- 723-606/018-000
WAGO 723-606/018-000 is a light gray 6-pole male connector/plug for conductor connection using CAGE CLAMP technology, actuated with an operating tool parallel or perpendicular to conductor entry. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 8–9 mm strip length. Pin spacing is 7.5 mm; dimensions are 45.7 mm wide, 18.8 mm high, 27.5 mm deep. It provides panel mounting, anti-rotation and mismating protection, variable coding, and no plug-in locking. Ratings per IEC/EN 60664-1: 500 V (III/3), 630 V (III/2), 1000 V (II/2), 6 kV impulse, 12 A. Limit temperature range is -60 to +100 °C.
- 723-606/019-000
WAGO 723-606/019-000 is a light gray male connector/plug in the MCS MULTI CONNECTION SYSTEM, with 6 poles and 6 clamping units on one level. It uses CAGE CLAMP connection technology with an operating tool, accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), and has a strip length of 8 to 9 mm. Pin spacing is 7.5 mm (0.295 in); dimensions are 57.3 mm wide, 14.3 mm high, and 27.5 mm deep. The housing is polyamide (PA66), flammability class V0 per UL94; contacts are electrolytic copper with tin plating. Rated current is 12 A. Limit temperature range is -60 to +100 °C. Mismating protection and variable coding are provided. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 723-606/114-000
WAGO 723-606/114-000 is a 6-pole male PCB connector for conductor connection, part of the MCS MULTI CONNECTION SYSTEM. It uses CAGE CLAMP® connection with an operating tool, accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), and has a strip length of 8 to 9 mm. Pin spacing is 7.5 mm; dimensions are 63.5 mm wide, 17.5 mm high, and 27.5 mm deep. Rated current is 12 A, with rated voltages of 500 V (III/3), 630 V (III/2), and 1000 V (II/2) per IEC/EN 60664-1. Housing is light gray Polyamide (PA66), UL94 V0; contacts are electrolytic copper with tin plating. Limit temperature range is -60 to +100 °C. Mismating protection and variable coding are provided.
- 723-607
WAGO 723-607 is a 7-pole, 1-conductor male PCB connector in the MCS MULTI CONNECTION SYSTEM with CAGE CLAMP connection and 7.5 mm pin spacing. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 8–9 mm strip length, and measures 53.2 mm wide, 14.3 mm high, and 27.5 mm deep. The light gray PA66 housing is rated UL94 V0, with tin-plated electrolytic copper contacts and chrome-nickel spring steel clamping springs. Ratings per IEC/EN 60664-1 include 500 V (III/3), 630 V (III/2), 1000 V (II/2), 6 kV impulse, and 12 A. UL ratings are 300 V/15 A (Use Group B), 300 V/10 A (Use Group D), and 600 V/15 A (UL 1977). Limit temperature range is -60 to +100 °C. Mismating protection and variable coding are provided; locking is none.
- 723-607/018-000
WAGO 723-607/018-000 is a 7-pole, single-level male connector for conductor connection in the MCS MULTI CONNECTION SYSTEM. It uses CAGE CLAMP connection technology with an operating tool, accepting solid and fine-stranded conductors from 0.08 to 2.5 mm2 (28 to 12 AWG), with a strip length of 8 to 9 mm. Pin spacing is 7.5 mm; dimensions are 53.2 mm width, 18.8 mm height, and 27.5 mm depth. The housing is light gray polyamide (PA66), UL94 V0, with tin-plated electrolytic copper contacts and chrome-nickel spring steel clamping springs. It mounts to panels, has variable coding, anti-rotation protection, and mismating protection. Limit temperature range is -60 to +100 °C. Rated current is 12 A; rated voltage is 500 V (III/3) and 630 V (III/2) per IEC/EN 60664-1. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.
- 723-608/018-000
WAGO 723-608/018-000 is an 8-pole male PCB connector for conductor connection using CAGE CLAMP technology, actuated with an operating tool. It has 8 clamping units and 8 potentials on one level, with 7.5 mm pin spacing and 60.7 mm width. Solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG) are accepted; strip length is 8–9 mm. Mounting is panel mounting with snap-in foot for 3.5(+0.1) mm drilled holes and housing sheet thickness 0.6–1.2 mm. The housing is light gray polyamide (PA66), UL94 V0, with tin-plated electrolytic copper contacts. Rated current is 12 A; rated voltage (III/3) is 500 V per IEC/EN 60664-1. Limit temperature range is -60 to +100 °C. Mismating protection and variable coding are provided.
- 723-608/019-000/035-000
WAGO 723-608/019-000/035-000 is an 8-pole, single-level male PCB connector for conductor connection, using CAGE CLAMP® spring pressure technology with an operating tool. It accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), with 8–9 mm strip length. Pin spacing is 7.5 mm; dimensions are 72.3 mm width, 14.3 mm height, and 62.5 mm depth. The housing is light gray polyamide (PA66), UL94 V0, with tin-plated electrolytic copper contacts and chrome-nickel spring steel clamping springs. Rated current is 12 A; rated voltage is 500 V (III/3) and 630 V (III/2), per IEC/EN 60664-1. Limit temperature range is -60 to +100 °C. Mismating protection and variable coding are provided; locking is none.
- 723-608/114-000
WAGO 723-608/114-000 is an 8-pole, single-level male connector for conductor connection in the MCS MULTI CONNECTION SYSTEM. It uses CAGE CLAMP® termination with an operating tool, accepts solid and fine-stranded conductors from 0.08 to 2.5 mm² (28–12 AWG), and has a strip length of 8 to 9 mm. Pin spacing is 7.5 mm; dimensions are 78.5 mm wide, 17.5 mm high, and 27.5 mm deep. The light gray PA66 housing is UL94 V0 rated, with tin-plated electrolytic copper contacts and chrome-nickel spring steel clamping springs. Ratings per IEC/EN 60664-1 include 500 V (III/3), 630 V (III/2), 1000 V (II/2), 6 kV impulse, and 12 A. Limit temperature range is -60 to +100 °C; processing temperature is -35 to +60 °C. Mismating protection and variable coding are provided. Per DIN EN 61984, these connectors have no breaking capacity and must not be connected or disconnected when live or under load.