Product Model
2022-182
Material Number
—
Manufacturer
WAGO
Product ID
40965

Get a Free Quote

Request pricing and availability for 2022-182.

More parts to source? Send your whole list in one enquiry

Key specifications

Anti-rotation protection
Yes
Weight
3.2g
Rated voltage (III / 3)
690V
Rated impulse voltage (III / 3)
6kV
Rated current
24A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Connection Technology: Push-in CAGE CLAMP® with operating tool actuation and front-entry wiring
  2. Conductor Range: Nominal cross-section 2.5 mm², solid and fine-stranded conductors 0.25–4 mm² (22–12 AWG), fine-stranded with insulated ferrule 0.25–2.5 mm² (22–14 AWG), strip length 10–12 mm
  3. Electrical Ratings: IEC/EN 61984 rated voltage 690 V, rated impulse voltage 6 kV, rated current 24 A (32 A at maximum conductor cross-section), overvoltage category III / pollution degree 3, UL and CSA 600 V, 20 A
  4. Housing and Dimensions: Orange polyamide (PA66) housing, UL94 V0 flammability class, width 5.2 mm, height 40.5 mm, depth 22.4 mm, weight 3.2 g
  5. Mechanical and Coding Features: 1-pole, 1 clamping unit, 1 potential, variable coding, anti-rotation protection, no mismating protection, plugging without loss of pin spacing
  6. Temperature Range: Processing -35 to +85 °C, continuous operating -60 to +105 °C
  7. Railway Compliance: Tested to DIN EN 50155 and DIN EN 61373 for rolling stock equipment, including shock and vibration tests at 5–150 Hz and 5 g, 30 ms half-sine shocks, with contact-fault monitoring and voltage-drop measurements passed
2022-182

Product Information

Technical Specifications

Specifications for 2022-182

ParameterValue
Safety informationAccording to EN 61984, pluggable connectors without current interrupting capacity must not be mated or unmated when live or under load.
Clamping units1
Total number of potentials1
Width5.2 mm / 0.205 inches
Height40.5 mm / 1.594 inches
Depth22.4 mm / 0.882 inches
Variable codingYes
Marking levelSide marking
Anti-rotation protectionYes
Contact type (pluggable connector)Female connector/socket
Connector (connection type)for conductor
Mismating protectionNo
Plugging without loss of pin spacingYes
Note (material data)Information on material specifications can be found here
Colororange
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.053MJ
Weight3.2g
Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C
Product Group18 (X-COM-System)
eCl@ss 10.027-14-11-06
eCl@ss 9.027-14-11-06
ETIM 9.0EC001284
ETIM 8.0EC001284
ECCNNO US CLASSIFICATION
PU (SPU)250 pcs
Packaging typeBox
Country of originCN
GTIN4050821243410
Customs tariff number8536698000
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 61984
Rated voltage (III / 3)690V
Rated impulse voltage (III / 3)6kV
Rated current24A
Current at conductor cross-section (max.) mm232A
Legend (ratings)(III3) ≙ Overvoltage category IIIPollution degree 3
Approvals perCSA 22.2 No 158
Rated voltage UL (Use Group B)600V
ParameterValue
Rated current UL (Use Group B)20A
Rated voltage UL (Use Group C)600V
Rated current UL (Use Group C)20A
Rated voltage CSA (Use Group C)600V
Rated current CSA (Use Group C)20A
Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section2.5 mm2
Solid conductor0.25 4 m㎡/ 22 12 AWG
Solid conductor; push-in termination0.75 4 m㎡/ 18 12 AWG
Fine-stranded conductor0.25 4 m㎡/ 22 12 AWG
Fine-stranded conductor; with insulated ferrule0.25 2.5 m㎡/ 22 14 AWG
Fine-stranded conductor; with ferrule; push-in termination1 2.5 m㎡/ 18 14 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length10 12 mm / 0.39 0.47 inches
Number of poles1
Wiring directionFront-entry wiring
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed