Industrial Automation Parts. Prompt replies from real people.

WAGO 2002-1549 Terminal Blocks

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 2002-1549?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 2002-1549 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
2002-1549
Material Number
—
Manufacturer
WAGO
Product ID
40408

Get a Free Quote

Request pricing and availability for 2002-1549.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
11.3g
Rated voltage (III / 3)
400V
Rated impulse voltage (III / 3)
6kV
Rated current
16A
Rated current IN for specified power loss
16A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Connection technology: Push-in CAGE CLAMP® with operating tool actuation and front-entry wiring
  2. Conductor range: 0.25 to 4 mm² (22 to 12 AWG) solid and fine-stranded copper conductors, 2.5 mm² nominal cross-section, 10 to 12 mm strip length
  3. Ratings: 400 V rated voltage, 6 kV rated impulse voltage, 16 A rated current per IEC/EN 60947-7-1, overvoltage category III / pollution degree 3
  4. Housing: Gray polyamide (PA66) insulation, UL94 V0 flammability class, 5.2 mm width, DIN-35 rail mounting
  5. Operating temperature: -60 to +105 °C continuous, -35 to +85 °C processing
  6. Railway compliance: DIN EN 50155 and DIN EN 61373 shock and vibration tests passed, including 5 g acceleration from 5 to 150 Hz and 30 ms half-sine shocks
2002-1549

Product Information

Technical Specifications

Specifications for 2002-1549

ParameterValue
Clamping units2
Total number of potentials2
Number of levels1
Width5.2 mm / 0.205 inches
Height99.6 mm / 3.921 inches
Depth from upper-edge of DIN-rail32.9 mm / 1.295 inches
Mounting typeDIN-35 rail
Marking levelCenter/side marking
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.226MJ
Weight11.3g
Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C
Product Group22 (TOPJOB S)
eCl@ss 10.027-14-11-20
eCl@ss 9.027-14-11-20
ETIM 9.0EC000897
ETIM 8.0EC000897
ECCNNO US CLASSIFICATION
PU (SPU)50 pcs
Packaging typebox
Country of originDE
GTIN4055143874236
Customs tariff number85369010000
RoHS Compliance StatusCompliant,No Exemption
Ratings perIEC/EN 60947-7-1
Rated voltage (III / 3)400V
Rated impulse voltage (III / 3)6kV
Rated current16A
Legend (ratings)(III3) ≙ Overvoltage category IIIPollution degree 3
Power loss, per pole (potential)0.341W
Rated current IN for specified power loss16A
ParameterValue
Resistance value for specified, current-dependent power loss0.001Ω
Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section2.5 mm2
Solid conductor0.25 4 m㎡/ 22 12 AWG
Solid conductor; push-in termination0.75 4 m㎡/ 18 12 AWG
Fine-stranded conductor0.25 4 m㎡/ 22 12 AWG
Fine-stranded conductor; with insulated ferrule0.25 2.5 m㎡/ 22 14 AWG
Fine-stranded conductor; with ferrule; push-in termination1 2.5 m㎡/ 18 14 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length10 12 mm / 0.39 0.47 inches
Wiring directionFront-entry wiring
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed