- 753-661/000-003
WAGO 753-661/000-003 is a fail-safe digital input module with 4 channels and 4 digital inputs, operating at 24 VDC via PROFIsafe V2. The PROFIsafe address is adjustable via DIP switch or engineering software. Sensor connection is 4 x fail-safe input with test pulse; input characteristic is clock sensitive, with typical input current of 2.2 mA per channel at signal 1 and maximum signal frequency of 50 Hz. Achievable safety classes are SIL 3, Category 4, PL e, per IEC 61508-1 -7, EN ISO 13849-1, and EN 62061. Field supply is 24 VDC SELV/PELV (-15 +20 %) via power jumper contacts. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-661/000-004
WAGO 753-661/000-004 is a fail-safe 4-channel digital input module for 24 VDC voltage signals, with 4 fail-safe inputs using test pulse. It supports PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET); the PROFIsafe address is adjustable via DIP switch or engineering software. Input characteristic is Type 1 per IEC 61131, typical input current 3 mA per channel at signal 1, maximum signal frequency 50 Hz, output current 0.1 A per channel. Achievable safety classes are SIL 3, Category 4, PLe (two-channel) and SIL 2, Category 2, PLd (one-channel), per IEC 61508-1 -7, EN ISO 13849-1 and EN 62061. Mounting is DIN-35 rail; width 12 mm, height 100 mm, depth 67.8 mm. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-662/000-003
WAGO 753-662/000-003 is an 8-channel fail-safe digital input module for the I/O system, with PROFIsafe V2 communication and a PROFIsafe address adjustable via DIP switch or engineering software. Inputs are clock-sensitive, rated 24 VDC, with 8 fail-safe sensor connections with test pulse, typical input current 2.2 mA per channel at signal 1, and maximum signal frequency 50 Hz. System supply is 5 VDC via data contacts at 148 mA; field supply is 24 VDC SELV/PELV (-15 +20 %) via power jumper contacts, 20 mA with no external load. Achievable safety classes are SIL 3, Category 4, PL e, per IEC 61508-1 -7, EN ISO 13849-1, and EN 62061. Connections are 16 x CAGE CLAMP for 0.08-2.5 mm2 (28-14 AWG), strip length 9-10 mm. Dimensions are 24 mm wide, 100 mm high, 69 mm deep, for DIN-35 rail mounting. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-666/000-003
WAGO 753-666/000-003 is a fail-safe digital input/output module with 4 digital inputs and 2 digital outputs, 6 channels total. Inputs are fail-safe with test pulse, clock sensitive, 24 VDC, typical input current 2.2 mA per channel at signal 1, maximum signal frequency 50 Hz. Outputs are power outputs, fail-safe with test pulse, 10 A per channel, 20 A per module, short-circuit-protected; maximum switching frequency 50 Hz resistive and 0.1 Hz inductive. Protocol: PROFIsafe V2, address adjustable via DIP switch or engineering software. Achievable safety classes: SIL 3, Category 4, PL e; safety standards IEC 61508-1 -7, EN ISO 13849-1, EN 62061. Field supply 24 VDC (-15 +30 %). Dimensions 24 mm wide, 100 mm high, 69 mm deep; DIN-35 rail mounting. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-667/000-003
WAGO 753-667/000-003 is a fail-safe digital input/output module with 4 clock-sensitive inputs and 4 power outputs, 8 channels total. Inputs are fail-safe with test pulse, 24 VDC, 2.2 mA typical per channel at signal 1, maximum signal frequency 50 Hz. Outputs are fail-safe with test pulse, short-circuit-protected, 2 A per channel and 8 A per module. Switching frequency is 50 Hz for resistive load and 0.1 Hz for inductive load. Field supply is 24 VDC SELV/PELV (-15 to +20 percent); system supply is 5 VDC via data contacts. Protocol is PROFIsafe V2, with address adjustable via DIP switch or engineering software. Achievable safety classes are SIL 3, Category 4, PL e. Pluggable connectors and coding fingers (753 Series) are not included.
- 753-667/000-004
WAGO 753-667/000-004 is a fail-safe digital input/output module with 8 channels: 4 fail-safe digital inputs with test pulse and 4 fail-safe power outputs with test pulse. Inputs are 24 VDC, Type 1 per IEC 61131, 3 mA typical per channel at signal 1, 50 Hz maximum. Outputs are short-circuit-protected, 2 A per channel, 8 A per module, with maximum switching frequency 50 Hz resistive, 0.1 Hz inductive, and 0.1 Hz capacitive. Field supply is 24 VDC SELV/PELV (-25 to +20 percent). Achievable safety classes are SIL 3, Category 4, PLe two-channel and SIL 2, Category 2, PLd one-channel, per IEC 61508-1 to -7, EN ISO 13849-1, and EN 62061. Protocols include PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET). Pluggable connectors and coding fingers (753 Series) are not included.
- 753-668/000-004
WAGO 753-668/000-004 I/O module for controllers and bus couplers. It provides four analog input channels with 0/4 … 20 mA differential inputs and supports PROFIsafe communication. The module uses a fail-safe design.
- 756-1201/060-020
WAGO 756-1201/060-020 is a shielded 2 m Ethernet cable assembly with a straight D-coded M12 plug and a free end. It has 4 poles, an operating voltage of 250 V, an operating current of 4 A, and a rated surge voltage of 2 kV. Contact resistance is 10 mΩ and conductor resistance is less than 57 Ω/km. The cable uses a 02YH(ST)C11Y 2x2x0.75/1.5-100 LI GN VZN FRNC shielded type, with bare copper conductors (7 x 0.25 mm), halogen-free PE insulation, and a halogen-free PUR sheath, flame resistant per IEC 60332-1-2. Protection type is IP67, operating temperature is -40 to +70 °C, and pollution degree is 3/2 per IEC 60664-1. Bending cycles are 3Mio.