Industrial Automation Parts. Prompt replies from real people.

WAGO 231-576/108-000 Male Header

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the WAGO 231-576/108-000?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 231-576/108-000 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
231-576/108-000
Material Number
—
Manufacturer
WAGO
Product ID
39746

Get a Free Quote

Request pricing and availability for 231-576/108-000.

More parts to source? Send your whole list in one enquiry

Key specifications

Anti-rotation protection
Yes
Weight
6.8g
Rated voltage (III / 3)
250V
Rated impulse voltage (III / 3)
4kV
Rated current
16A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Pole Count and Configuration: 16-pole male THT header for PCB mounting with in-line solder pin arrangement and one solder pin per potential
  2. Pin Spacing and Dimensions: 5.08 mm pin spacing, 91.28 mm width, 12.2 mm height, 8.4 mm height from surface, 12 mm depth
  3. Electrical Ratings: 16 A rated current, 320 V rated voltage (III/2), 250 V rated voltage (III/3), 630 V nominal voltage (II/2), 4 kV rated impulse/surge voltage
  4. Materials and Temperature Range: Polyamide (PA66) insulation, electrolytic copper contacts with tin plating, UL94 V0 flammability class, -60 to +100 °C limit temperature range
  5. Mounting and Connection Features: Angled design with threaded flange locking, variable coding, anti-rotation protection, no mismating protection, mating direction 0° to PCB
  6. Safety Information: Connectors without breaking capacity per DIN EN 61984, must not be connected or disconnected when live or under load, circuit design should ensure touchable header pins are not live when unmated
231-576/108-000

Product Information

Technical Specifications

Specifications for 231-576/108-000

ParameterValue
Safety informationTheMCS MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated.
Variants:Other pole numbers
Total number of potentials16
Number of connection types1
Number of levels1
Pin spacing5.08 mm / 0.2 inches
Width91.28 mm / 3.594 inches
Height12.2 mm / 0.48 inches
Height from the surface8.4 mm / 0.331 inches
Depth12 mm / 0.472 inches
Solder pin length3.8mm
Solder pin dimensions1.2 x 1.2 mm
Drilled hole diameter with tolerance1.7(+0.1)mm
Variable codingYes
Anti-rotation protectionYes
Contact type (pluggable connector)Male connector/plug
Connector (connection type)for PCB
Mismating protectionNo
Plugging without loss of pin spacingNo
Mating direction to the PCB0°
Locking of plug-in connectionThreaded flange
PCB contactTHT
Solder pin arrangementover the entire male connector (in-line)
Number of solder pins per potential1
Note (material data)Information on material specifications can be found here
Colororange
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Contact materialElectrolytic copper (ECu)
Contact platingTin
Fire load0.101MJ
Weight6.8g
Limit temperature range-60 … +100 °C
Processing temperature-35 … +60 °C
Product Group3 (Multi Conn. System)
eCl@ss 10.027-44-04-02
eCl@ss 9.027-44-04-02
ETIM 9.0EC002637
ETIM 8.0EC002637
ECCNNO US CLASSIFICATION
PU (SPU)50 pcs
Packaging typebox
Country of originPL
GTIN4045454845513
Customs tariff number8536694040
CAS-No.7439-92-1
REACH Candidate List SubstanceLead
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)305691e8-4b1d-4ebe-aea2-442f818987ae
SCIP notification number (Belgium)6d804d05-5215-4185-b1c7-67480188b241
SCIP notification number (Bulgaria)c51326ac-13a1-4a65-9c25-8ac382e942f8
SCIP notification number (Czech Republic)480a8d94-cceb-4ad0-a5d8-c0fbbb558037
SCIP notification number (Denmark)2a6bda2b-a493-4670-a088-2ea10209eb64
ParameterValue
SCIP notification number (Finland)6705cdf0-f397-4ce3-a52c-b96d73aaf892
SCIP notification number (France)47bf53b4-2128-4829-ac9d-f9daf25ab337
SCIP notification number (Germany)c1dec684-2974-41f9-a84d-22ec70088051
SCIP notification number (Hungary)8ba08582-6b74-4ea1-82f9-df0764313655
SCIP notification number (Italy)acdd86ac-b69e-4b28-8c4c-2bf42ec624a3
SCIP notification number (Netherlands)f9ac1edc-c222-47cd-acf7-9e7a697d3348
SCIP notification number (Poland)ef65033b-0173-4d31-9976-a5183fdb3751
SCIP notification number (Romania)34a1b230-529d-4ae3-92d2-e8e7441f3e1a
SCIP notification number (Sweden)c59976f6-4d89-4441-8c7f-5ca79d8002a1
Ratings perIEC/EN 60664-1
Rated voltage (III / 3)250V
Rated impulse voltage (III / 3)4kV
Rated voltage (III/2)320V
Rated surge voltage (III/2)4kV
Nominal voltage (II/2)630V
Rated surge voltage (II/2)4kV
Rated current16A
Legend (ratings)(III2) ≙ Overvoltage category IIIPollution degree 2
Approvals perCSA
Rated voltage UL (Use Group B)300V
Rated current UL (Use Group B)15A
Rated voltage UL (Use Group D)300V
Rated current UL (Use Group D)10A
Rated voltage (UL 1977)600V
Rated current UL 197715A
Rated voltage CSA (Use Group B)300V
Rated current CSA (Use Group B)15A
Rated voltage CSA (Use Group D)300V
Rated current CSA (Use Group D)10A
Number of poles16
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp