- 2206-1401
WAGO 2206-1401 rail chassis terminal block for Ex e II applications. It provides side and center marking for identification and uses push-in CAGE CLAMP connections. The terminal block is intended for mounting on a rail.
- 2206-1404
WAGO 2206-1404 rail chassis terminal block rated 57 A and 800 V, made of polyamide 6.6. The 2206-1404 is a rail chassis terminal block from WAGO with a 57 A current rating, an 800 V voltage rating, and a polyamide 6.6 housing.
- 2206-1407
WAGO 2206-1407 rail chassis terminal block with 4-conductor connection and push-in CAGE CLAMP technology. The green-yellow housing identifies it as a ground conductor terminal block. It terminates four conductors in a single rail-mounted chassis block.
- 2206-1612
WAGO 2206-1612 rail chassis terminal block, orange, with two clamping units on one level and one potential. It mounts on DIN-35 rail and uses push-in CAGE CLAMP connection with push-button actuation for copper conductors. Nominal cross-section is 6 mm²; solid and fine-stranded conductors accept 0.5–10 mm² (20–8 AWG), with push-in termination from 2.5 mm². Strip length is 13–15 mm, front-entry wiring. Dimensions: 7.5 mm wide, 96.3 mm high, 59 mm depth from the DIN-rail upper edge. Housing is polyamide PA66, UL94 V0, fire load 0.476 MJ, weight 25 g. Ratings per IEC/EN 60947-7-3: 800 V, 8 kV impulse, 10 A, overvoltage category III, pollution degree 3. Fuse receptacle pivoting for 5 x 20 mm cylindrical fuse.
- 2206-1621
WAGO 2206-1621 is a gray DIN-35 rail terminal block with a pivoting fuse holder for cylindrical 5 x 30 mm fuses. It has one level, one potential, and two clamping units using Push-in CAGE CLAMP connection with push-button actuation. Dimensions are 7.5 mm wide, 96.3 mm high, and 59 mm from the DIN-rail upper edge. The housing is polyamide (PA66), flammability class V0 per UL94, with an orange actuator and 24.9 g weight. Rated per IEC/EN 60947-7-3 at 800 V (III/3), 8 kV impulse, and 10 A; electrical ratings are given by the fuse. CSA 22.2 No 158 ratings are 600 V and 15 A for Use Groups B and C. Nominal cross-section is 6 mm2; strip length 13 to 15 mm.
- 2206-1621/1000-541
WAGO 2206-1621/1000-541 is a gray 2-conductor fuse terminal block for DIN-35 rail mounting, with a pivoting fuse holder for cylindrical 5 x 30 mm fuses and a push-button actuator. It has one level, one potential, and two clamping units, measuring 7.5 mm wide, 96.3 mm high, and 59 mm deep from the DIN-rail upper edge. Connection uses Push-in CAGE CLAMP® technology with front-entry wiring, nominal cross-section 6 mm², strip length 13 to 15 mm, and copper conductors. Electrical ratings per IEC/EN 60947-7-3 are 800 V, 8 kV impulse, and 10 A. The blown-fuse LED indication operates at 12 to 30 V. Housing is polyamide (PA66), UL94 V0, operating from -60 to +50 °C.
- 2206-1621/1000-859
WAGO rail chassis terminal block 2206-1621/1000-859, gray, with orange push-button actuation and a pivoting fuse receptacle for a cylindrical fuse, 5 x 30 mm. It has one level, one potential, and two clamping units on a DIN-35 rail, with front-entry Push-in CAGE CLAMP connection for copper conductors. Nominal cross-section is 6 mm2; solid and fine-stranded conductors accept 0.5 to 10 mm2 (20 to 8 AWG), and strip length is 13 to 15 mm. Dimensions are 7.5 mm wide, 96.3 mm high, and 59 mm from the DIN-rail upper edge. Ratings per IEC/EN 60947-7-3: 800 V, 8 kV impulse, 10 A. Housing is polyamide (PA66), UL94 V0. Operating temperature is -60 to +50 degrees C.
- 2206-1621/1000-867
WAGO 2206-1621/1000-867 is a gray 2-conductor fuse terminal block with a pivoting fuse receptacle for cylindrical fuses measuring 5 x 30 mm. It has 2 clamping units, 1 potential, and 1 level, and mounts on DIN-35 rail. Dimensions are 7.5 mm wide, 96.3 mm high, and 59 mm deep from the upper edge of the DIN rail. Connection uses Push-in CAGE CLAMP technology with push-button actuation for copper conductors, nominal cross-section 6 mm2, strip length 13 to 15 mm, front-entry wiring. The housing is polyamide PA66, flammability class V0 per UL94. Ratings per IEC/EN 60947-7-3 are 800 V, 8 kV impulse, and 10 A. Operation status and blown fuse indication are 120 V.