- 855-305/200-501
WAGO 855-305/200-501 is a closed inductive single-conductor current transformer for AC current measurement. Primary rated current is 200 A with a 5 A secondary, 5 VA rated power, accuracy class 1, and rated frequency 50 to 60 Hz. The measurement conductor feedthrough is Ø 26 mm. Rated continuous thermal current is 1.2 x IN; rated short-time thermal current is 60 x IN for 1 s, maximum 100 kA for 1 s. Highest voltage for equipment Um is AC 1.2 kVrms. Test voltage is AC 6 kV at 50 Hz for 1 min. Insulation class E. Dimensions are 60 mm wide, 80.9 mm high, and 52 mm deep; weight 324 g. Operation is -5 to +50 °C, storage -25 to +70 °C, maximum operating altitude 1000 m. Connection uses CAGE CLAMP; strip length 9 to 10 mm. CE marked; EN 61869-1.
- 855-305/200-509
WAGO 855-305/200-509 closed current transformer for current measurement, with 200 A primary rated current and 5 A secondary rated current. Accuracy class 0.5, rated power Sr 5 VA, rated frequency 50 … 60 Hz. Rated continuous thermal current Icth is AC 1.2 x IN; rated short-time thermal current Ith is 60 x IN/1 s (max. 100 kA/1 s). Overcurrent limiting factor is FS5/FS10 (type dependent; see type plate inscription). Test voltage AC 6 kV, 50 Hz, 1 min; highest voltage for equipment Um AC 1.2 kVrms. Feedthrough for measurement conductor Ø 26 mm. CAGE CLAMP connection, strip length 9 10 mm, solid and fine-stranded conductors 0.08 4 mm2 (28 12 AWG). Dimensions 60 x 80.9 x 52 mm, weight 230 g. Insulation class E. Operating temperature -5 … +50 °C, storage -25 … +70 °C, maximum operating altitude 1000 m. Conforms to EN 61869-1, CE marked.
- 855-305/250-501
WAGO 855-305/250-501 is a closed current transformer for current measurement, with a 250 A primary rated current and 5 A secondary rated current. Rated power is 5 VA and accuracy class is 1. Rated frequency is 50 to 60 Hz. The measurement conductor feedthrough is Ø 26 mm. Rated continuous thermal current is 1.2 x IN; rated short-time thermal current is 60 x IN/1 s (max. 100 kA/1 s). Test voltage is AC 6 kV at 50 Hz for 1 min, and highest voltage for equipment is AC 1.2 kVrms. Dimensions are 60 mm width, 80.9 mm height, and 52 mm depth, with 333 g weight. Connection uses CAGE CLAMP®. Operating ambient temperature is -5 to +50 °C. Conformity marking: CE. Standards/specifications: EN 61869-1.
- 855-305/250-509
WAGO 855-305/250-509 signal conditioner in a closed current transformer mounting type. It provides a Ø 26 mm feedthrough for the measurement conductor. Electrical specifications include a test voltage of AC 6 kV at 50 Hz for 1 min and a highest voltage for equipment Um of AC 1.2 kVrms. Insulation class E. Dimensions are 60 mm width, 80.9 mm height, and 52 mm depth, with a weight of 230 g. Operating ambient temperature is -5 to +50 °C; storage ambient temperature is -25 to +70 °C. Maximum operating altitude is 1000 m.
- 855-305/300-501
WAGO 855-305/300-501 is a closed current transformer for current measurement. Primary rated current is 300 A with a 5 A secondary rated current, rated power 5 VA, and accuracy class 1. Rated frequency is 50 to 60 Hz. Rated continuous thermal current Icth is 1.2 x IN; rated short-time thermal current Ith is 60 x IN/1 s (max. 100 kA/1 s). The overcurrent limiting factor is FS5/FS10 (type dependent; see type plate inscription). The measurement conductor feedthrough is Ø 26 mm. Dimensions are 60 mm width, 80.9 mm height, and 52 mm depth; weight is 230 g. Test voltage is AC 6 kV, 50 Hz, 1 min. Highest voltage for equipment Um is AC 1.2 kVrms. Insulation class is E. Conformity marking is CE; standards/specifications include EN 61869-1.
- 855-305/300-509
WAGO 855-305/300-509 is a closed current transformer for current measurement. Primary rated current is 300 A and secondary rated current is 5 A, with rated power Sr of 5 VA and accuracy class 0.5. Rated frequency is 50 to 60 Hz. The measurement conductor feedthrough is Ø 26 mm. Rated continuous thermal current Icth is AC 1.2 x IN; rated short-time thermal current Ith is 60 x IN / 1 s (max. 100 kA / 1 s). Highest voltage for equipment Um is AC 1.2 kVrms. Test voltage is AC 6 kV at 50 Hz for 1 min. Connection technology is CAGE CLAMP, strip length 9 to 10 mm, for solid and fine-stranded conductors 0.08 to 4 mm² (28 to 12 AWG). Dimensions are 60 mm width, 80.9 mm height, 52 mm depth; weight 230 g. Standards/specifications: EN 61869-1. Conformity marking: CE.
- 855-305/400-1001
WAGO 855-305/400-1001 signal conditioner, a closed current transformer for current measurement. Primary rated current 400 A, secondary rated current 5 A, rated power Sr 10 VA, accuracy class 1, rated frequency 50 … 60 Hz. Rated continuous thermal current Icth 1.2 x IN; rated short-time thermal current Ith 60 x IN/1 s (max. 100 kA/1 s). Overcurrent limiting factor FS5/FS10 (type dependent; see type plate inscription). Highest voltage for equipment Um AC 1.2 kVrms; test voltage AC 6 kV, 50 Hz, 1 min. Measurement conductor feedthrough Ø 26 mm. Insulation class E. CAGE CLAMP connection, strip length 9 10 mm, solid and fine-stranded conductors 0.08 4 mm2 (28 12 AWG). Dimensions 60 mm wide, 80.9 mm high, 52 mm deep; weight 285 g. Ambient temperature -5 … +50 °C operation, -25 … +70 °C storage; operating altitude max. 1000 m. CE marking; EN 61869-1.
- 855-305/500-509
WAGO 855-305/500-509 is a closed current transformer for AC current measurement. Primary rated current is 500 A with a 5 A secondary, rated power 5 VA, and accuracy class 0.5. Rated frequency is 50 to 60 Hz. The measurement conductor feedthrough is Ø 26 mm. Rated continuous thermal current is AC 1.2 x IN; rated short-time thermal current is 60 x IN for 1 s (max. 100 kA for 1 s). Highest voltage for equipment Um is AC 1.2 kVrms, and test voltage is AC 6 kV at 50 Hz for 1 min. Dimensions are 60 mm wide, 80.9 mm high, and 52 mm deep, with 230 g weight. Connection uses CAGE CLAMP; solid and fine-stranded conductors accept 0.08 to 4 mm² (28 to 12 AWG), strip length 9 to 10 mm. Operating ambient temperature is -5 to +50 °C. Standards/specifications: EN 61869-1.