Industrial Automation Parts. Prompt replies from real people.

WAGO 2007-8821 Rail Chassis Terminal Blocks

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the WAGO 2007-8821?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the WAGO 2007-8821 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
2007-8821
Material Number
—
Manufacturer
WAGO
Product ID
39706

Get a Free Quote

Request pricing and availability for 2007-8821.

More parts to source? Send your whole list in one enquiry

Key specifications

Weight
27.8g
Rated voltage (III / 3)
500V
Rated impulse voltage (III / 3)
6kV
Rated current
30A
Rated current IN for specified power loss
30A
Frequency
f1= 5 Hz to f2= 150 Hz
See all specifications

Product Highlights

  1. Mounting Type: DIN-35 rail mount
  2. Conductor Configuration: 2-conductor configuration for disconnect and test applications
  3. Jumper Receptacle: Receptacle for adjacent jumper with switch lever
  4. Test Plug Compatibility: Compatible with 4 mm Ø test plugs
  5. Application: Suitable for current transformer circuits
  6. Clamping Units: 2
  7. Potentials: Total number of potentials 2
  8. Levels: 1 level
  9. Jumper Slots: 2 jumper slots
  10. Dimensions: Width 8 mm (0.315 inches), height 99.6 mm (3.921 inches), depth from upper-edge of DIN-rail 65.3 mm (2.571 inches)
  11. Housing Material: Polyamide (PA66), flammability class V0 per UL94, color gray
  12. Temperature Range: Processing temperature -35 to +85 °C, continuous operating temperature -60 to +105 °C
2007-8821

Product Information

Technical Specifications

Specifications for 2007-8821

ParameterValue
Clamping units2
Total number of potentials2
Number of levels1
Number of jumper slots2
Width8 mm / 0.315 inches
Height99.6 mm / 3.921 inches
Depth from upper-edge of DIN-rail65.3 mm / 2.571 inches
Mounting typeDIN-35 rail
Marking levelCenter/side marking
Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.418MJ
Weight27.8g
Test socket colororange
Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C
Product Group22 (TOPJOB S)
eCl@ss 10.027-14-11-26
eCl@ss 9.027-14-11-26
ETIM 9.0EC000902
ETIM 8.0EC000902
ECCNNO US CLASSIFICATION
PU (SPU)20 pcs
Packaging typebox
Country of originCN
GTIN4055143074889
Customs tariff number8536904000
CAS-No.7439-92-1
REACH Candidate List SubstanceLead
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c)
SCIP notification number (Austria)1e2c4f68-0c80-4f7f-b4d2-ef9b6ed3f735
SCIP notification number (Belgium)1a46df3e-2ff6-4cf3-a263-340ef76fa1f1
SCIP notification number (Bulgaria)72f5ce78-1f67-471a-94a3-5898375f14ad
SCIP notification number (Czech Republic)ad5734e3-cdb1-429e-8734-a0ee4cd49658
SCIP notification number (Denmark)b401e4ad-1620-4947-b7de-3f25977d8bb1
SCIP notification number (Finland)579c56ae-46b0-4b84-942e-7623c8338835
SCIP notification number (France)a4ec1bfd-c70f-4a69-b65f-bdebdedcbd5b
SCIP notification number (Germany)c074da76-1734-4521-a06a-664455df075b
SCIP notification number (Hungary)7c7aea40-b04a-49a6-9b36-bb658cda7ee1
SCIP notification number (Italy)97ddee9e-6f84-4304-abef-21c95eabb33d
SCIP notification number (Netherlands)3d7fc2ee-5b30-4782-8d24-56b6e1c59f55
SCIP notification number (Poland)57bafb00-40d2-41d5-9b04-7c3ca60febb1
SCIP notification number (Romania)201ddf09-009d-457f-aa41-ec1c2f19a211
SCIP notification number (Sweden)b67a192b-2617-4193-a205-27932d31da00
Ratings perIEC/EN 60664-1
Rated voltage (III / 3)500V
Rated impulse voltage (III / 3)6kV
Rated current30A
Legend (ratings)(III3) ≙ Overvoltage category IIIPollution degree 3
ParameterValue
Approvals perCSA 22.2 No 158
Rated voltage UL (Use Group B)300V
Rated current UL (Use Group B)30A
Rated voltage UL (Use Group C)300V
Rated current UL (Use Group C)30A
Rated voltage UL (Use Group D)300V
Rated current UL (Use Group D)10A
Rated voltage CSA (Use Group B)300V
Rated current CSA (Use Group B)30A
Rated voltage CSA (Use Group C)300V
Rated current CSA (Use Group C)30A
Rated voltage CSA (Use Group D)300V
Rated current CSA (Use Group D)10A
Power loss, per pole (potential)0.702W
Rated current IN for specified power loss30A
Resistance value for specified, current-dependent power loss0.001Ω
Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section6 mm2 / 10 AWG
Solid conductor0.5 10 m㎡/ 20 8 AWG
Solid conductor; push-in termination1 10 m㎡/ 14 8 AWG
Fine-stranded conductor0.5 10 m㎡/ 20 8 AWG
Fine-stranded conductor; with insulated ferrule0.5 6 m㎡/ 20 10 AWG
Fine-stranded conductor; with uninsulated ferrule1.5 6 m㎡/ 16 10 AWG
Fine-stranded conductor; with ferrule; push-in termination2.5 6 m㎡/ 16 10 AWG
Strip length13 15 mm / 0.51 0.59 inches
Wiring directionFront-entry wiring
Test specification <br/>Railway applications <br/>Rolling stock <br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure <br/>Railway applications <br/>Rolling stock equipment <br/>Shock and vibration testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Installation locationService life test, Category 1, Class A/B
Function test with noise-like vibrationTest passed according to Section 8 of the standard
Frequencyf1= 5 Hz to f2= 150 Hz
Acceleration5g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Monitoring for contact faults/interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like vibrationTest passed according to Section 9 of the standard
Extended test scope: Monitoring for contact faults/interruptionsPassed
Extended test scope: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock formHalf sine
Shock duration30 ms
Number of shocks per axis3 pos. und 3 neg.
Vibration and shock stress for rolling stock equipmentPassed

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp