- 731-515/008-000
WAGO 731-515/008-000 is a gray, angled female PCB connector for panel mounting, with 15 poles and 5 mm pin spacing. It uses CAGE CLAMP connection technology with an operating tool, accepting solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), and fine-stranded conductors with insulated ferrules from 0.25 to 1.5 mm² or uninsulated ferrules from 0.25 to 2.5 mm². Strip length is 7 to 8 mm. Dimensions are 76.5 mm wide, 17.6 mm high (13.1 mm from the surface), and 23 mm deep. The housing is polyamide (PA66), UL94 V0, with chrome-nickel spring steel clamping springs and tin-plated copper alloy contacts. Rated current is 12 A; rated voltage is 320 V (III/3), 320 V (III/2), and 630 V (II/2), with 4 kV rated impulse voltage. Limit temperature range is -60 to +85 °C.
- 731-516/031-000
WAGO 731-516/031-000 is a 16-pole, single-level female PCB connector for conductor connection, using CAGE CLAMP® technology with an operating tool. It has an angled, feed-through mountable design with 5 mm pin spacing, 90° conductor entry to mating direction, and anti-rotation protection. Dimensions are 94.8 mm width, 13.1 mm height, and 23 mm depth. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 7–8 mm strip length. The gray PA66 housing is UL94 V0 rated. Ratings per IEC/EN 60664-1 include 320 V and 12 A. Limit temperature range is -60 to +85 °C. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 731-518/031-000
WAGO 731-518/031-000 is an angled, 18-pole female PCB connector for conductor connection using CAGE CLAMP® technology. It has 18 clamping units on one level, 5 mm pin spacing, and overall dimensions of 104.8 mm width, 13.1 mm height, and 23 mm depth. Conductors from 0.08 to 2.5 mm² (28–12 AWG) solid or fine-stranded are accepted; strip length is 7–8 mm. The housing is gray polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 12 A. Ratings per IEC/EN 60664-1 include 320 V (III/3), 4 kV impulse, and 630 V (II/2). UL ratings include 300 V, 15 A (Use Group B) and 300 V, 10 A (Use Group D). Limit temperature range is -60 to +85 °C; processing temperature is -35 to +60 °C. Mounting is feed-through, with anti-rotation protection and no locking.
- 731-519/008-000
WAGO 731-519/008-000 is a 19-pole PCB interconnect female connector with angled sockets, 5 mm (0.197 in) pin spacing, and panel mounting via snap-in mounting feet. Dimensions are 96.5 mm width, 17.6 mm height, 13.1 mm height from the surface, and 23 mm depth. Connection technology is CAGE CLAMP with operating-tool actuation parallel to conductor entry. Solid and fine-stranded conductors accept 0.08 to 2.5 mm² (28 to 12 AWG); strip length is 7 to 8 mm. Rated current is 12 A, with rated voltage 320 V (III/3) and rated impulse voltage 4 kV, per IEC/EN 60664-1. Housing is gray polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts. Limit temperature range is -60 to +85 °C.
- 731-532/008-000
WAGO 731-532/008-000 is a gray, angled, panel-mount female connector for conductors, part of the MCS MULTI CONNECTION SYSTEM. It uses CAGE CLAMP® connection technology with two clamping units and two poles on one level, accepting solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG). Pin spacing is 7.5 mm; dimensions are 14 mm wide, 17.6 mm high, 23 mm deep, with 13.1 mm height from the surface. The housing is polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 12 A. Rated voltage is 500 V (III/3), 630 V (III/2), and 1000 V (II/2), with 6 kV rated impulse voltage. Limit temperature range is -60 to +85 °C. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 731-533/031-000
WAGO 731-533/031-000 is a 3-pole, angled female PCB connector for conductor termination, using CAGE CLAMP® connection technology with an operating tool. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with a strip length of 7–8 mm. Pin spacing is 7.5 mm; dimensions are 34.8 mm wide, 13.1 mm high, and 23 mm deep. The housing is gray polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 12 A; rated voltage is 500 V (III/3) and 630 V (III/2) per IEC/EN 60664-1. Limit temperature range is -60 to +85 °C. Mounting is feed-through; anti-rotation protection is provided. Per DIN EN 61984, these connectors must not be connected or disconnected when live or under load.
- 731-534/031-000
WAGO 731-534/031-000 is a gray, angled, 4-pole female PCB connector for conductor connection using CAGE CLAMP® technology, actuated by an operating tool parallel to conductor entry. It has a 7.5 mm pin spacing, 42.3 mm width, 13.1 mm height, and 23 mm depth, with feed-through mounting and anti-rotation protection. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with a 7–8 mm strip length. Ratings per IEC/EN 60664-1 include 500 V (III/3), 630 V (III/2), 1000 V (II/2), 6 kV impulse, and 12 A. UL ratings: 300 V, 15 A (Use Group B); 300 V, 10 A (Use Group D); 600 V, 15 A (UL 1977). CSA ratings: 300 V, 15 A (B); 300 V, 10 A (D). Housing is PA66, UL94 V0; contacts are tin-plated copper alloy. Limit temperature range is -60 to +85 °C.
- 731-535/008-000
WAGO 731-535/008-000 is a 5-pole angled female PCB connector with CAGE CLAMP connection technology, panel mounting, and snap-in mounting feet. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with a strip length of 7 to 8 mm. Pin spacing is 7.5 mm; dimensions are 36.5 mm width, 17.6 mm height, and 23 mm depth. The housing is gray polyamide (PA66), UL94 V0, with tin-plated copper alloy contacts and chrome-nickel spring steel clamping springs. Rated current is 12 A; rated voltage is 500 V (III/3) and 630 V (III/2), per IEC/EN 60664-1. Limit temperature range is -60 to +85 °C. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.