time (typ.)25ms
Bounce time (typ.)3.5ms
Electrical life (NO; resistive load; 23 °C)50?x 103 switching operations
Mechanical life5?x 10? switching operations
Switching frequency with/without load (max.)6 min-1/ 60 min-1
Status indicatorYellow LED