Product Model
2606-3359
Material Number
—
Manufacturer
WAGO
Product ID
42006

Get a Free Quote

Request pricing and availability for 2606-3359.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
53.9g
Continuous operating temperature
-60 … +105 °C
Rated voltage (III / 3)
800V
Rated impulse voltage (III / 3)
8kV
Rated current
41A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Pole count: 9-position wire-to-board terminal block
  2. Connection type: Push-in CAGE CLAMP with lever actuation
  3. Conductor range: solid and fine-stranded 0.2 to 10 mm² (24 to 8 AWG), strip length 11 to 13 mm
  4. Pin spacing: 12.5 mm / 0.492 inches
  5. Dimensions: width 109.0 mm / 4.291 inches, height 31 mm / 1.22 inches, height from surface 27 mm / 1.063 inches, depth 24 mm / 0.945 inches
  6. PCB contact: THT with solder pin arrangement over the entire terminal strip (in-line), 2 solder pins per potential, solder pin length 4 mm, solder pin dimensions 1.5 x 1.2 mm, drilled hole diameter with tolerance 2(+0.1) mm
  7. Insulation material: Polyamide (PA66), flammability class per UL94 V0
  8. Clamping spring material: chrome-nickel spring steel (CrNi), contact material: electrolytic copper (ECu), contact plating: tin
  9. Temperature range: limit and continuous operating -60 to +105 °C, processing -35 to +60 °C
  10. Ratings: rated voltage 800 V (III/3), 1000 V (III/2 and II/2), rated current 41 A, rated impulse voltage 8 kV
  11. Approvals: UL 600 V / 42 A (Use Groups B and C), CSA 600 V / 31 A (Use Groups B and C)
  12. Railway compliance: DIN EN 50155, DIN EN 61373 shock and vibration tests passed
2606-3359

Product Information

Technical Specifications

Specifications for 2606-3359

ParameterValue
Variants:Other pole numbers
Clamping units9
Total number of potentials9
Number of connection types1
Number of levels1
Pin spacing12.5 mm / 0.492 inches
Width109.0 mm / 4.291 inches
Height31 mm / 1.22 inches
Height from the surface27 mm / 1.063 inches
Depth24 mm / 0.945 inches
Solder pin length4mm
Solder pin dimensions1.5 x 1.2 mm
Drilled hole diameter with tolerance2(+0.1)mm
PCB contactTHT
Solder pin arrangementover the entire terminal strip (in-line)
Number of solder pins per potential2
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Clamping spring materialChrome-nickel spring steel (CrNi)
Contact materialElectrolytic copper (ECu)
Contact platingTin
Fire load0.731MJ
Actuator colororange
Weight53.9g
Limit temperature range-60 … +105 °C
Processing temperature-35 … +60 °C
Continuous operating temperature-60 … +105 °C
ETIM 9.0EC002643
ETIM 8.0EC002643
ECCNNO US CLASSIFICATION
PU (SPU)22 pcs
Packaging typebox
Country of originPL
GTIN4055143862196
Customs tariff number8536904000
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60664-1
Rated voltage (III / 3)800V
Rated impulse voltage (III / 3)8kV
Rated voltage (III/2)1000V
Rated surge voltage (III/2)8kV
Nominal voltage (II/2)1000V
Rated surge voltage (II/2)8kV
Rated current41A
Legend (ratings)(III2) ≙ Overvoltage category IIIPollution degree 2
ParameterValue
Approvals perCSA
Rated voltage UL (Use Group B)600V
Rated current UL (Use Group B)42A
Rated voltage UL (Use Group C)600V
Rated current UL (Use Group C)42A
Rated voltage CSA (Use Group B)600V
Rated current CSA (Use Group B)31A
Rated voltage CSA (Use Group C)600V
Rated current CSA (Use Group C)31A
Connection technologyPush-in CAGE CLAMP®
Actuation typeLever
Solid conductor0.2 10 m㎡/ 24 8 AWG
Fine-stranded conductor0.2 10 m㎡/ 24 8 AWG
Fine-stranded conductor; with insulated ferrule0.25 6 mm2
Fine-stranded conductor; with uninsulated ferrule0.25 6 mm2
Fine-stranded conductor; with twin ferrule0.25 2.5 mm2
Strip length11 13 mm / 0.43 0.51 inches
Conductor connection direction to PCB90°
Number of poles9
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.