- 769-151/000-002
WAGO 769-151/000-002 is a yellow rail chassis terminal block with one potential and one level, designed for DIN-35 rail mounting in a horizontal orientation. It measures 5 mm wide, 87.5 mm high, and 28.5 mm from the upper DIN-rail edge, and weighs 8.5 g. The main housing is polyamide (PA66), material group I, with a flammability class of V0 per UL94 and a fire load of 0.161 MJ. Ratings per IEC/EN 60947-7-1 are 500 V, 6 kV rated impulse voltage, and 32 A rated current at overvoltage category III and pollution degree 3. Processing temperature is -35 to +85 °C; continuous operating temperature is -60 to +105 °C. Wiring is front-entry. A separator plate (209-191) or 10 mm end stop (249-117) must be placed at the end of a WAGO X-COM-SYSTEM terminal strip. One-conductor angled female plugs cannot be used.
- 769-151/000-004
WAGO 769-151/000-004 is a rail chassis terminal block with one potential and one level, designed for DIN-35 rail mounting in a horizontal orientation. It measures 5 mm wide, 87.5 mm high, and 28.5 mm deep from the upper edge of the DIN rail, and weighs 8.5 g. The main housing is black polyamide (PA66) with a UL94 V0 flammability class and a fire load of 0.222 MJ. Ratings per IEC/EN 60947-7-1 are 500 V rated voltage (III/3), 6 kV rated impulse voltage (III/3), and 32 A rated current. Processing temperature is -35 to +85 °C; continuous operating temperature is -60 to +105 °C. Wiring is front-entry. A separator plate (Item No. 209-191) or 10 mm end stop (Item No. 249-117) must be placed at the end of a WAGO X-COM-SYSTEM terminal strip. 1-conductor angled female plugs cannot be used.
- 769-151/000-005
WAGO 769-151/000-005 is a red rail-mount terminal block for DIN-35 rail, horizontal type, with one level and one potential. It measures 5 mm wide, 87.5 mm high, and 28.5 mm from the upper edge of the DIN-rail. The main housing is polyamide (PA66), flammability class V0 per UL94, material group I, fire load 0.161 MJ, weight 8.5 g. Ratings per IEC/EN 60947-7-1: rated voltage 500 V (III/3), rated impulse voltage 6 kV (III/3), rated current 32 A. Continuous operating temperature is -60 to +105 degrees C; processing temperature is -35 to +85 degrees C. Wiring is front-entry. A separator plate (Item No. 209-191) or 10 mm end stop (Item No. 249-117) must be placed at the end of a WAGO X-COM-SYSTEM terminal strip. 1-conductor angled female plugs cannot be used.
- 769-156
WAGO 769-156 is a gray 2-pin carrier terminal block in the X-COM-SYSTEM product group 18, designed for DIN-35 rail mounting in horizontal orientation. It has one level and one potential, with front-entry wiring and center marking. Dimensions are 5 mm width, 52.5 mm height, and 28.5 mm depth from the upper edge of the DIN-rail. The main housing is polyamide (PA66), flammability class V0 per UL94, material group I, fire load 0.099 MJ, weight 4.5 g. Ratings per IEC/EN 60947-7-1: rated voltage 500 V (III/3), rated impulse voltage 6 kV (III/3), rated current 32 A. Processing temperature -35 to +85 degrees C; continuous operating temperature -60 to +105 degrees C. A separator plate (Item No. 209-191) or 10 mm end stop (Item No. 249-117) must be placed at the end of a WAGO X-COM-SYSTEM terminal strip.
- 769-163/769-313
WAGO 769-163/769-313 rail chassis terminal block, gray, horizontal design, 1 level, 6 poles, 6 potentials. Mounts on DIN-35 rail; width 16.1 mm, height 87.5 mm, depth from upper DIN-rail edge 28.5 mm. Rated voltage (III / 3) 400V, rated impulse voltage (III / 3) 6kV, rated current 16A. Housing is Polyamide (PA66), flammability class V0 per UL94, fire load 0.569MJ, weight 25.4g. Processing temperature -35 to +85 °C; continuous operating temperature -60 to +105 °C. Front-entry wiring, center marking. A separator plate (Item No. 209-191) or a 10 mm end stop (Item No. 249-117) must be placed at the end of a WAGO X-COM-SYSTEM terminal strip. 2-conductor female plugs cannot be used.
- 769-165/769-313
WAGO rail chassis terminal block, display model 769-165/769-313, in the X-COM-System product group 18. It has 10 poles, 10 potentials, one level, and front-entry wiring in a horizontal design for DIN-35 rail mounting. Rated voltage is 400 V (III / 3) and rated current is 16 A, with rated impulse voltage 6 kV (III / 3). Dimensions are 26.1 mm wide, 87.5 mm high, and 28.5 mm deep from the upper edge of the DIN rail. The gray polyamide (PA66) housing is UL94 V0 rated. Processing temperature is -35 to +85 °C; continuous operating temperature is -60 to +105 °C. A separator plate (Item No. 209-191) or 10 mm end stop (Item No. 249-117) must be placed at the end of a WAGO X-COM-SYSTEM terminal strip. Two-conductor female plugs cannot be used.
- 769-171
WAGO 769-171 rail chassis terminal block, gray, horizontal design, for DIN-35 rail mounting. It has one level, one potential, two clamping units, and two connection points, with CAGE CLAMP connection technology and front-entry wiring. Connectable conductor material is copper; nominal cross-section is 4 mm2 / 12 AWG, with solid and fine-stranded conductors accepted from 0.08 to 4 mm2 / 28 to 12 AWG. Strip length is 8 to 9 mm / 0.31 to 0.35 inches. Dimensions are 5 mm width, 87.5 mm height, and 28.5 mm depth from the upper DIN-rail edge. Housing is polyamide (PA66), UL94 V0. Ratings per IEC/EN 60947-7-1: 500 V, 6 kV impulse, 32 A, overvoltage category III / pollution degree 3.
- 769-171/000-006
WAGO 769-171/000-006 is a blue, single-level rail chassis terminal block for DIN-35 rail mounting, horizontal design, 5 mm wide. It uses CAGE CLAMP connection with two connection points and an operating tool actuation, accepts copper conductors from 0.08 to 4 mm² (28 to 12 AWG), and has a nominal cross-section of 4 mm² / 12 AWG with 8 to 9 mm strip length. Ratings per IEC/EN 60947-7-1: 500 V rated voltage (III/3), 6 kV rated impulse voltage, 32 A rated current. Housing is polyamide PA66, flammability class V0 per UL94. Processing temperature -35 to +85 °C; continuous operating temperature -60 to +105 °C. A separator plate (209-191) or 10 mm end stop (249-117) is required at the end of a WAGO X-COM-SYSTEM terminal strip. 1-conductor angled female plugs cannot be used.