Q1Can you supply the WAGO 2060-952/028-000?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 2060-952/028-000 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
2060-952/028-000
Material Number
—
Manufacturer
WAGO
Product ID
41516

Get a Free Quote

Request pricing and availability for 2060-952/028-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
0.5g
Rated voltage (III / 3)
63V
Rated impulse voltage (III / 3)
2.5kV
Rated current
9A
Number of poles
2
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Compatibility: Suitable for SMD PCB terminal blocks (2060 Series), only for 2060-45x, not for 2060-40x
  2. Configuration: 2 potentials and 2 poles with 4 mm / 0.157 in pin spacing
  3. Dimensions: Width 7.4 mm / 0.291 in, height 2.6 mm / 0.102 in, depth 28 mm / 1.102 in
  4. Materials: Polyamide (PA66) insulation, material group I, UL94 V0 flammability class, copper alloy contacts with silver plating
  5. Electrical ratings: 9 A rated current, 63 V rated voltage (III/3), 160 V (III/2), 320 V nominal (II/2), 2.5 kV rated impulse/surge voltage, 250 V / 9 A per UL 1977
  6. Temperature range: -60 to +105 °C
  7. Durability: Maximum 10 mating cycles (connections/disconnections)
  8. Railway compliance: Tested to DIN EN 50155, DIN EN 61373 (shock and vibration, Category 1, Class A/B, 5 Hz to 150 Hz, 5 g, 5 h per axis, X/Y/Z axes, 30 ms half-sine shocks, 3 positive and 3 negative per axis)
  9. RoHS: Compliant, no exemption
  10. Weight: 0.5 g, fire load 0.003 MJ
2060-952/028-000

Product Information

Technical Specifications

Specifications for 2060-952/028-000

ParameterValue
Safety informationNotice:Only suitable for 2060-45x, not for 2060-40x.
Total number of potentials2
Pin spacing4 mm / 0.157 inches
Width7.4 mm / 0.291 inches
Height2.6 mm / 0.102 inches
Depth28 mm / 1.102 inches
Mating cycles (max.)10
Number of mating cycles10 connections/disconnections (max.)
Suitablefor SMD PCB terminal blocks (2060 Series)
Note (material data)Information on material specifications can be found here
Colorwhite
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Contact materialCopper alloy
Contact platingSilver
Fire load0.003MJ
Weight0.5g
Limit temperature range-60 … +105 °C
eCl@ss 10.027-14-11-92
eCl@ss 9.027-14-11-92
ETIM 9.0EC002848
ETIM 8.0EC002848
ECCNNO US CLASSIFICATION
PU (SPU)500 pcs
Packaging typebox
Country of originCN
GTIN4055143303859
Customs tariff number8536908585
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60664-1
Rated voltage (III / 3)63V
Rated impulse voltage (III / 3)2.5kV
Rated voltage (III/2)160V
ParameterValue
Rated surge voltage (III/2)2.5kV
Nominal voltage (II/2)320V
Rated surge voltage (II/2)2.5kV
Rated current9A
Legend (ratings)(III2) ≙ Overvoltage category IIIPollution degree 2
Rated voltage (UL 1977)250V
Rated current UL 19779A
Number of poles2
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.