- 232-410/026-000
WAGO 232-410/026-000 is a 10-pole, angled female PCB connector for conductor connection using CAGE CLAMP® technology. It has a 5.08 mm pin spacing, 10 clamping units, and accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with a strip length of 8–9 mm. Dimensions are 53.2 mm wide, 19.9 mm high, and 22.75 mm deep; weight is 18.8 g. The orange PA66 housing is rated UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamps. Ratings per IEC/EN 60664-1: 320 V, 4 kV impulse, 14 A. UL ratings: 300 V, 15 A (Use Group B); 300 V, 10 A (Use Group D); 600 V, 15 A per UL 1977. CSA ratings: 300 V, 15 A (Use Group B); 300 V, 10 A (Use Group D). Limit temperature range is -60 to +85 °C.
- 232-411/026-000
WAGO 232-411/026-000 is an 11-position PCB interconnect female connector for conductor connection, using CAGE CLAMP® actuation with an operating tool. It has 5.08 mm pin spacing, an angled design, 90° conductor entry to mating direction, and variable coding. Dimensions are 58.28 mm width, 19.9 mm height, and 22.75 mm depth. The orange PA66 housing is rated UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. It accepts 0.08 to 2.5 mm2 (28 to 12 AWG) solid and fine-stranded conductors, with 8 to 9 mm strip length. Ratings per IEC/EN 60664-1 include 320 V (III/3), 4 kV impulse, and 14 A. Limit temperature range is -60 to +85 °C; processing temperature is -35 to +60 °C. Per DIN EN 61984, these connectors must not be connected or disconnected when live or under load.
- 232-412/026-000
WAGO 232-412/026-000 is a 12-pole, angled female PCB connector for conductor termination, using CAGE CLAMP connection with an operating tool. Pin spacing is 5.08 mm (0.2 in); dimensions are 63.36 mm width, 19.9 mm height, and 22.75 mm depth. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 8–9 mm strip length. The housing is orange polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamps. Rated current is 14 A; rated voltage 320 V (III/3), rated impulse voltage 4 kV, per IEC/EN 60664-1. Limit temperature range is -60 to +85 °C. RoHS compliant. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 232-413/026-000
WAGO 232-413/026-000 is an angled 13-pole female PCB connector for conductor connection, using CAGE CLAMP® technology with operating-tool actuation parallel or perpendicular to conductor entry. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 8–9 mm strip length. Pin spacing is 5.08 mm; dimensions are 68.44 mm wide, 19.9 mm high, and 22.75 mm deep. The housing is orange polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 14 A; rated voltage is 320 V (III/3) and 630 V (II/2), per IEC/EN 60664-1. Limit temperature range is -60 to +85 °C. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 232-414/026-000
WAGO 232-414/026-000 is an angled female PCB connector for conductor termination, part of the MCS MULTI CONNECTION SYSTEM. It has 14 poles, 14 clamping units, and 5.08 mm pin spacing, with a width of 73.52 mm, height of 19.9 mm, and depth of 22.75 mm. Connection uses CAGE CLAMP technology with an operating tool; solid and fine-stranded conductors accept 0.08 to 2.5 mm2 (28 to 12 AWG), strip length 8 to 9 mm. The housing is orange polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts. Ratings per IEC/EN 60664-1: 320 V (III/3), 4 kV impulse, 14 A. Limit temperature range is -60 to +85 C. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 232-415/026-000
WAGO 232-415/026-000 is an angled female PCB connector in the MCS MULTI CONNECTION SYSTEM with 15 poles and 5.08 mm pin spacing. It uses CAGE CLAMP connection technology with an operating tool, accepting solid and fine-stranded conductors from 0.08 to 2.5 mm2 (28 to 12 AWG), strip length 8 to 9 mm. Dimensions are 78.6 mm width, 19.9 mm height, and 22.75 mm depth. The housing is orange polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 14 A; rated voltage 320 V (III/3), 320 V (III/2), and 630 V (II/2), with 4 kV rated impulse voltage per IEC/EN 60664-1. Limit temperature range is -60 to +85 C. Per DIN EN 61984, these connectors must not be connected or disconnected when live or under load.
- 232-416/026-000
WAGO 232-416/026-000 is an angled 16-pole female PCB connector for conductor connection, using CAGE CLAMP actuation with an operating tool. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 8–9 mm strip length. Pin spacing is 5.08 mm; dimensions are 83.68 mm width, 19.9 mm height, and 22.75 mm depth. The orange PA66 housing is UL94 V0 rated, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 14 A; rated voltage is 320 V (III/3) and 630 V (II/2), per IEC/EN 60664-1. Limit temperature range is -60 to +85 °C. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 232-417/026-000
WAGO 232-417/026-000 is a 17-pole, single-level, angled female PCB connector for conductor termination, using CAGE CLAMP® connection technology with operating-tool actuation. It has 5.08 mm pin spacing, dimensions of 88.76 mm width, 19.9 mm height, and 22.75 mm depth, and accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28 to 12 AWG), with 8 to 9 mm strip length. The housing is orange polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 14 A; rated voltage is 320 V (III/3), 320 V (III/2), and 630 V (II/2), with 4 kV rated impulse voltage. Limit temperature range is -60 to +85 °C. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.